BS EN 50382-1-2008 Railway applications — nRailway rolling stock nhigh temperature npower cables having nspecial fire nperformance — nPart 1 General requirements《轨道交通 具有特殊防火性能的铁路车辆.pdf
《BS EN 50382-1-2008 Railway applications — nRailway rolling stock nhigh temperature npower cables having nspecial fire nperformance — nPart 1 General requirements《轨道交通 具有特殊防火性能的铁路车辆.pdf》由会员分享,可在线阅读,更多相关《BS EN 50382-1-2008 Railway applications — nRailway rolling stock nhigh temperature npower cables having nspecial fire nperformance — nPart 1 General requirements《轨道交通 具有特殊防火性能的铁路车辆.pdf(28页珍藏版)》请在麦多课文档分享上搜索。
1、Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 07/08/2008 08:04, Uncontrolled Copy, (c) BSIg49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58p
2、ower cables having special fire performance Part 1: General requirementsICS 13.220.40; 29.060.20; 45.060.01Railway applications Railway rolling stock high temperature BRITISH STANDARDBS EN 50382-1:2008BS EN 50382-1:2008Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 07/08/2008 08:04, Uncontro
3、lled Copy, (c) BSIThis British Standard was published under the authority of the Standards Policy and Strategy Committee on 30 May 2008 BSI 2008ISBN 978 0 580 63042 2Amendments/corrigenda issued since publicationDate CommentsCompliance with a British Standard cannot confer immunity from legal obliga
4、tions.National forewordThis British Standard is the UK implementation of EN 50382-1:2008. The UK participation in its preparation was entrusted by Technical Committee GEL/20, Electric cables, to Subcommittee GEL/20/12, Railway cables.A list of organizations represented on this committee can be obtai
5、ned on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.EUROPEAN STANDARD EN 50382-1 NORME EUROPENNE EUROPISCHE NORM March 2008 CENELEC European Committee for Electrotechnical Standardi
6、zation Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B - 1050 Brussels 2008 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 50382-1:2008 E
7、 ICS 13.220.40; 29.060.20; 45.060.01 English version Railway applications - Railway rolling stock high temperature power cables having special fire performance - Part 1: General requirements Applications ferroviaires - Cbles pour matriel roulant ferroviaire ayant des performances particulires de com
8、portement au feu - Partie 1: Prescriptions gnrales Bahnanwendungen - Hochtemperaturkabel und -leitungen fr Schienenfahrzeuge mit verbessertem Verhalten im Brandfall - Teil 1: Allgemeine Anforderungen This European Standard was approved by CENELEC on 2008-02-01. CENELEC members are bound to comply wi
9、th the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretar
10、iat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the
11、official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Port
12、ugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 07/08/2008 08:04, Uncontrolled Copy, (c) BSIEN 50382-1:2008 2 Foreword This European Standard was prepared for the Technical Committee CENELEC TC 20, Electric
13、cables, by Working Group 12, Railway Cables, as part of the overall programme of work in the Technical Committee CENELEC TC 9X, Electrical and electronic applications for railways. The text of the draft was submitted to the formal vote and was approved by CENELEC as EN 50382-1 on 2008-02-01. The fol
14、lowing dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2009-02-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2011-02-01 BS EN 50382-1:200
15、8Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 07/08/2008 08:04, Uncontrolled Copy, (c) BSI 3 EN 50382-1:2008 Contents Introduction . 4 1 Scope . 5 2 Normative references 5 3 Definitions . 6 4 Rated voltage 7 5 Marking 8 5.1 Indication of origin 8 5.2 Continuity of marks 8 5.3 Durability 8
16、5.4 Legibility 9 5.5 Additional marking 9 5.6 Use of the name CENELEC 9 6 General requirements for the construction of cables 9 6.1 Conductors 9 6.2 Insulation system . 10 6.3 Tapes 10 6.4 Sheath . 11 6.5 Overall diameter . 11 6.6 Non-metallic components . 11 7 Electrical performance 12 8 Reaction t
17、o fire Cables . 12 8.1 Flame propagation (flame spread) Single vertical cable . 12 8.2 Flame propagation (flame spread) Bunched cables 12 8.3 Smoke emission . 12 9 Reaction to fire Components . 12 9.1 Assessment of halogens 12 9.2 Toxicity 12 Annex A (normative) Requirements for halogens . 19 Annex
18、B (normative) Determination of halogens Elemental test . 21 Annex C (normative) Thickness and overall diameter Selection of samples and calculation of results . 23 Annex D (informative) Guidance on selection of cables for type approval . 24 Bibliography 25 Figures Figure 1 Example of marking . 8 Tab
19、les Table 1 Rated voltages 8 Table 2 Requirements for the tests for halogen free insulating compounds for Part 2 . 13 Table 3 Requirements for the tests for halogen free sheathing compounds for Part 2 . 16 Table A.1 Type test 19 Table A.2 Sample test . 19 Table D.1 Selection of cables for type appro
20、val 24 BS EN 50382-1:2008Licensed Copy: Wang Bin, ISO/EXCHANGE CHINA STANDARDS, 07/08/2008 08:04, Uncontrolled Copy, (c) BSIEN 50382-1:2008 4 Introduction The railway industry is generally concerned with the movement of people as well as goods. It is therefore essential that a high level of safety i
21、s achieved, even when failures occur which may involve fire, howsoever caused, affecting railway rolling stock. Hence it is necessary to provide cables for use in railway environments which minimise the hazard to people when a fire may damage the cable, irrespective of whether the fire is caused by
22、an external source or from within the electrical system. EN 50382 specifies cables for power and associated circuits which, in the event of fire, will limit the risk to people and improve the safety on railways in general. It covers cables, for use in railway rolling stock, and having standard wall
23、thickness of insulation, based on materials that allow them to operate at high temperature and which are also halogen free. In the event of a fire affecting cables to EN 50382 they will have a limited flame spread and limited emission of toxic gases. In addition these cables when burnt produce limit
24、ed amounts of smoke. This last characteristic will minimise loss of visibility in the event of a fire and will aid reduced evacuation times. The objects of this standard are to standardise cables that are safe and reliable when properly used, to state the characteristics, performance, and constructi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN5038212008RAILWAYAPPLICATIONSNRAILWAYROLLINGSTOCKNHIGHTEMPERATURENPOWERCABLESHAVINGNSPECIALFIRENPERFORMANCENPART1GENERALREQUIREMENTS

链接地址:http://www.mydoc123.com/p-574893.html