CEPT T CD 01-10 E-1985 Engineering Requirements for a 1200 Bit s Duplex Modem for Use on the GSTN《在GSTN上使用的1200比特 秒双工调制解调器工程要求》.pdf
《CEPT T CD 01-10 E-1985 Engineering Requirements for a 1200 Bit s Duplex Modem for Use on the GSTN《在GSTN上使用的1200比特 秒双工调制解调器工程要求》.pdf》由会员分享,可在线阅读,更多相关《CEPT T CD 01-10 E-1985 Engineering Requirements for a 1200 Bit s Duplex Modem for Use on the GSTN《在GSTN上使用的1200比特 秒双工调制解调器工程要求》.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、- CEPT T/CD*OL-LO*E 79 2326434 0003178 O=- (3 TCDO1-10 Page 1 E Recommendation T/CD 01-10 E (Ostende 1979, revised at Cannes 1983) concerning the engineering requirements for a 1,200 bit/s duplex modem for use on the general switched telephone network Recommendation proposed by Working Group T/WG 10
2、 “Data Communications” (CD) Text of the revised Recommendation adopted by the “Telecommunicatioiis” Commission: “The Conference of European Post and Telecommunications Administrations, Considering - that Recommendation T/CD 01-01 contains the text of the Specifications of the general engineering req
3、uirements - that working groupe CD has studied the harmonization of such modems under the auspices of Question CD 1. Recommends - that the attached Specification of engineering requirements for a 1,200 bit/s duplex modem as contained in the Annex to this Recommendation should be taken into account b
4、y ali CEPT Administrations when implementation of such types of equipment is being planned by Administrations.” for data circuit terminating equipment for analogue and digital networks; Administrations are free to stipulate additional requirements, and also which of the optional requirements, if any
5、, are to be provided. Note 1; This specification is subject of continuing study and possible amendment. Note 2; The Annex is an integral part of the Recommendation. e e I Edition of November 30, 1985 CEPT T/CD*OL-LO*E 79 2326434 0003379 2 p T/CD O1 -1 O E Page 3 Annex . Contents Section A . Coinitio
6、n requirements 5 1 . General. 5 2 . Data signalling rates 5 3 . Interfaces 5 4 . Modulation and coding . 6 5 . Scrambler and descrambler . 8 6 . Line signal levels . 9 7 . Testfacilities . 9 8 . Construction . 10 9 . Performance . 10 Section B . Network dependent requirements . 13 1 . General . 13 2
7、 . Fixed compromise equaliser . 13 O 3 . Additional guard tone . 13 Section C . Optional requirements 14 1 . Additional data signalling rates . 14 2 . Additional character size 14 3 . Additional interchange circuits 14 Extended signalling rate range in start-stop mode 14 5 . Controlled carrier opera
8、tion . 14 6 . Additional guard tone . 15 7 . Leased circuit operation 15 4 . CEPT T/CD*OL-LO*E 77 m 2326414 0003L80 7 m 1. 1.1. 1.2. 1.3. 2. 3. 3.1. T/CD O1 -1 O E Page 5 GENERAL This specifications and Recommendation T/CD 01-01 taken together define the facilities required from the modem. The modem
9、 is intended for use on connections on general switched telephone networks. The principal characteristics of this modem are as follows: (a) full duplex operation on 2-wire GSTN circuits; (b) channel separation by frequency division; (c) differential phase shift modulation for each channel with synch
10、ronous line transmission at 6 (nominal) ; (d) inclusion of a scrambler; (e) inclusion of test facilities. O baud The modem shall provide facilities for the transmission of synchronous and start-stop data at 1,200 bit/s. DATA SIGNALLING RATES The data rate transmitted to line shall be 1,200 bit/s 5 0
11、.01% with a modulation rate of 600 baud f0.01%. It shall be possible to configure the modem to accept either: i) synchronous data at 1,200 bit/s 50.01% under the control of circuit 113 or circuit 114; or ii) start-stop data at 1,200 bit/s + 1%, -2.5% with 9 or 10 or 11 bit/character. Selection of mo
12、de and character size shall be by manual means. INTERCHANGE CIRCUITS Table of interchange circuits The interchange circuits are listed in Table 1 shall be provided. Number 102 102a 102b 103 104 105 106 107 108/1 108/2 1 o9 113 114 115 125 140 141 142 Interchange circuit Description Signai ground or
