BS EN 61249-2-39-2013 Materials for printed boards and other interconnecting structures Reinforced base materials clad and unclad High performance epoxide and non-epoxide woven E-gr.pdf
《BS EN 61249-2-39-2013 Materials for printed boards and other interconnecting structures Reinforced base materials clad and unclad High performance epoxide and non-epoxide woven E-gr.pdf》由会员分享,可在线阅读,更多相关《BS EN 61249-2-39-2013 Materials for printed boards and other interconnecting structures Reinforced base materials clad and unclad High performance epoxide and non-epoxide woven E-gr.pdf(28页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationMaterials for printed boards and other interconnecting structuresPart 2-39: Reinforced base materials clad and unclad High performance epoxide and non-epoxide, woven E-glass lami
2、nate sheets of defined flammability (vertical burning test), copper-clad for lead-free assemblyBS EN 61249-2-39:2013National forewordThis British Standard is the UK implementation of EN 61249-2-39:2013. It is identical to IEC 61249-2-39:2012.The UK participation in its preparation was entrusted to T
3、echnical Committee EPL/501, Electronic assembly technology 1 065 mm 1 155 mm; 1 065 mm 1 280 mm; 1 000 mm 1 000 mm; 1 000 mm 1 200 mm. 6.8.2 Tolerances for sheet sizes The size of sheet delivered by the supplier shall not deviate by more than +20/0 mm from the ordered size. 6.9 Cut panels 6.9.1 Cut
4、panel sizes Cut panel sizes shall be, when delivered, in accordance with the purchasers specification. 6.9.2 Size tolerances for cut panels For panels cut to size according to the purchasers specification, the following tolerances for length and width shall apply, as shown in Table 7. Tolerances ind
5、icated as normal shall be in effect unless otherwise specified by in the purchasing specification. Table 7 Size tolerances for cut panels Panel size mm Tolerance requirement mm Normal Close 300 2,0 0,5 300 600 2,0 0,8 600 2,0 1,6 NOTE The specified tolerances include all deviations caused by cutting
6、 the panels. BS EN 61249-2-39:201361249-2-39 IEC:2012 13 6.9.3 Rectangularity of cut panels For panels cut to size according to the purchasers specification, the following requirements for rectangularity shall apply as shown in Table 8. Tolerance indicated as normal shall be in effect unless otherwi
7、se specified in the purchasing specification. Table 8 Rectangularity of cut panels Property Test method IEC 61189-2 Requirement mm/m Normal Close Rectangularity of cut panels 2M23 3 2 7 Non-electrical properties of the base material after complete removal of the copper foil 7.1 Appearance of the die
8、lectric base material The etched specimens shall be inspected to verify that no surface or subsurface imperfections of the dielectric material exceed those shown below. The panels shall be inspected using an optical aid apparatus which provides a minimum magnification of 4X. Referee inspection shall
9、 be conducted at 10X magnification. Lighting conditions of inspection shall be appropriate to the material under inspection or as agreed upon between user and supplier. Surface and subsurface imperfections (such as weave texture, resin starvation, voids, foreign inclusions) shall be acceptable provi
10、ded that the imperfections meet the following: the reinforcement fibres are not cut or exposed; the foreign inclusions are not conductive; the imperfections do not propagate as a result of thermal stress; the foreign inclusions are translucent; opaque foreign fibres are less than 15 mm in length and
11、 average no more than 1,0 per 300 mm 300 mm area; opaque foreign inclusions other than fibres shall not exceed 0,50 mm. Opaque foreign inclusions less than 0,15 mm shall not be counted. Opaque foreign inclusions between 0,50 mm and 0,15 mm shall average no more than two spots per 300 mm 300 mm area;
12、 voids (sealed voids or surface void) have a longest dimension less than 0,075 mm and there should not be more than three voids in a 3,5 mm diameter circle. 7.2 Flexural strength When the laminate is tested in accordance with test method 2M20 of IEC 61189-2, the flexural strength shall be as shown i
13、n Table 9. BS EN 61249-2-39:2013 14 61249-2-39 IEC:2012 Table 9 Flexural strength requirements Property Test method IEC 61189-2 Requirement Flexural strength: Length direction Cross-direction (applicable to sheets 1,0 mm in thickness) 2M20 400 N/mm2300 N/mm2Flexural strength: Length direction Elevat
14、ed temperature (applicable to sheets1,0 mm in thickness) Not specified 7.3 Flammability When the laminate is tested in accordance with test method 2C08 (thickness 0,05 0,3 mm) or method 2C06 (thickness 0,3 3,2 mm) of IEC 61189-2 the flammability shall be as shown in Table 10. The performance labelle
15、d V-0 shall be in effect unless otherwise noted on the purchase order. Table 10 Flammability requirements Property Test method IEC 61189-2 Requirements Designation V-0 Flammability: Flaming combustion time after each application of the flame for each test specimen Total flaming combustion time for t
16、he 10 flame applications for each set of five specimens Glowing combustion time after the second removal of the test flame Flaming or glowing combustion up to the holding clamp Dripping flaming particles that ignite the tissue paper 2C06 10 s 50 s 30 s None None BS EN 61249-2-39:201361249-2-39 IEC:2
17、012 15 7.4 Water absorption When the laminate is tested in accordance with test method 2N02 of IEC 61189-2, the maximum water absorption shall be as shown in Table 11. Table 11 Water absorption requirements Property Test method IEC 61189-2 Thickness mm Requirement % Water absorption 2N02 0,05 Tg) 25
18、0 ppm/C Specific heat capacity 1,25 kJ/ (kgC) Thermal conductivity 0,3 W/(mC) UL temperature index (mechanical) 130 C UL temperature index (electrical) 130 C Maximum operating temperature (MOT) 130 C BS EN 61249-2-39:201361249-2-39 IEC:2012 21 Annex B (informative) Common laminate constructions Tabl
19、e B.1 gives the nominal thicknesses. Table B.1 Thickness Nominal thickness mm Common construction 0,075 1 080 0,080 2 106 0,100 2 106 0,100 2 113 0,100 2 116 0,125 2 116 0,125 2 165 0,125 2 1 080 0,15 2 157 0,15 2 165 0,16 1 500 0,18 7 628 0,18 1 500 0,20 2 2 113 0,20 2 2 116 0,20 7 628 0,25 2 2 116
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN612492392013MATERIALSFORPRINTEDBOARDSANDOTHERINTERCONNECTINGSTRUCTURESREINFORCEDBASEMATERIALSCLADANDUNCLADHIGHPERFORMANCEEPOXIDEANDNONEPOXIDEWOVENEGRPDF

链接地址:http://www.mydoc123.com/p-577173.html