BS ISO 11631-1999 Measurement of fluid flow - Methods of specifying flowmeter performance《流体流量测量 流量计性能的规定方法》.pdf
《BS ISO 11631-1999 Measurement of fluid flow - Methods of specifying flowmeter performance《流体流量测量 流量计性能的规定方法》.pdf》由会员分享,可在线阅读,更多相关《BS ISO 11631-1999 Measurement of fluid flow - Methods of specifying flowmeter performance《流体流量测量 流量计性能的规定方法》.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS ISO 11631:1998 Measurement of fluid flow Methodsofspecifying flowmeter performance ICS 17.120.01BSISO11631:1998 This British Standard, having been prepared under the directionof the Sector Committeefor Materials and Chemicals, was published underthe authority of the Standards Com
2、mittee and comesinto effect on 15January1999 BSI 06-1999 ISBN 0 580 30767 0 National foreword This British Standard reproduces verbatim ISO11631:1998 and implements it as the UK national standard. This is a new standard, and no other standard is superseded. The UK participation in its preparation wa
3、s entrusted by Technical Committee CPI/30, Measurement of fluid flow in closed conduits, to Subcommittee CPI/30/9, General topics, which has the responsibility to: aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, o
4、r proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. A list of organizations represented on this subcommittee can be obtained on request to its secretary. Cross-references The British Standards which implem
5、ent international or European publications referred to in this document may be found in the BSI Standards Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Find” facility of the BSI Standards Electronic Catalogue. A British Standard does not purpor
6、t to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cov
7、er, pages i and ii, theISO title page, pages ii to iv, pages1 to9 and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover. Amendments issued since publication Amd. No. Date
8、 CommentsBSISO11631:1998 BSI 06-1999 i Contents Page National foreword Inside front cover Foreword iii Text of ISO 11631 1ii blankBSISO11631:1998 ii BSI 06-1999 Contents Page Foreword iii 1 Scope 1 2 Normative reference 1 3 Terms and definitions 1 4 General requirements 5 5 Traceability 5 6 Uncertai
9、nty of flow measurement 5 7 Conditions of use 5 8 Traceability group 6 Annex A (informative) Illustrations of linearity 7 Annex B (normative) Repeatability 8 Bibliography 9 Figure 1 Typical hysteresis loop 3 Figure A.1 Different expressions of linearity 7 Figure A.2 Typical application of independen
10、t linearity 8 Table B.1 Students t values (t 95 ) 9 Descriptors: Flow measurement, flowmeters, measurement characteristics, performance, description.BSISO11631:1998 BSI 06-1999 iii Foreword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodie
11、s (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations,
12、 governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. International Standards are drafted in accordance with the rules given in the ISO
13、/IEC Directives, Part3. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at least75% of the member bodies casting a vote. International Standard ISO11631 was prepared by Tec
14、hnical Committee TC30,Measurement of fluid flow in closed conduits, Subcommittee SC9, General topics. Annex B forms a normative part of this International Standard.Annex A is for information only.iv blankBSISO11631:1998 BSI 06-1999 1 1 Scope This International Standard applies to technical specifica
15、tions and descriptions issued by manufacturers of flowmeters. It specifies methods of describing the performance of any flowmeter, for use in either closed conduits or open channels. It indicates how flowmeters may be classified according to their traceability group, and specifies how manufacturers
16、statements on traceability, quality assurance and conditions of use should be expressed, although further statements may be required for other conditions of use. NOTEThe terms and definitions given in clause3 include a large number of associated terms to encourage common usage of these terms in tech
17、nical specifications. 2 Normative reference The following normative document contains provisions which, through reference in this text, constitute provisions of this International Standard. For dated references, subsequent amendments to, or revisions of, this publication do not apply. However, parti
18、es to agreements based on this International Standard are encouraged to investigate the possibility of applying the most recent edition of the normative document indicated below. For undated references, the latest edition of the normative document referred to applies. Members of ISO and IEC maintain
19、 registers of currently valid International Standards. ISO/TR5168, Measurement of fluid flow Estimation of uncertainty of a flowrate measurement. 3 Terms and definitions For the purposes of this International Standard, the terms and definitions given in ISO5168 apply, adapted where appropriate to re
20、fer specifically to flowmeters and to describe the characteristics of flowmeters. 3.1 accuracy (deprecated) gof a flowmeter ability of a flowmeter to give responses close to a true value NOTEAccuracy is a commonly used term and can include the effects of systematic and random errors, hysteresis, dea
21、dband,etc. Although it is convenient to combine all these errors under the heading of “accuracy”, it is a qualitative term: no numerical value is attached to it, and it is not used in the performance specification of a flowmeter. 3.2 accuracy class class of flowmeters which meets certain metrologica
22、l requirements that are intended to keep errors within specified limits NOTEAn accuracy class is usually denoted by a number or symbol which is adopted by convention and is called the class index. 3.3 bias gof a flowmeter systematic error of the indication of a flowmeter 3.4 calibration set of opera
23、tions which establish, under specified conditions, the relationship between values of quantities indicated by a flowmeter and the corresponding values indicated by a standard of reference NOTE 1The result of a calibration permits either the assignment of values of measurands to the indications or th
24、e determination of corrections with respect to indications. NOTE 2A calibration may also determine other metrological properties, such as the effect of influence quantities. NOTE 3The result of a calibration may be recorded in a document, sometimes called a calibration certificate or a calibration r
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSISO116311999MEASUREMENTOFFLUIDFLOWMETHODSOFSPECIFYINGFLOWMETERPERFORMANCE 流体 流量 测量 流量计 性能 规定 方法 PDF

链接地址:http://www.mydoc123.com/p-583627.html