《BS EN 50412-2-1-2005 Power line communication apparatus and systems used in low-voltage installations in the frequency range 1 6 MHz to 30 MHz - Residential commercial and industri.pdf》由会员分享,可在线阅读,更多相关《BS EN 50412-2-1-2005 Power line communication apparatus and systems used in low-voltage installations in the frequency range 1 6 MHz to 30 MHz - Residential commercial and industri.pdf(22页珍藏版)》请在麦多课文档分享上搜索。
1、 g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58used in low-voltage installations in the frequency range 1,6 MHz to 30 MHz Part 2-1: Residential, c
2、ommercial and industrial environment Immunity requirementsThe European Standard EN 50412-2-1:2005 has the status of a British StandardICS 33.120.20; 97.120Power line communication apparatus and systems BRITISH STANDARDBS EN 50412-2-1:2005BS EN 50412-2-1:2005This British Standard was published under
3、the authority of the Standards Policy and Strategy Committee on 12 December 2005 BSI 12 December 2005ISBN 0 580 46927 1The British Standards which implement international or European publications referred to in this document may be found in the BSI Catalogue under the section entitled “International
4、 Standards Correspondence Index”, or by using the “Search” facility of the BSI Electronic Catalogue or of British Standards Online.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Sta
5、ndard does not of itself confer immunity from legal obligations.Summary of pagesThis document comprises a front cover, an inside front cover, the EN title page, pages 2 to 18, an inside back cover and a back cover.The BSI copyright notice displayed in this document indicates when the document was la
6、st issued.Amendments issued since publicationAmd. No. Date CommentsA list of organizations represented on this committee can be obtained on request to its secretary.Cross-referencesenquiries on the interpretation, or proposals for change, and keep UK interests informed; monitor related international
7、 and European developments and promulgate them in the UK.National forewordThis British Standard is the official English language version of EN 50412-2-1:2005.The UK participation in its preparation was entrusted to Technical Committee PEL/205, Mains signalling, which has the responsibility to: aid e
8、nquirers to understand the text; present to the responsible international/European committee any EUROPEAN STANDARD EN 50412-2-1 NORME EUROPENNE EUROPISCHE NORM September 2005 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches K
9、omitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2005 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 50412-2-1:2005 E ICS 33.120.20; 97.120 English version Power line communication ap
10、paratus and systems used in low-voltage installations in the frequency range 1,6 MHz to 30 MHz Part 2-1: Residential, commercial and industrial environment Immunity requirements Equipements et systmes de communication par courants porteurs utiliss dans les installations basse tension dans la gamme d
11、e frquences de 1,6 MHz 20 MHz Partie 2-1: Environnement rsidentiel, commercial et de lindustrie lgre Exigences dimmunit Kommunikationsgerte und -systeme auf elektrischen Niederspannungsnetzen im Frequenzbereich 1,6 MHz bis 30 MHz Teil 2-1: Fr den Gebrauch in Wohnbereichen, Geschfts- und Gewerbeberei
12、chen sowie in Kleinbetrieben und in industriellen Rumlichkeiten Strfestigkeitsanforderungen This European Standard was approved by CENELEC on 2005-04-12. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the
13、 status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, Ger
14、man). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Cyprus,
15、 Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom. EN 50412-2-1:2005 2 Contents Page Foreword .3 1 Scope
16、 .4 2 Normative references.4 3 Definitions and abbreviations .5 3.1 Definitions 5 3.2 Abbreviations .6 4 Objective 7 5 Description of locations 7 6 Conditions during testing7 7 Performance criteria.8 8 Narrow band responses retail outlets, e.g. shops and supermarkets; business premises, e.g. offices
17、 and banks; areas of public entertainment e.g. cinemas, public bars and dance halls; outdoors locations e.g. petrol locations, car parks, amusements and sports centres; light-industrial locations e.g. workshops, laboratories and service centres. Class 2 locations are characterised by the existence o
18、f one or more of the following conditions: a power network exists powered by a high or medium voltage power transformer dedicated for the supply of an installation feeding manufacturing or similar plant; industrial, scientific and medical (ISM) apparatus are present; heavy inductive or capacitive lo
19、ads are frequently switched; currents and associated magnetic fields are high. 6 Conditions during testing A minimum test configuration consists of two pieces of powerline communications equipment interconnected with manufacturer specified physical cable. Associated equipment necessary to the functi
20、on of the powerline network shall be included in the test configuration. The system shall be capable of transmitting and receiving data at the nominal transmission rate specified by the manufacturer. The powerline equipment shall execute a programme that exercises all the functions available to the
21、end user. As a minimum the functions described in Clause 7 of this standard Performance criteria shall be tested. EN 50412-2-1:2005 8 7 Performance criteria Performance criterion A During and after the test, the EUT shall operate without protocol failure, loss of link, any other loss of functions re
22、levant to the user, reduction in performance below that declared by the manufacturer. The manufacturer shall choose the most appropriate performance measurement criteria for their apparatus or system e.g. bit error rate, block error rate, throughput, re-transmissions etc. Performance criterion B Deg
23、radation of the performance beyond that as described in criterion A is permitted during the application of the test provided that the normal operation of the EUT is self-recoverable to the condition immediately before the application of the test. Performance criterion C Degradation of the performanc
24、e beyond that as described in criterion A is permitted during the application of the test provided that the normal operation of the EUT is self recoverable to the condition immediately before the application of the test or can be restored after the test by the operator. 8 Narrow band responses & rad
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN50412212005POWERLINECOMMUNICATIONAPPARATUSANDSYSTEMSUSEDINLOWVOLTAGEINSTALLATIONSINTHEFREQUENCYRANGE16MHZTO30MHZRESIDENTIALCOMMERCIALANDINDUSTRIPDF

链接地址:http://www.mydoc123.com/p-574928.html