CEPT T S 43-02 E-1987 Signalling System Telephone User Part Plus (TUP+)《信令系统 电话用户部分“+”(TUP+)》.pdf
《CEPT T S 43-02 E-1987 Signalling System Telephone User Part Plus (TUP+)《信令系统 电话用户部分“+”(TUP+)》.pdf》由会员分享,可在线阅读,更多相关《CEPT T S 43-02 E-1987 Signalling System Telephone User Part Plus (TUP+)《信令系统 电话用户部分“+”(TUP+)》.pdf(69页珍藏版)》请在麦多课文档分享上搜索。
1、Recommendation T/S 43-02 (by correspondence, April 1987) SIGNALLING SYSTEM TELEPHONE USER PART “PLUS” (TUP+) Recommendation proposed by Working Group T/WG 11 “Signalling, Protocols and Switching” (SPS) Text of the Recommendation adopted by the “Telecommunications” Commission: “The European Conferenc
2、e of Postal and Telecommunications Administrations, considering - that CCITT Recommendations 4.721-4.725 i to 5 Red Book define the Telephone User Part, - that there are a number of options and points requiring further specification in Recommendations 4.721-4.724 u1 to 41, - that the interconnection
3、 of ISDNs in Europe is an important requirement for European Administrations (see GAP report of the EEC), recommends that European Administrations who wish to interconnect ISDNs, apply the following recommendations.” INTRODUCTION This Recommendation called the Telephone User Part “Plus” (TUP+) is a
4、revised version of CCITT Recommenda- tions 4.721-4.724 (Telephone User Part). In particular, throughout the text, references and figure numbers are maintained as in the CCITT Red Book. Note. 4.72% is not included. The Recommendations are dened for use between international gateways. The interworking
5、 between this Recom- mendation, and National signalling systems is the responsibility of the Administrations concerned. This Recommendation satisfies the requirements laid down in the GAP report Phase 1 only. Note. References to 4.931 q in this Recommendation areintended in a general sense to identi
6、fy the capability of the signalling system on the access side, and do not refer to any specific document. /- Edition of August 15, 1987 CEPT T/S*43-02*E 87 = 232b414 0008079 I W . TIS 43-02 E Page 3 Contents Part I . 4.121 + . 1 . GENERAL 1 2 . TELEPHONE USER PART . 1 3 . MESSAGE TRANSFER PART . 1 F
7、iiiicfioaal Description of the Sigrialling System Telephone User Parti- (TUP+) Part II . 4.722 + . 1 . * SIGNALLINGMESSAGES . 1 2 . SERMCEINFORMATION . 2 3 . SIGNALLING INFORMATION . 2 Part III . 4.723 + . O . EXPLANATORY NOTE . 1 1 . BASIC FORMAT CHARACTEXISTICS . 1 General Firrictiori of Messages
8、or ii) if the range field is coded all zero, the reset of the circuit group has been started and the reset state of each circuit concerned will be reported by the appropriate call, circuit or circuit group supervision signal/message. De 1 et e d r Edition of August 15, 1987 CEPT T/S*43-02*E 87 23264
9、34 0008090 O I O000 Subservice field TIS 43-02 E Part III (Q.723+), Page 1 1111 Service indicator Recommendation Q.723 + FORMAT AND CODES O. 1. 1.1. 1.2. EXPLANATORY NOTE The letter ?F? is used through this Recommendation to indicate the message/code that it appears against is ?Faulty? and depending
10、 on the call state, either the call will be failed and the circuit is cleared or the message/code will be discarded and no action will be taken. BASIC FORMAT CHARACTEXISTICS General The messages are carried on the signalling data link by means of signal units, the format of which is described in Rec
11、ommendation 4.703 i i, paragraph 2.2. The signalling information of each message constitutes the signalling information field of the corresponding signal unit and consists of an integral number of octets. It basically contains the label, the heading code and one or more signals and/or indications. S
12、tructure and function of the label are described in para- graph 2.; the heading codes and detailed message formats are described in paragraph 3. This modified specification is for international use only and not intended for national application. The service information octet The service information
13、octet comprises the service indicator and the subservice field. The service indicator is used to associate signalling information with a particular User Part and is only used with message signal units (see Recommendation 4.704 12, paragraph 12.2.). The information in the subservice field permits a d
14、istinction to be made between national and international signalling messages. The format of the sesvice information octet is shown in Figure 114.723 + . 1.3. 1.3.1. 1.3.2. + First bit transmitted Figure 114.723 + , Service information octet. The following codes are used in the fields of the service
15、information octet: (a) The service indicator is coded 11 11. (b) Subservice field is coded 0000. Format principles The user generated information in the signalling information field is, in general, divided into a number of subfields which may be either of fixed or variable length. For a given messag
16、e type identified by a unique message heading the presence of a given subfield may be either mandatory or optional, The various types of subfields are further defined below. Mandatory sirbjelds Subfields which have been declared mandatory for a given message type appear in all messages of that type,
17、 Optional subjields Subfields which have been declared optional for a given message type only appear when required in messages of that type. The presence or absence of each optional field is indicated by the state of a field indicator located in an indicator field, which in this case is a mandatory
18、subfield. .- / 1 1 ! i 1 Edition of August 15, 1987 _- - ,CEPT T/S*43-02*E 87 H 23264/4 Oa0809/ 2 S TIS 43-02 E Part III (Q.723+), Page 2 1.3.3. 1.3.4. 1.3.5. 1.3.6. 1.3.7. 2. 2.1. 2.2. 2.2.1 * Fixed length subjields Subfields which have been declared fixed length for a given message type contain th
19、e same number of bits in all messages of that type. Variable length subjields For subfields which have been declared variable length for a given message type, the number of bits may vary between messages of that type. The size of a variable length subfield is indicated in an immediately preceding fi
20、xed length subfield in terms of predefined unit such as bits, octets or half-octets. Order of subjeld transmission For a given type of message the various types of subfields are transmitted in the following order: (a) mandatory subfields (b) optional subfields Within each of these two classes, the o
21、rder of subfield transmission is, in general, as follows: 1. 2. variable length subfields. Order of bit transmission Within each defined subfield the information is transmitted least significant bit first. Coding of spare bits Spare bits are coded O unless indicated otherwise. fixed length subfields
22、 (with the exception of the indicator field and subfields indicating the size of a variable length subfield), LABEL General The label is an item of information which forms part of every signalling message and is used by the message routing function at Message Transfer Part level 3 to select the appr
23、opriate signalling route and by the User Part function to identify the particular transaction (e.g. the call) to which the message pertains. In general, label information encompasses an explicit or implicit indication of the message source and destination and, depending on the application, various f
24、orms of transaction identification. For messages which are related to circuits, the transaction is conveniently identified by including the corresponding circuit identity in the label. One standard label format is specified (paragraph 2.2.) for international use. Standard label Label format The stan
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CEPTTS4302E1987SIGNALLINGSYSTEMTELEPHONEUSERPARTPLUSTUP 系统 电话 用户 部分 TUPPDF

链接地址:http://www.mydoc123.com/p-593275.html