BS EN 61262-1-1995 Characteristics of electro-optical X-ray image intensifiers for medical electrical equipment - Determination of the entrance field size《医疗电气设备用光电X射线图象增强器的特性 第1部分.pdf
《BS EN 61262-1-1995 Characteristics of electro-optical X-ray image intensifiers for medical electrical equipment - Determination of the entrance field size《医疗电气设备用光电X射线图象增强器的特性 第1部分.pdf》由会员分享,可在线阅读,更多相关《BS EN 61262-1-1995 Characteristics of electro-optical X-ray image intensifiers for medical electrical equipment - Determination of the entrance field size《医疗电气设备用光电X射线图象增强器的特性 第1部分.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS EN 61262-1:1995 IEC1262-1: 1994 Characteristics of electro-optical X-ray image intensifiers for medical electrical equipment Part1: Determination of the entrance field size The European Standard EN61262-1:1994 has the status of a BritishStandardBSEN61262-1:1995 This BritishStanda
2、rd, having been prepared under the directionof the Health and Environment Sector Board (H/-), was published under the authorityof the Standards Boardand comes into effect on 15April1995 BSI 01-2000 The following BSI references relate to the work on this standard: Committee reference HCC/72 Draft for
3、 comment94/501341 DC ISBN 0 580 23590 4 Committees responsible for this BritishStandard The preparation of this BritishStandard was entrusted to Technical Committee HCC/72, Image intensifiers, upon which the following bodies were represented: Association of X-ray Equipment Manufacturers (BEAMA Ltd.)
4、 British Institute of Radiology College of Radiographers Institute of Physical Sciences in Medicine (Ipsm) Amendments issued since publication Amd. No. Date CommentsBSEN61262-1:1995 BSI 01-2000 i Contents Page Committees responsible Inside front cover National foreword ii Foreword 2 Text of EN61262-
5、1 3 List of references Inside back coverBSEN61262-1:1995 ii BSI 01-2000 National foreword This BritishStandard has been prepared by Technical Committee HCC/72 and is the English language version of EN61262-1:1994 Medical electrical equipment Characteristics of electro-optical X-ray image intensifier
6、s Part1Determination of the entrance field size, published by the European Committee for Electrotechnical Standardization (CENELEC). It is identical with IEC1262-1:1994 published by the International Electrotechnical Commission (IEC). It supersedes BS6893:1988, which is withdrawn. Additional informa
7、tion. The following print types are used in this standard. Requirements, with which compliance can be tested, and definitions: inromantype. Explanations, advice, general statements, exceptions and references: insmaller type. Test procedures: in italic type. Terms defined in clause3 of this standard
8、and in Annex A: in SMALL CAPITALS. For the purposes of this BritishStandard, any references to IEC page numbers in the text should be ignored. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct appli
9、cation. Compliance with a British Standard does not of itself confer immunity from legal obligations. Cross-references Publication referred to Corresponding BritishStandard HD501 S1 (IEC788:1984) BS6641:1985 Glossary of medical radiology terms Summary of pages This document comprises a front cover,
10、an inside front cover, pagesi andii, theEN title page, pages2 to8, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover.EUROPEAN STANDARD NORME EURO
11、PENNE EUROPISCHE NORM EN61262-1 September 1994 ICS 11.040.50 Supersedes HD510 S1:1988 Descriptors: Medical electrical equipment, image intensifier, X-ray, entrance field Englishversion Medical electrical equipment Characteristics of electro-optical X-ray image intensifiers Part1:Determination of the
12、 entrance field size (IEC1262-1:1994) Appareils lectromdicaux Caractristiques des intensificateurs lectro-optiques dimage radiologique Partie1: Dtermination de la dimension du champ dentre (CEI1262-1:1994) Medizinische elektrische Gerte Merkmale von elektronenoptischen Rntgenbildverstrkern Teil1: Be
13、stimmung der Eingangsfeldgre (IEC1262-1:1994) This European Standard was approved by CENELEC on 1994-07-05. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alt
14、eration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by
15、translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Denmark, Finland, France, Germany, Greece, Iceland, I
16、reland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and UnitedKingdom. CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassar
17、t 35, B-1050 Brussels 1994 Copyright reserved to CENELEC members Ref. No. EN61262-1:1994 EEN61262-1:1994 BSI 01-2000 2 Foreword The text of document62B(CO)112, as prepared by Sub-Committee62B: Diagnostic imaging equipment, of IEC Technical Committee62: Electrical equipment in medical practice, was s
18、ubmitted to the IEC-CENELEC parallel vote in January1994. The reference document was approved by CENELEC as EN61262-1 on 5July1994. This European Standard replaces HD510 S1:1988 The following dates were fixed: For products which have complied with HD510S1:1988 before1995-07-01, as shown by themanufa
19、cturer or by a certification body, this previous standard may continue to apply for production until2000-07-01. Annexes designated “normative” are part of the body of the standard. Annexes designated “informative” are given only for information. In this standard, Annex A and Annex B are informative
20、and Annex ZA is normative. Contents Page Foreword 2 Introduction 3 1 Scope 3 2 Normative reference 3 3 Terminology 3 3.1 Definitions 3 3.2 Degree of requirements and reading instructions 4 4 Requirements 4 4.1 Test set-up 4 4.2 X-RAY IMAGE INTENSIFIER Operating conditions 4 4.3 Input radiation 4 4.4
21、 TEST DEVICE 4 4.5 Measurement equipment 4 5 Determination of the USEFUL ENTRANCE FIELD SIZE and NOMINAL ENTRANCE FIELD SIZE 4 5.1 Preparation 4 5.2 Measurement 5 5.3 Corrections 5 5.4 Determination 5 6 Presentation of the ENTRANCE FIELD SIZE 5 7 Statement of compliance 5 Annex A (informative) Termi
22、nology Index of terms 6 Annex B (informative) Derivation of the NOMINAL ENTRANCE FIELD SIZE 7 Annex ZA (normative) Other international publications quoted in this standard with the references of the relevant European publications 8 Figure B.1 Geometry of test set-up 7 latest date of publication ofan
23、 identical national standard (dop) 1995-07-01 latest date of withdrawal ofconflicting national standards (dow) 1995-07-01EN61262-1:1994 BSI 01-2000 3 Introduction The ENTRANCE FIELD SIZE of the ELECTRO-OPTICAL X-RAY IMAGE INTENSIFIER can be specified in several ways depending on the specific SED. Ty
24、pically, the ENTRANCE FIELD SIZE is specified as a NOMINAL ENTRANCE FIELD SIZE or as a USEFUL ENTRANCE FIELD SIZE. The SOURCE TO ENTRANCE PLANE DISTANCE (SED) for the NOMINAL ENTRANCE FIELD SIZE is infinite, while the USEFUL ENTRANCE FIELD SIZE is measured at a specific SED, usually one meter. Both
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN6126211995CHARACTERISTICSOFELECTROOPTICALXRAYIMAGEINTENSIFIERSFORMEDICALELECTRICALEQUIPMENTDETERMINATIONOFTHEENTRANCEFIELDSIZE

链接地址:http://www.mydoc123.com/p-577211.html