BS EN 50216-9-2009 Power transformer and reactor fittings - Oil-to-water heat exchangers《电力变压器和电抗器配件 油水热交换器》.pdf
《BS EN 50216-9-2009 Power transformer and reactor fittings - Oil-to-water heat exchangers《电力变压器和电抗器配件 油水热交换器》.pdf》由会员分享,可在线阅读,更多相关《BS EN 50216-9-2009 Power transformer and reactor fittings - Oil-to-water heat exchangers《电力变压器和电抗器配件 油水热交换器》.pdf(28页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI British StandardsWB9423_BSI_StandardColCov_noK_AW:BSI FRONT COVERS 5/9/08 12:55 Page 1Power transformer and reactor fittings Part 9: Oil-to-water heat exchangersBS EN 50216-9:2009National forewordThi
2、s British Standard is the UK implementation of EN 50216-9:2009.The UK participation in its preparation was entrusted to Technical CommitteePEL/14, Power transformers.A list of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to
3、include all the necessary provisions of acontract. Users are responsible for its correct application. BSI 2009ISBN 978 0 580 54738 6ICS 27.060.30; 29.180Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of the Stan
4、dardsPolicy and Strategy Committee on 31 October 2009Amendments issued since publicationAmd. No. Date Text affectedBRITISH STANDARDBS EN 50216-9:2009EUROPEAN STANDARD EN 50216-9 NORME EUROPENNE EUROPISCHE NORM March 2009 CENELEC European Committee for Electrotechnical Standardization Comit Europen d
5、e Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: avenue Marnix 17, B - 1000 Brussels 2009 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members. Ref. No. EN 50216-9:2009 E ICS 29.180 English vers
6、ion Power transformer and reactor fittings - Part 9: Oil-to-water heat exchangers Accessoires pour transformateurs de puissance et bobines dinductance - Partie 9: Echangeurs thermiques huile-eauZubehr fr Transformatoren und Drosselspulen - Teil 9: l-Wasser-Khler This European Standard was approved b
7、y CENELEC on 2008-10-21. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national s
8、tandards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CENELEC member into its own language and
9、notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lith
10、uania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 50216-9:2009EN 50216-9:2009 2 Foreword This European Standard was prepared by the Technical Committee CENELEC TC 14, Power transformers. The text
11、 of the draft was submitted to the formal vote and was approved by CENELEC as EN 50216-9 on 2008-10-21. This European Standard is to be read in conjunction with EN 50216-1:2002, Power transformer and reactor fittings - Part 1: General. The following dates were fixed: latest date by which the EN has
12、to be implemented at national level by publication of an identical national standard or by endorsement (dop) 2009-11-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2011-11-01 _ BS EN 50216-9:2009 3 EN 50216-9:2009 Contents 1 Scope . 4 2 Normative re
13、ferences . 4 3 Definitions . 4 4 Requirements 5 4.1 Rated values . 5 4.2 Rated cooling capacity 6 4.3 Mechanical design 6 4.4 Corrosion protection . 7 5 Designation . 7 5.1 Designation of the heat exchangers . 7 5.2 Rating plate information 7 6 Tests . 8 6.1 Routine tests . 8 6.2 Type tests . 9 7 Pr
14、eparation for transport and storage 9 8 Mounting and service, service conditions . 9 Annex A (normative) Details to the heat exchangers 10 Annex B (normative) Rating conditions of the heat exchangers . 17 Annex C (informative) Example for calculation of capacity in service 23 Bibliography 24 Figures
15、 Figure A.1 Collection and forms of suspensory types . 11 Figure A.2 Collection and forms of horizontal types 12 Figure A.3 Collection and forms of vertical standing types 13 Figure B.1 Capacity factor depending on inlet temperatures of oil and water . 19 Figure B.2 Capacity factor depending on mass
16、 for plain tubes . 20 Figure B.3 Capacity factor depending on mass for finned tubes . 21 Tables Table A.1 Devices 14 Table A.2 Examples for material selection depending on water quality . 16 Table A.3 Average values for chemically neutral water (fresh water) 16 BS EN 50216-9:2009EN 50216-9:2009 4 1
17、Scope EN 50216-9 deals with oil-to-water heat exchangers that means a heat exchanger for the cooling of the transformer oil using a forced oil circuit and a forced water circuit. The oil-side of the oil-to-water heat exchangers is not included in the scope of the Pressure Equipment Directive 97/23/E
18、C according to Article 1, 3.12. The water-side falls into Article 3, 3 of the Pressure Equipment Directive, therefore the rating plate must not contain a CE sign according to Article 15 of the Pressure Equipment Directive. This standard establishes essential dimensions and the requirements to ensure
19、 interchangeability and adequate mounting of the oil-to-water heat exchangers. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the ref
20、erenced document (including any amendment) applies. EN 50216-1:2002 Power transformers and reactor fittings - Part 1: General EN 60296 Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear (IEC 60296) EN 60721-3-4 Classification of environmental co
21、nditions - Part 3: Classification of groups of environmental parameters and their severities - Section 4: Stationary use at non-weatherprotected locations (IEC 60721-3-4) EN 1092-1 Flanges and their joints - Circular flanges for pipes, valves, fittings and accessories , PN designated - Part 1: Steel
22、 flanges EN 1561 Founding - Grey cast irons EN 1653 Copper and copper alloys - Plate, sheet and circles for boilers, pressure vessels and hot water storage units EN 10025:1990 1)Hot rolled products of non-alloy structural steels - Technical delivery conditions EN 10027-2 Designation systems for stee
23、ls - Part 2: Numerical system EN 10088-2 Stainless steels - Part 2: Technical delivery conditions for sheet/plate and strip of corrosion resisting steels for general purposes EN 10130 Cold rolled low carbon steel flat products for cold forming - Technical delivery conditions EN 12451 Copper and copp
24、er alloys - Seamless, round tubes for heat exchangers EN 12452 Copper and copper alloys - Rolled, finned, seamless tubes for heat exchangers EN 12502-1 Protection of metallic materials against corrosion - Guidance on the assessment of corrosion likelihood in water distribution and storage systems -
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN5021692009POWERTRANSFORMERANDREACTORFITTINGSOILTOWATERHEATEXCHANGERS 电力变压器 电抗 配件 油水 热交换器 PDF

链接地址:http://www.mydoc123.com/p-574667.html