1、m 2326434 O006727 O m - G9 24-a2 Page E 1 Recommendation T/R 24-02 (Cannes 1983) DEVICES FOR DETECTING AVALANCHE VICTIMS BY MEANS OF LOW-POWER RADIO EQUIPMENT Recommeudation proposed by “Radiocommunications” Working Group T/WG 3 (R) I Text of the Recommendation adopted by the “Telecommunications” Co
2、mmission : “The European Conference of Postal and Telecommunications Administrations, considering (a) that the rapidly expanding interest in mountaineering leads to a growing need for means of detecting people in danger, in particular avalanche victims, (b) that various types of radio equipment for
3、detecting avalanche victims have been developed, operating on different (c) that harmonising the main technical characteristics would increase the chances of success in sescue operations, (d) that it would therefore be desirable for the administrations to apply common regulations in order to advance
4、 frequencies, the harmonisation of equipment, recommends 1. that the CEPT members encourage the production of radio equipment for detecting avalanche victims in accordance with the technical specifications set out in Annex I, 2. that the CEPT members take the necessary measures with a view to promot
5、ing the use of radio equipment of an approved type in accordance with the specifications set out in Annex I, 3. that the CEPT members take the necessary measures to guarantee the freedom of transport and use of this life-saving equipment.” Edition of September 15, 1988 - h I 2326434 0006728 2 _ T f
6、R 24-02 E Page 3 1. 2. 3. 4. 5. 5.1. 5.2. Annex I SPECIFICATIONS OF EQUIPMENT FOR THE RALHOLOCATION OF AVALANCHE VICTIMS INTRODUCTION - These specifications define the minimum technical characteristics required for transmitters and receivers - These specifications do not guarantee the efficiency of
7、such devices, for example their range, positioning intended for the radiolocation of avalanche victims. accuracy, period of self-sufficient operation, interference sensitivity, etc. GENERAL CONDITIONS The devices must carry a permanently fixed set of instructions. All controls must be marked to indi
8、cate their function or the manner in which they should be used, or both. For the purposes of approval, complete technical documentation must be supplied by the manufacturer. The devices must be permanently marked with an indication of the manufacturer, the model and, where appropriate, the approval
9、number. The equipment must have the following controls: - Adjustment of receiver sensitivity for the purpose of positioning. - A function selector: transmitter-beacon or reception. - It must also be possible to check whether the device is indeed transmitting signals when it is being - The device mus
10、t have a visual or aural control for the purposes of detection and positioning. It would operated as a beacon. be desirable for the device to be able to detect the presence of a jammer. OPERATING FREQUENCY The equipment must operate on either 2,275 Hz or 457 kHz, or on both of these frequencies. It
11、would however be desirable for the receiver at least to be able to operate on both frequencies. CHARACTERISTICS OF TRANSMISSION Transmission may be intermittently cut to economise on consumption. Transmission and cut-off rates must be such as to allow positioning to be carried out without difficulty
12、. The 2,275 Hz signal shall be a pure carrier. The 457 kHz signal shall be a pure or double-sideband amplitude-modulated carrier. TEST CONDITIONS: POWER SUPPLY AND TEMPERATURE Normal and extreme test conditions Approval tests shall be carried out under normal test conditions and, where specified, un
13、der extreme conditions. The test conditions are described below. Test power supplies During approval tests, the power supply of the equipment will be replaced by a test power source able to supply normal and extreme test voltages as specified in paragraphs 5.3.2. and 5.4.2. The internal impedance of
14、 the test power source will be low enough to ensure that its influence on the results is negligible. During tests, the voltage of the power source will be measured at the input terminals of the devices. In the case of equipment with built-in batteries, the test power source will be connected as near
15、 as possible to the battery clips. During tests, the voltage of the power source will be kept at the voltage at the start of each test within a tolerance of f 3 % , Previous page is blank O Edition of September 15, 1988 -. A 232b4L4000b729 4 W TIR 24-02 E Page 4 5.3. 5.3.1. 5.3.2. 5.4. 5.4.1. 5.4.2.
16、 5.5. 5.6. Normal test conditions Normal temperature and tiurnidity conditions During tests, the normal temperature and humidity conditions will correspond to any appropriate combina- tion of temperature and humidity within the following limits: - Temperature: + 15“ C to + 35“ C. - Degree of humidit
17、y: 20% to 75%. Note. In cases where it is impossible to carry out the tests under the conditions described above, a note will be added to the test report indicating the temperatures and degrees of humidity during the tests. Normal test power supply The normal test voltage will be as indicated by the
18、 manufacturer with the agreement of the persons carrying out the tests. Extreme test conditions Extreme temperatures For tests carried out at extreme temperatures, measurements shall be made in accordance with para- graph 5.5. The extreme temperatures shall be: -15C and +40“C. The manufacturer may r
19、equest that the measurements be carried out at - 20“ C or -25“ C instead of Extreme test values for power supply The lower extreme test voltage, in the case of equipment powered by batteries, will be as follows: 1. Leclanch-type batteries: 2. Alkaline batteries: 3. Other types of batteries: In the c
20、ase of equipment using other power sources or able to operate with several power sources, the extreme test voltages shall be as indicated by the manufacturer with the agreement of the persons carrying out the tests. They will be specified in the measurement report. - 15“ C. 0.85 times the nominal vo
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CEPTTR2402E1983DEVICESFORDETECTINGAVALANCHEVICTIMSBYMEANSOFLOWPOWERRADIOEQUIPMENT 通过 功率 无线电 设备 检测 雪崩

链接地址:http://www.mydoc123.com/p-593208.html