BS PD IEC TR 62001-2-2016 High-voltage direct current (HVDC) systems Guidance to the specification and design evaluation of AC filters Performance《高压直流(HVDC)系统 交流滤波器的规格和设计评估指南 性能》.pdf
《BS PD IEC TR 62001-2-2016 High-voltage direct current (HVDC) systems Guidance to the specification and design evaluation of AC filters Performance《高压直流(HVDC)系统 交流滤波器的规格和设计评估指南 性能》.pdf》由会员分享,可在线阅读,更多相关《BS PD IEC TR 62001-2-2016 High-voltage direct current (HVDC) systems Guidance to the specification and design evaluation of AC filters Performance《高压直流(HVDC)系统 交流滤波器的规格和设计评估指南 性能》.pdf(74页珍藏版)》请在麦多课文档分享上搜索。
1、High-voltage direct current (HVDC) systems Guidance to the specification and designevaluation of AC filtersPart 2: PerformancePD IEC/TR 62001-2:2016BSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06National forewordThis Published Document is the UK implementation of IE
2、C/TR 62001- 2:2016. Together with PD IEC/TR 62001-1:2016, PD IEC/TR 62001-3 and PD IEC/TR 62001-4:2016, it supersedes PD IEC/TR 62001:2009 which will be withdrawn on publication of all parts of this series.The UK participation in its preparation was entrusted to TechnicalCommittee PEL/22, Power elec
3、tronics.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions ofa contract. Users are responsible for its correct application. The British Standards Institution 2016.Published by BSI
4、Standards Limited 2016ISBN 978 0 580 91367 9ICS 29.200Compliance with a British Standard cannot confer immunity fromlegal obligations.This Published Document was published under the authority of the Standards Policy and Strategy Committee on 31 August 2016.Amendments/corrigenda issued since publicat
5、ionDate Text affectedPUBLISHED DOCUMENTPD IEC/TR 62001-2:2016IEC TR 62001-2 Edition 1.0 2016-07 TECHNICAL REPORT High-voltage direct current (HVDC) systems Guidance to the specification and design evaluation of AC filters Part 2: Performance INTERNATIONAL ELECTROTECHNICAL COMMISSION ICS 29.200 ISBN
6、978-2-8322-3540-9 Registered trademark of the International Electrotechnical Commission Warning! Make sure that you obtained this publication from an authorized distributor. colourinsidePD IEC/TR 62001-2:2016 2 IEC TR 62001-2:2016 IEC 2016 CONTENTS FOREWORD 5 INTRODUCTION 7 1 Scope .8 2 Normative re
7、ferences 8 3 Current-based interference criteria 8 3.1 General 8 3.2 Determining the necessity for telephone interference limits 9 3.3 Defining telephone interference limits 11 3.3.1 General . 11 3.3.2 Mechanisms of interference . 11 3.3.3 Noise performance coordination levels . 13 3.3.4 Influence o
8、f power transmission lines . 14 3.3.5 Determination of IT limits for a specific project . 19 3.3.6 Pre-existing harmonics and future growth . 23 3.3.7 Recommendations for technical specifications 25 3.4 Consequences for filter design 26 3.5 Telephone infrastructure mitigation options . 27 3.6 Experi
9、ence and examples . 28 3.6.1 General . 28 3.6.2 Review of design requirements 28 3.6.3 Measured current levels of schemes in service . 30 3.6.4 Example of actual telephone interference problems 31 3.6.5 Experience in China, showing no interference problems . 33 3.7 Conclusions 33 4 Field measurement
10、s and verification 34 4.1 Overview 34 4.2 Equipment and subsystem tests 34 4.2.1 General . 34 4.2.2 Fundamental frequency impedance and unbalance measurement . 34 4.2.3 Frequency response curve . 34 4.3 System tests . 35 4.4 Measuring equipment 35 4.4.1 Overview . 35 4.4.2 AC filter energization . 3
11、6 4.4.3 Verification of the reactive power controller 36 4.4.4 Verification of the specified reactive power interchange 36 4.4.5 Verification of the harmonic performance . 37 4.4.6 Verification of audible noise . 39 4.5 In-service measurements 41 4.5.1 General . 41 4.5.2 In-service tuning checks 41
12、4.5.3 On-line monitoring of tuning . 41 4.5.4 Monitoring of IT performance . 41 4.5.5 Measurements of pre-existing harmonic levels for design purposes 41 Annex A (informative) Voltage and current distortion Telephone interference . 42 A.1 Voltage distortion limits for HV and EHV networks . 42 PD IEC
