BS EN 3661-006-2006 Aerospace series - Circuit breakers single-pole temperature compensated rated current 20 A to 50 A - Part 006 With polarized signal contact - Bus bar version - .pdf
《BS EN 3661-006-2006 Aerospace series - Circuit breakers single-pole temperature compensated rated current 20 A to 50 A - Part 006 With polarized signal contact - Bus bar version - .pdf》由会员分享,可在线阅读,更多相关《BS EN 3661-006-2006 Aerospace series - Circuit breakers single-pole temperature compensated rated current 20 A to 50 A - Part 006 With polarized signal contact - Bus bar version - .pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARDBS EN 3661-006:2006Aerospace series Circuit breakers, single-pole, temperature compensated, rated current 20 A to 50 A Part 006: With polarized signal contact Bus bar version Product standardThe European Standard EN 3661-006:2006 has the status of a British StandardICS 49.060g49g50g3
2、g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58Licensed Copy: Wang Bin, na, Thu Apr 05 07:27:08 GMT+00:00 2007, Uncontrolled Copy, (c) BSIBS EN 3661-006:20
3、06This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 January 2007 BSI 2007ISBN 978 0 580 50008 4National forewordThis British Standard was published by BSI. It is the UK implementation of EN 3661-006:2006.The UK participation in its preparati
4、on was entrusted by Technical Committee ACE/6, Aerospace avionic electrical and fibre optic technology, to Panel ACE/6/-/5, Aerospace Protection for electrical systems.A list of organizations represented on ACE/6/-/5 can be obtained on request to its secretary.This publication does not purport to in
5、clude all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.Amendments issued since publicationAmd. No. Date CommentsLicensed Copy: Wang Bin, na, Thu Apr 05 07:27:08 GMT+00:00 200
6、7, Uncontrolled Copy, (c) BSIEUROPEAN STANDARDNORME EUROPENNEEUROPISCHE NORMEN 3661-006August 2006ICS 49.060English VersionAerospace series - Circuit breakers, single-pole, temperaturecompensated, rated current 20 A to 50 A - Part 006: Withpolarized signal contact - Bus bar version - Product standar
7、dSrie arospatiale - Disjoncteurs unipolaires compenss entemprature, intensits nominales 20 A 50 A - Partie 006: Avec contact de signalisation polaris - Version pourbarres bus - Norme de produitLuft- und Raumfahrt - Schutzschalter, einpolig,Temperaturkompensiert, Nennstrme von 20 A bis 50 A -Teil 006
8、: Mit polarisiertem Signalkontakt -Sammelschienenversion - ProduktnormThis European Standard was approved by CEN on 5 June 2006.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this EuropeanStandard the status of a national standard
9、without any alteration. Up-to-date lists and bibliographical references concerning such nationalstandards may be obtained on application to the Central Secretariat or to any CEN member.This European Standard exists in three official versions (English, French, German). A version in any other language
10、 made by translationunder the responsibility of a CEN member into its own language and notified to the Central Secretariat has the same status as the officialversions.CEN members are the national standards bodies of Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France,Germany,
11、 Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania,Slovakia, Slovenia, Spain, Sweden, Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATIONCOMIT EUROPEN DE NORMALISATIONEUROPISCHES KOMITEE FR NORMUNGManageme
12、nt Centre: rue de Stassart, 36 B-1050 Brussels 2006 CEN All rights of exploitation in any form and by any means reservedworldwide for CEN national Members.Ref. No. EN 3661-006:2006: ELicensed Copy: Wang Bin, na, Thu Apr 05 07:27:08 GMT+00:00 2007, Uncontrolled Copy, (c) BSI2 Contents Page Foreword3
13、1 Scope 4 2 Normative references 4 3 Dimensions and mass.4 4 Characteristics.6 5 Designation 10 6 Rated current code 11 7 Delivery codes11 8 Marking .11 9 Technical specification .11 EN 3661-006:2006Licensed Copy: Wang Bin, na, Thu Apr 05 07:27:08 GMT+00:00 2007, Uncontrolled Copy, (c) BSI3 Foreword
14、 This European Standard (EN 3661-006:2006) has been prepared by the Aerospace and Defence Industries Association of Europe - Standardization (ASD-STAN). After enquiries and votes carried out in accordance with the rules of this Association, this Standard has received the approval of the National Ass
15、ociations and the Official Services of the member countries of ASD, prior to its presentation to CEN. This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by February 2007, and conflicting national standa
16、rds shall be withdrawn at the latest by February 2007. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. According to the CEN/CENELEC In
17、ternal Regulations, the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Cyprus, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Net
18、herlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. EN 3661-006:2006Licensed Copy: Wang Bin, na, Thu Apr 05 07:27:08 GMT+00:00 2007, Uncontrolled Copy, (c) BSI4 1 Scope This standard specifies the characteristics of single-pole circuit
19、breakers, temperature compensated with a rated current from 20 A to 50 A, used in aircraft on-board circuits at a temperature between 55 C and 125 C and at an altitude of 15 000 m max. These circuit breakers are operated by a push-pull type single push button (actuator), with delayed action “trip-fr
20、ee“ tripping with a polarized signal contact which is open when main contacts are closed, and inversely. They are connected on supply side by means of bus-bar. They will continue to function up to the short-circuit current. 2 Normative references The following referenced documents are indispensable
21、for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. EN 3155-016, Aerospace series Electrical contacts used in elements of connection Part 016: Contacts, e
22、lectrical, male, type A, crimp, class S Product standard. EN 3661-001, Aerospace series Circuit breakers, single-pole, temperature compensated, rated current 20 A to 50 A Part 001: Technical specification. EN 3841-305, Aerospace series Circuit breakers Test methods Part 305: Short-circuit performanc
23、e. EN 6113, Aerospace series Circuit breaker, connecting and attachment hardware.1)TR 6083, Aerospace series Cut-outs for installation of electrical components.2)MIL-I-81969/1A, Installing and removal tools, connector electrical contact, type III, class 2, composition C.3)MIL-I-81969/14C, Installing
24、 and removal tools, connector electrical contact, type III, class 2, composition B.3)MIL-S-19500, Semiconductor device, diode, silicon, fast recovery.3)FED-STD-595B, Colors used in Government Procurement. 3 Dimensions and mass 3.1 Dimensional characteristics The circuit breakers do not have to corre
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN36610062006AEROSPACESERIESCIRCUITBREAKERSSINGLEPOLETEMPERATURECOMPENSATEDRATEDCURRENT20ATO50APART006WITHPOLARIZEDSIGNALCONTACTBUSBARVERSIONPDF

链接地址:http://www.mydoc123.com/p-550913.html