《BS EN 50467-2011 Railway applications Rolling stock Electrical connectors requirements and test methods《轨道交通 全部车辆 电连接器的要求和试验方法》.pdf》由会员分享,可在线阅读,更多相关《BS EN 50467-2011 Railway applications Rolling stock Electrical connectors requirements and test methods《轨道交通 全部车辆 电连接器的要求和试验方法》.pdf(46页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS EN 50467:2011Railway applications Rolling stock Electrical connectors, r e q u i r e m e n t s and test methodsCopyright European Committee for Electrotechnical Standardizatio
2、n Provided by IHS under license with CENELECNot for ResaleNo reproduction or networking permitted without license from IHSBS EN 50467:2011 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 50467:2011. It supersedes DD CLC/TS 50467:2008, which is withdrawn.The UK p
3、articipation in its preparation was entrusted to Technical Committee GEL/9/2, Railway Electrotechnical Applications - Rolling stock.A list of organizations represented on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisi
4、ons of a contract. Users are responsible for its correct application. The British Standards Institution 2012 ISBN 978 0 580 68810 2 ICS 29.120.20; 45.060.01 Compliance with a British Standard cannot confer immunity from legal obligations.This British Standard was published under the authority of the
5、 Standards Policy and Strategy Committee on 31 January 2012.Amendments issued since publicationDate T e x t a f f e c t e dCopyright European Committee for Electrotechnical Standardization Provided by IHS under license with CENELECNot for Resale-,-,-BS EN 50467:2011EUROPEAN STANDARD EN 50467 NORME E
6、UROPENNE EUROPISCHE NORM December 2011 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Management Centre: Avenue Marnix 17, B - 1000 Brussels 2011 CENELEC - All rights of exploitation in
7、any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 50467:2011 E ICS 29.120.30; 45.060.01 Supersedes CLC/TS 50467:2008 + corr. May.2008English version Railway applications - Rolling stock - Electrical connectors, requirements and test methods Applications ferroviaires - Mat
8、riel roulant - Connecteurs lectriques, exigences et mthodes dessai Bahnanwendungen - Fahrzeuge - Elektrische Steckverbinder, Bestimmungen und Prfverfahren This European Standard was approved by CENELEC on 2011-10-10. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which
9、 stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This
10、European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CENELE
11、C members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, S
12、lovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. Copyright European Committee for Electrotechnical Standardization Provided by IHS under license with CENELECNot for Resale-,-,-BS EN 50467:2011EN 50467:2011 2 Contents Foreword . 4 Introduction . 51 Scope . 62 Normative references
13、 . 63 Terms and definitions . 84 Technical information (electrical ratings) 145 Classification . 145.1 General . 145.2 Severity of service conditions in different rolling stock technologies 145.3 Intended use of rolling stock . 145.4 Location of connector on board rolling stock 156 Requirements 176.
14、1 General . 176.2 Marking and identification . 176.3 Provision against incorrect mating (non-intermateable) . 186.4 Protection against electric shock 186.5 Provisions for earthing 186.6 Terminations and connection methods . 186.7 Resistance to ageing 196.8 General design . 196.9 Design of a free con
15、nector 206.10 Interlock 206.11 Degree of protection IP . 206.12 Dielectric strength . 206.13 Mechanical and electrical durability 206.14 Cable strain relief 216.15 Mechanical strength 216.16 Vibration and shock 216.17 Insulation coordination 226.18 Temperature classes 226.19 Temperature rise 226.20
16、Protection against corrosion . 226.21 Electromagnetic compatibility (EMC) requirements . 236.22 Fire behaviour of materials and components . 236.23 Resistance to chemically active substances and to contaminating fluids 236.24 Resistance to ozone . 236.25 Resistance to UV 237 Tests . 247.1 Introducti
17、on . 247.2 Test schedule (EN 60512-1-100 General Applicable publications) 267.3 Tests on raw materials 327.4 Visual examination 327.5 Durability of marking . 337.6 Interlock 337.7 Protection against electric shock 337.8 Temperature rise 337.9 Mechanical operation 347.10 Vibration and shock 347.11 Me
18、asurement of clearances and creepage distances 357.12 Dielectric strength . 357.13 Resistance between accessible metal parts and the protective earthing contact 357.14 Corrosion test . 367.15 Ozone resistance (ISO 1431-1) 367.16 Resistance to UV (EN ISO 4892-2:2006) . 36Copyright European Committee
19、for Electrotechnical Standardization Provided by IHS under license with CENELECNot for Resale-,-,-BS EN 50467:2011 3 EN 50467:2011 7.17 Resistance to fluids (EN 60512-19-3:1997) 36Annex A (informative) Additional characteristics to be agreed by the manufacturer and the user . 37A.1 Additional inform
20、ation to be provided upon request of the user . 37A.2 Information for testing additional to that mentioned above . 38Annex B (normative) Severity of the service conditions in different rolling stock locations . 39Annex C (informative) Severity of the service conditions in different rolling stock loc
21、ations . 40Bibliography 41Figures Figure 1 Typical examples of connections 8Figure 2 Multipole connectors . 10Figure 3 Typical connector locations on board rolling stock . 15Figure 4 Test sample for temperature rise test . 34Tables Table 1 Example of typical connector locations on board rolling stoc
22、k 16Table 2 Preferred number of operating cycles . 21Table 3 Preferred test temperatures . 22Table 3a Lower limiting temperature (LLT) Preferred values 22Table 3b Uper limiting temperature (ULT) Preferred values . 22Table 4 Plan of specimens required for tests . 24Table 5 Mechanical test group A 26T
23、able 6 Service life test group B . 27Table 7 Thermal test group C . 27Table 8 Climatic test group D 28Table 9 Degree of protection, test group E . 29Table 10 Vibration and shock test group F . 30Table 11 Resistance to fluids test group G . 31Table 12 Shielding effectiveness test group H . 32Table 13
24、 Tests on raw materials . 32Table 14 Test voltages 35Table B.1 Minimum severity of service conditions in different rolling stock locations 39Table C.1 Minimum severity of service conditions in different rolling stock locations 40Copyright European Committee for Electrotechnical Standardization Provi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN504672011RAILWAYAPPLICATIONSROLLINGSTOCKELECTRICALCONNECTORSREQUIREMENTSANDTESTMETHODS 轨道交通 全部 车辆

链接地址:http://www.mydoc123.com/p-574954.html