DIN 5034-3-2007 Daylight in interiors - Part 3 Calculation《室内日光照明 第3部分 计算》.pdf
《DIN 5034-3-2007 Daylight in interiors - Part 3 Calculation《室内日光照明 第3部分 计算》.pdf》由会员分享,可在线阅读,更多相关《DIN 5034-3-2007 Daylight in interiors - Part 3 Calculation《室内日光照明 第3部分 计算》.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、February 2007DEUTSCHE NORMDIN-Normenausschuss Lichttechnik (FNL)DIN-SprachendienstEnglish price group 11No part of this translation may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale f
2、or German Standards (DIN-Normen).ICS 91.160.10!%Ae4“2306617www.din.deDDIN 5034-3Daylight in interiors Part 3: Calculation,English translation of DIN 5034-3:2007-02Tageslicht in Innenrumen Teil 3: Berechnung,Englische bersetzung von DIN 5034-3:2007-02Lumire naturelle lintrieur Partie 3: Calculation,T
3、raduction anglaise de DIN 5034-3:2007-02SupersedesDIN 5034-3:1994-09www.beuth.deDocument comprises 18 pages09.15 DIN 5034-3:2007-02 2 A comma is used as the decimal marker. Contents Page Foreword 3 1 Scope 4 2 Normative references 4 3 Structural geometric relationships for windows 5 3.1 General 5 3.
4、2 Daylight factor 5 3.3 Room parameters 5 3.4 Window dimensions 6 3.5 Geometric parameters for obstructions 8 3.6 Angular parameters for windows and obstructions 9 3.6.1 Window angle .9 3.6.2 Obstruction angle 9 3.7 Reduction factors . 10 3.8 Reflectances and window factors . 11 4 Calculation of the
5、 daylight factor for rooms with windows . 13 4.1 Components 13 4.2 Consideration of reduction factors . 13 4.3 Determination of the sky component DHr14 4.4 Determination of the externally reflected component DVr. 14 4.5 Determination of the internally reflected component DRr14 4.6 Determination of t
6、he daylight factor in rooms with diffusing glazing . 15 5 Average daylight factor for rooms with rooflights 15 6 Period of exposure to sunlight 15 7 Periods of use and relative annual period of use 15 8 Usable luminous exposure and relative usable luminous exposure 16 9 Solar gain . 17 Bibliography
7、. 18 Figures Figure 1 Geometric parameters of a window 7 Figure 2 Geometric parameters for obstructions .8 Figure 3 Determination of the window width angle . 12 Figure 4 Components of the daylight factor 13 Table Table 1 Relation between reduction factor k2and extent of dirt load (default values, se
8、e DIN 5034-1) 10 DIN 5034-3:2007-02 3 Foreword This standard has been prepared by the Normenausschuss Lichttechnik (FNL) (Lighting Technology Standards Committee). DIN 5034 consists of the following parts, under the general title Daylight in interiors: Part 1: General requirements Part 2: Principles
9、 Part 3: Calculation Part 4: Simplified method of determining window sizes in dwellings Part 5: Measurement Part 6: Simplified determination of suitable dimensions for rooflights Amendments This standard differs from DIN 5034-3:1994-09 as follows: a) the standard has been completely revised; b) the
10、standard has been restructured and shortened; c) Tables 3 to 38 are no longer included. Previous editions Supplement 1 to DIN 5034: 1963-11 DIN 5034-3: 1994-09 DIN 5034-3:2007-02 4 1 Scope This standard specifies the method of calculating the expected illuminances, daylight factors, periods of use a
11、nd usable luminous exposures for specific points in interiors, based on the relationships given in DIN 5034-2. It is used to determine whether, given specific window or rooflight dimensions, the minimum values for the daylight factor as specified in DIN 5034-1 are ensured indoors. Of all the various
12、 known calculation methods, this standard recommends a method that has been sufficiently proven in practice, in order to ensure that the results of daylight calculations are comparable. The calculation of radiation from the sun and the sky entering through windows and rooflights is important for inv
13、estigations relating to air-conditioning and economic considerations. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced d
14、ocument (including any amendments) applies. DIN 4710, Statistics on German meteorological data for calculating the energy requirements for heating and air conditioning equipment DIN 5034-1, Daylight in interiors Part 1: General requirements DIN 5034-2, Daylight in interiors Part 2: Principles DIN 50
15、34-6, Daylight in interiors Part 6: Simplified determination of suitable dimensions for rooflights DIN 5035-2, Lighting applications Part 2: Lighting of workplaces DIN 5035-3, Artificial lighting Part 3: Lighting of health care premises DIN 5035-4, Artificial lighting of interiors Part 4: Special re
16、commendations for lighting educational establish-ments DIN 5035-7, Artificial lighting Part 7: Lighting of interiors with visual displays work stations DIN 5036-1, Radiometric and photometric properties of materials Part 1: Definitions, characteristics DIN EN 410, Glass in building Determination of
17、luminous and solar characteristics of glazing DIN EN 12464-1, Light and lighting Lighting of work places Part 1: Indoor work places DIN EN 12665, Light and lighting Basic terms and criteria for specifying lighting requirements DIN 5034-3:2007-02 5 3 Structural geometric relationships for windows 3.1
18、 General All lengths are given in m and all angles are given in degrees. is the elevation angle, the vertex of which lies in the centre of the window. is the width angle, the vertex of which lies at the reference point. is the elevation angle, the vertex of which lies at the reference point. The rel
19、evant dimensions for carrying out the calculation are found in the following clauses. 3.2 Daylight factor The daylight factor D is the ratio of the illuminance at a point on a given plane due to light received directly or indirectly from a sky of known or assumed luminance distribution, to the illum
20、inance on a horizontal plane due to an unobstructed hemisphere of the sky, disregarding the direct sunlight components of both illuminances. NOTE 1 Influences of glazing, dirt, etc. are included. NOTE 2 The contribution of direct sunlight is to be given special consideration in indoor lighting calcu
21、lations. See also DIN EN 12665. 3.3 Room parameters ARis the total area of the room boundary surfaces. AR= 2 (a b + a h + b h) (1) where a is the room depth (for definition, see DIN 5034-1); in rooms with rooflights: room length (see Figure 3); b is the room width (definition, see DIN 5034-1) (see F
22、igure 3); h is the room height; hP is the height of the reference point above the level of the floor. If no further information is given, the reference point lies on a horizontal plane, the reference plane, that is 0,85 m above the finished floor (see Figure 1). P is the reference point at which the
23、 daylight factor D is to be determined. P1, P2are the reference points for determining the daylight factor to achieve sufficient brightness in habitable rooms, and in work rooms with dimensions comparable to those for habitable rooms according to DIN 5034-1 (see Figure 1). The usable area is bordere
24、d by a polyline at a distance of 1 m from the surrounding walls. If not otherwise specified, the usable area lies in the reference plane. DIN 5034-3:2007-02 6 3.4 Window dimensions AFis the area of individual windows (rough opening); =niA1Fis the sum of areas of n windows (rough opening). AF= bF hF(
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DIN503432007DAYLIGHTININTERIORSPART3CALCULATION 室内 日光 照明 部分 计算 PDF

链接地址:http://www.mydoc123.com/p-658236.html