13、/TR 62001-2:2016IEC TR 62001-2:2016 IEC 2016 3 A.1.1 General . 42 A.1.2 Recommended limits for HV or EHV networks 43 A.2 Harmonic current in generators . 45 A.3 Causes of telephone interference 45 A.4 Definition of telephone interference parameters . 47 A.5 Discussion 50 A.6 Coupling mechanism from
14、power-line current to telephone disturbance voltage 51 Annex B (informative) Example of induced noise calculation with Dubanton equations 52 B.1 General 52 B.2 Residual IT . 52 B.3 Balanced IT 53 Annex C (informative) Illustration of the benefit of including a TIF requirement in the technical specif
15、ication. 54 Annex D (informative) Specification of IT limits dependent on network impedance 56 Annex E (informative) The impact of AC network harmonic impedance and voltage level on the filter design necessary to fulfil an IT criterion 60 E.1 General 60 E.2 Assumptions and pre-conditions 61 E.3 Harm
16、onic impedance of AC network 63 E.4 Filter design 65 E.5 Explanation of the difference in impact of relative and absolute performance criteria on required filter Mvar . 67 Bibliography . 68 Figure 1 Conversion factor from positive sequence current at the sending end to positive sequence current at t
17、he receiving end, and input impedance of a 230 kV line, 124 km long, 1000 -m . 21 Figure 2 Conversion factor from positive sequence current to residual current, and input impedance of a 230 kV line, 124 km long, 1 000 -m 21 Figure 3 Simple circuit for calculation of harmonic performance taking into
18、account pre-existing harmonics 23 Figure 4 Converter variables for harmonic performance tests . 37 Figure 5 Example of measurements made during a ramp of the converters . 40 Figure A.1 Contributions of harmonic voltages at different voltage levels in a simple network 42 Figure A.2 C-message and psop
19、hometric weighting factors 46 Figure A.3 Flow-chart describing the basic telephone interference mechanism . 51 Figure D.1 Simplification of the detailed network used for telephone interference simulation . 56 Figure D.2 Induced voltage in telephone circuit vs. network impedance, for unitary current
20、injected . 57 Figure D.3 IT limits as defined for different network impedances 58 Figure E.1 Converter harmonics un-weighted (A) and IT weighted (kA) on 240 kV base . 62 Figure E.2 Converter Mvar absorption versus load . 63 Figure E.3 Impedance sector diagram and RL-equivalent circuit . 64 Figure E.
21、4 Simplified converter/system topology 64 Figure E.5 Simplified circuit including overhead transmission line . 65 PD IEC/TR 62001-2:2016 4 IEC TR 62001-2:2016 IEC 2016 Table 1 Performance thresholds for metallic noise . 14 Table 2 Performance thresholds for longitudinal noise 14 Table 3 Performance
22、thresholds for balance 14 Table 4 Illustrative maximum telephone line length to achieve the North American recommended longitudinal Nglevel, as a function of balanced IT level, earth resistivity and separation distance 17 Table 5 Illustrative maximum telephone line length to achieve the North Americ
23、an recommended longitudinal Nglevel as a function of residual IT level, earth resistivity and separation distance 18 Table 6 Some HVDC schemes Specified telephone interference criteria 29 Table 7 Measured 95 % values of THFF and Ipeof a 600 MW scheme (3 phases) 31 Table 8 Measured 95 % values of THF
24、F and Ipeof a 300 MW scheme (3 phases) 31 Table A.1 Voltage distortion limits from IEEE 519-1992 43 Table A.2 Compatibility levels for harmonic voltages (in percent of the nominal voltage) in LV and MV power systems based on Table 1 of IEC TR 61000-3-6:2008 44 Table A.3 Indicative values of planning
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSPDIECTR6200122016HIGHVOLTAGEDIRECTCURRENTHVDCSYSTEMSGUIDANCETOTHESPECIFICATIONANDDESIGNEVALUATIONOFACFILTERSPERFORMANCE

链接地址:http://www.mydoc123.com/p-588920.html