BS EN 16276-2013 Evacuation Lighting in Road Tunnels《公路隧道中的疏散照明》.pdf
《BS EN 16276-2013 Evacuation Lighting in Road Tunnels《公路隧道中的疏散照明》.pdf》由会员分享,可在线阅读,更多相关《BS EN 16276-2013 Evacuation Lighting in Road Tunnels《公路隧道中的疏散照明》.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS EN 16276:2013Evacuation Lighting in RoadTunnelsBS EN 16276:2013 BRITISH STANDARDNational forewordThis British Standard is the UK implementation of EN 16276:2013.The UK partici
2、pation in its preparation was entrusted to TechnicalCommittee EL/1/2, Road lighting.A list of organizations represented on this committee can beobtained on request to its secretary.This publication does not purport to include all the necessaryprovisions of a contract. Users are responsible for its c
3、orrectapplication. The British Standards Institution 2013. Published by BSI StandardsLimited 2013ISBN 978 0 580 74896 7ICS 93.080.40Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strat
4、egy Committee on 31 January 2013.Amendments issued since publicationDate Text affectedBS EN 16276:2013EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 16276 January 2013 ICS 93.080.40 English Version Evacuation Lighting in Road Tunnels clairage des itinraires dvacuation dans les tunnels routiers
5、 Evakuierungsbeleuchtung in Straentunneln This European Standard was approved by CEN on 1 December 2012. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration
6、. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language made by t
7、ranslation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Fi
8、nland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZA
9、TION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: Avenue Marnix 17, B-1000 Brussels 2013 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 16276:2013: EBS EN 16276:2013EN 16276:2013 (E) 2 Contents
10、Page Foreword . 3 Introduction 4 1 Scope 5 2 Normative references . 5 3 Terms and definitions 5 3.1 Tunnel construction aspects . 5 3.2 Road tunnel evacuation lighting terms . 7 4 Lighting of specific areas under emergency circumstances . 8 4.1 General . 8 4.2 Driving task lighting . 8 4.2.1 Carriag
11、eway 8 4.2.2 Vehicular cross connections . 9 4.3 Pedestrian guidance 9 4.3.1 General . 9 4.3.2 Evacuation route within the main tunnel 9 4.3.3 Emergency exits . 10 4.3.4 Evacuation route outside the main tunnel 11 Annex A (informative) Adeviations . 13 Bibliography 14 BS EN 16276:2013EN 16276:2013 (
12、E) 3 Foreword This document (EN 16276:2013) has been prepared by Technical Committee CEN/TC 169 “Light and lighting”, the secretariat of which is held by DIN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the
13、 latest by July 2013, and conflicting national standards shall be withdrawn at the latest by July 2013. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all su
14、ch patent rights. According to the CEN/CENELEC Internal Regulations, the national standards organisations of the following countries are bound to implement this European Standard: Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Mace
15、donia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland, Turkey and the United Kingdom. BS EN 16276:2013EN 16276:2013 (E) 4 Introduction The Directive 2004/5
16、4/EC of the European Parliament of 29 April 2004 aims at ensuring a minimum level of safety for road users in tunnels in the Trans-European Network by the prevention of critical events that may endanger human life. With regard to lighting, there are two main cases: normal lighting and safety lightin
17、g. Normal lighting is provided to ensure appropriate visibility during the day and night for drivers in the entrance zone as well as in the interior zone. Safety lighting is divided into two parts: standby lighting and evacuation lighting. Standby lighting is provided to ensure a minimum visibility
18、for tunnel users to evacuate the tunnel in their vehicles in the event of a breakdown of the power supply. Evacuation lighting is provided to guide tunnel users during evacuation of the tunnel on foot in emergency circumstances such as fire. Evacuation lighting includes evacuation route marker light
19、s, emergency exit lighting, emergency exit marker lights and evacuation route lighting. BS EN 16276:2013EN 16276:2013 (E) 5 1 Scope This European Standard specifies evacuation lighting in road tunnels longer than 500 m and with an AADT (Annual Average Daily Traffic) higher than 500 vehicles to facil
20、itate the safe evacuation of vehicle occupants in evacuation situations such as fire. It addresses the fundamental issues of evacuation lighting for evacuation routes, emergency exits and cross connections, as well as giving some practical advice regarding aspects of installation and maintenance in
21、road tunnels. It is intended to be used in conjunction with CEN/CR 14380:2003 or relevant national standards for road tunnel lighting. The recommendations may be applied to tunnels up to 500 m in length, especially where conditions such as high traffic volume, or severe curvature or gradient apply.
22、It specifies lighting levels and general provisions for evacuation lighting installations that, based on experience, are considered to be necessary for the safety of people driving through road tunnels in case of an incident and particularly in case of fire. However, as there are different types of
23、road tunnels, both in construction and traffic conditions, various types of incident may occur. This standard should be considered as a list of minimum prescriptions for evacuation lighting in tunnels, to be completed by means of specific risk analysis for the particular tunnel. The design of markin
24、g and safety signs is not part of this standard. 2 Normative references The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest editio
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN162762013EVACUATIONLIGHTINGINROADTUNNELS 公路 隧道 中的 疏散 照明 PDF

链接地址:http://www.mydoc123.com/p-573760.html