BS EN 1397-2015 Heat exchangers Hydronic room fan coil units Test procedures for establishing the performance《热交换器 水循环加热间的电扇线圈装置 性能确定的试验程序》.pdf
《BS EN 1397-2015 Heat exchangers Hydronic room fan coil units Test procedures for establishing the performance《热交换器 水循环加热间的电扇线圈装置 性能确定的试验程序》.pdf》由会员分享,可在线阅读,更多相关《BS EN 1397-2015 Heat exchangers Hydronic room fan coil units Test procedures for establishing the performance《热交换器 水循环加热间的电扇线圈装置 性能确定的试验程序》.pdf(30页珍藏版)》请在麦多课文档分享上搜索。
1、BS EN 1397:2015Heat exchangers Hydronicroom fan coil units Testprocedures for establishing theperformanceIncorporating corrigendum June 2016BSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06BS EN 1397:2015 BRITISH STANDARDNational forewordThis British Standard is the U
2、K implementation of EN 1397:2015,The UK participation in its preparation was entrusted to TechnicalCommittee RHE/17, Testing of air conditioning units.A list of organizations represented on this committee can beobtained on request to its secretary.This publication does not purport to include all the
3、 necessaryprovisions of a contract. Users are responsible for its correctapplication.ISBN 978 0 580 95092 6ICS 27.060.30Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committe
4、e on 31 August 2015.Amendments/corrigenda issued since publicationDate Text affected31 July 2016 Implementation of CEN corrigendum June 2016:Subclause 7.5.3, Formula (4) modified The British Standards Institution 2016.Published by BSI Standards Limited 2016BS EN 1397:1999 which is withdrawn.incorpor
5、ating corrigendum June 2016. It supersedes EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 1397 ICS 27.060.30 Supersedes EN 1397:1998English Version Heat exchangers - Hydronic room fan coil units - Test procedures for establishing the performance changeurs thermiques - Ventilo-convecteurs eau -
6、 Procdures dessai pour la dtermination des performancesWrmebertrager - Wasser-Luft-Ventilatorkonvektoren - Prfverfahren zur Leistungsfeststellung This European Standard was approved by CEN on 3 July 2015. CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the c
7、onditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CEN member. This European Standard ex
8、ists in three official versions (English, French, German). A version in any other language made by translation under the responsibility of a CEN member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CEN members are the national s
9、tandards bodies of Austria, Belgium, Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland, Former Yugoslav Republic of Macedonia, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, Netherlands, Norway, Poland, Portugal, Romania, Slovakia,
10、 Slovenia, Spain, Sweden, Switzerland, Turkey and United Kingdom. EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG CEN-CENELEC Management Centre: Avenue Marnix 17, B-1000 Brussels 2015 CEN All rights of exploitation in any form and by any means res
11、erved worldwide for CEN national Members. Ref. No. EN 1397:2015 EIncorporating corrigendum June 2016BS EN 1397:2015EN 1397:2015 (E) 2 Contents Page European foreword .3 1 Scope 4 2 Normative references 4 3 Terms and definitions .4 4 Designation of fan coil units .6 5 Symbols 6 6 Air flow rate test f
12、or ducted units 7 6.1 General conditions 7 6.2 Test installation 7 6.3 Pressure settings .8 6.4 Standard rating conditions .9 6.5 Test procedure .9 6.6 Data to be recorded 10 7 Capacity rating tests 10 7.1 General conditions . 10 7.2 Test room . 10 7.3 Installation of the test object . 11 7.4 Standa
13、rd rating conditions 11 7.5 Test method . 12 7.6 Measurements criteria 13 7.7 Uncertainties of measurement from indicated values 15 7.8 Test duration . 15 7.9 Data to be recorded 16 8 Performance tests. 17 8.1 General . 17 8.2 Test conditions . 17 8.3 Sweat test 17 8.4 Condensate disposal test 17 9
14、Test report . 18 9.1 General information 18 9.2 Additional information . 18 9.3 Test results 18 10 Manufacturers data 19 Annex A (informative) Drawings of the different types of configurations of fan coil units 20 Annex B (informative) Air flow rate test for non-ducted units . 23 Annex C (normative)
15、 Design of separation partition for testing of cassette type fan coil units . 25 BS EN 1397:2015EN 1397:2015 (E) 3 European foreword This document (EN 1397:2015) has been prepared by Technical Committee CEN/TC 113 “Heat pumps and air conditioning units”, the secretariat of which is held by AENOR. Th
16、is European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by February 2016 and conflicting national standards shall be withdrawn at the latest by February 2016. Attention is drawn to the possibility that some of
17、 the elements of this document may be the subject of patent rights. CEN and/or CENELEC shall not be held responsible for identifying any or all such patent rights. This document supersedes EN 1397:1998. The main modifications with regard to the previous edition include: modification of the scope, wi
18、th the inclusion of ducted units 20 kPa) Air dry bulb temperature C 0,2 K dew point temperature C 0,3 K static pressure difference Pa 3 Pa (p 100 Pa) 3 % (p 100 Pa) Others brine concentration % 2 % atmospheric pressure kPa 0.5 kPa fan speed min-1 1 % mass kg 0.5 % Electrical quantities electric powe
19、r W 1 % or at least 1 W voltage V 0,5 % current A 0,5 % electrical energy Wh 1 % The heating, the total cooling and latent capacities obtained from measurements on the liquid side shall be determined with a maximum uncertainty of measurement of 5 % independent of the individual uncertainties of meas
20、urement including uncertainties of the properties of fluids. 7.8 Test duration It is necessary to record all the meaningful data continuously. In case of recording instruments which operate on a cyclic basis, the sequence shall be adjusted such that a complete recording is effectuated at least once
21、every 30 s. The data shall be measured in steady state operation. The duration of the measurement shall not be less than 30 min. BS EN 1397:2015EN 1397:2015 (E) 16 7.9 Data to be recorded The data to be recorded for the air flow and capacity tests are given in Table 9. The table identifies the gener
22、al information required but is not intended to limit the data to be obtained. These data shall be the mean values taken over the data recording period. Table 9 Data to be recorded Symbol Unit Atmospheric pressure PatmkPa Voltage - V Frequency - Hz Speed control setting of the fan speed - - Rotationa
23、l speed of the fan n2min-1 Total electric power input PelecW Air inlet dry bulb temperature tAC Air inlet wet bulb temperature tAwC Air inlet dew point temperature tAdpC External static pressure, where applicable pAPa Mass flow rate of condensate (air side) qmWq/s Inlet liquid temperature tL1C Outle
24、t liquid temperature tL2C Liquid mass flow rate qmLg/s Brine concentration, where applicable - % vol Specific heat capacity of liquid at tL1cpL1kJ/(kg.K) Specific heat capacity of liquid at tL2cpL2kJ/(kg.K) Specific enthalpy of liquid at at tL1hL1kJ/kg Specific enthalpy of liquid at tL2hL2kJ/kg Liqu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN13972015HEATEXCHANGERSHYDRONICROOMFANCOILUNITSTESTPROCEDURESFORESTABLISHINGTHEPERFORMANCE 热交换器 水循环

链接地址:http://www.mydoc123.com/p-548972.html