13、common return DTE common return DCE common return Transmitted data Received data Request to send Ready for sending Data set ready Connect data set to line Data terminal ready Data channel received line signal detector Transmitter signal element timing (DTE source) Transmitter signal element timing (
14、DCE source) Receiver signal element timing (DCE source) Calling indicator Loopback/maintenance test Local loopback Test indicator Table 1. Interchange circuits (Note 1). Essential Note 2 Note 2 Note 3 Note 4 Note 4 Note 5 Note 6 Note 6 Note 7 Note I: All essential interchange circuits and any others
15、 which are provided shall comply with the functional and operational requirements of Recommendation T/CD 01-01. All interchange circuits provided shall be properly terminated in the data terminal equipment. Note 2: Interchange circuits 102a and 102b are required where the electrical characteristics
16、defined in Recommendation V.10 are used. Note 3: Some automatic calling equipments are designed to emit a calling tone to line by turning on circuit 105 to the calling modem. The general switched telephone network (GSTN) constant carrier handshake in such that no calling tone will be emitted by the
17、Y.22 modem when used with these equipments. Edition of November 30, 1985 CEPT T/CD*OL-LO*E 232b414 0003LBL O = O0 o1 11 IO T/CD O1 -10 E Page 6 + 90“ O“ + 270“ + 180“ Note 4: This circuit shall be capable of operation as circuit 108/1 or 108/2 depending on its use. For automatic calling, it shall be
18、 used as lOSj2 only. Note 5; When the modem is not operating in a synchronous mode any signals on this circuit shall be disregarded and the data terminal equipment may not have a generator connected. Note 6: When the modem is not operating in a synchronous mode, this circuit shall be clamped to the
19、OFF condition and the data terminal equipment may not terminate the circuit. Note 7; This circuit is for use with the general switched telephone network only. 3.2. Circuits 106 and 109 response times Circuit 106 response times, which are from the application of an ON and OFF condition on circuit 105
20、, shall be: OFF to ON 62ms ON toOFF 62ms Circuit 109 response times shall be: OFF to ON 105 to 205 ms ON to OFF 10 to 24 ms See also Section 4.8. for operating sequences. 4. MODULATION AND CODING 4.1. Carrier and guard tone frequencies The carrier frequencies shall be 1,200I 0.5 Hz for the low chann
21、el and 2,400f 1 Hz for the high channel. A guard tone of 1,800 Hzf20 Hz shall be transmitted at all times when the modem is transmitting in the high channel. The guard tone shall not be transmitted when the modem is transmitting in the low channel. 4.2. Line signal encoding The data stream to be tra
22、nsmitted shall be divided into groups of 2 consecutive bits (dibits). Each dibit shall be encoded as a phase change relative to the phase of the preceding signal element (see Table 2). At the receiver, the dibits shall be decoded and the bits re-assembled in correct order. The left-hand digit of the
23、 dibit is the one occurring first in the data stream as it enters the modular portion of the modem after the scrambler. 1 Dibit value I Phase change I Table 2. Line encoding. Note 1: The phase change is the actual on-line phase shift in the transition region from the centre of one signalling element
24、 to the centre of the following signalling element. 4.3. Spectrum and group delay characteristic After making allowance for the nominal specified compromise equaliser characteristic the transmitted line signal shall have a frequency spectrum equivalent to the square root of raised cosine shaping wit
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- CEPTTCD0110E1985ENGINEERINGREQUIREMENTSFORA1200BITSDUPLEXMODEMFORUSEONTHEGSTN GSTN 使用 1200 比特 双工 调制解调器

链接地址:http://www.mydoc123.com/p-592993.html