BS DD IEC TS 62351-6-2007 Power systems management and associated information exchange - Data and communication security - Security for IEC 61850 profiles《动力系统管理和相关的信息交换 数据和通信安全 IE.pdf
《BS DD IEC TS 62351-6-2007 Power systems management and associated information exchange - Data and communication security - Security for IEC 61850 profiles《动力系统管理和相关的信息交换 数据和通信安全 IE.pdf》由会员分享,可在线阅读,更多相关《BS DD IEC TS 62351-6-2007 Power systems management and associated information exchange - Data and communication security - Security for IEC 61850 profiles《动力系统管理和相关的信息交换 数据和通信安全 IE.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、 g49g50g3g38g50g51g60g44g49g42g3g58g44g55g43g50g56g55g3g37g54g44g3g51g40g53g48g44g54g54g44g50g49g3g40g59g38g40g51g55g3g36g54g3g51g40g53g48g44g55g55g40g39g3g37g60g3g38g50g51g60g53g44g42g43g55g3g47g36g58exchange Data and communications security Part 6: Security for IEC 61850 ICS 33.200Power systems ma
2、nagement and associated information DRAFT FOR DEVELOPMENTDD IEC/TS 62351-6:2007DD IEC/TS 62351-6:2007This Draft for Development was published under the authority of the Standards Policy and Strategy Committee on 31 July 2007 BSI 2007ISBN 978 0 580 56448 2to withdraw it. Comments should be sent to th
3、e Secretary of the responsible BSI Technical Committee at British Standards House, 389 Chiswick High Road, London W4 4AL.The UK participation in its preparation was entrusted to Technical Committee PEL/57, Power systems management and associated information exchange.A list of organizations represent
4、ed on this committee can be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Amendments issued since publicationAmd. No. Date Commentsresponsible for its conversion to an in
5、ternational standard. A review of this publication will be initiated not later than 3 years after its publication by the international organization so that a decision can be taken on its status. Notification of the start of the review period will be made in an announcement in the appropriate issue o
6、f Update Standards.According to the replies received by the end of the review period, the responsible BSI Committee will decide whether to support the conversion into an international Standard, to extend the life of the Technical Specification or National forewordThis Draft for Development is the UK
7、 implementation of IEC/TS 62351-6:2007.This publication is not to be regarded as a British Standard.It is being issued in the Draft for Development series of publications and is of a provisional nature. It should be applied on this provisional basis, so that information and experience of its practic
8、al application can be obtained.Comments arising from the use of this Draft for Development are requested so that UK experience can be reported to the international organization TECHNICAL SPECIFICATION IECTS 62351-6First edition2007-06Power systems management and associated information exchange Data
9、and communications security Part 6: Security for IEC 61850 Reference number IEC/TS 62351-6:2007(E) DD IEC/TS 62351-6:2007CONTENTS 1 Scope and object3 1.1 Scope3 1.2 Object .3 2 Normative references .3 3 Definitions 4 4 Security issues addressed by this specification 4 4.1 Operational issues affectin
10、g choice of security options4 4.2 Security threats countered.5 4.3 Attack methods countered .5 5 Correlation of IEC 61850 parts and IEC 62351 parts 5 5.1 IEC 61850 security for profiles using ISO 9506 (MMS) 5 5.1.1 General .5 5.1.2 Control centre to substation.5 5.1.3 Substation communications .5 5.
11、2 IEC 61850 security for profiles using VLAN IDs .6 6 IEC 61850 security for SNTP6 7 IEC 61850 security for profiles using VLAN technologies6 7.1 Overview of VLAN usage and IEC 61850 (informative) 6 7.2 Extended PDU.6 7.2.1 General format of extended PDU .6 7.2.2 Format of extension octets 7 7.2.3 S
12、ubstation configuration language.10 8 Conformance11 8.1 General conformance 11 8.2 Conformance for implementations claiming ISO 9506 profile security 12 8.3 Conformance for implementations claiming VLAN profile security12 8.4 Conformance for implementations claiming SNTP profile security13 Bibliogra
13、phy14 Figure 1 General format of extended PDU6 Figure 2 SCL extensions for certificates.10 Figure 3 Extension to AccessPoint SCL definition 11 Table 1 Scope of application to standards3 Table 2 Extract from IEC 61850-9-2 (informative) 9 Table 3 Conformance table 12 Table 4 PICS for ISO 9506 profile1
14、2 Table 5 PICS for VLAN profiles12 Table 6 PICS for SNTP profiles13 DD IEC/TS 62351-6:2007 2 POWER SYSTEMS MANAGEMENT AND ASSOCIATED INFORMATION EXCHANGE DATA AND COMMUNICATIONS SECURITY Part 6: Security for IEC 61850 1 Scope and object 1.1 Scope This part of IEC 62351 specifies messages, procedures
15、, and algorithms for securing the operation of all protocols based on or derived from the standard IEC 61850. This specification applies to at least those protocols listed in Table 1. Table 1 Scope of application to standards Number Name IEC 61850-8-1 Communication networks and systems in substation
16、s Part 8-1: Specific Communication Service Mapping (SCSM) Mappings to MMS (ISO/IEC 9506-1 and ISO/IEC 9506-2) and to ISO/IEC 8802-3 IEC 61850-9-2 Communication networks and systems in substations Part 9-2: Specific Communication Service Mapping (SCSM) Sampled values over ISO/IEC 8802-3 IEC 61850-6 C
17、ommunication networks and systems in substations Part 6: Configuration description language for communication in electrical substations related to IEDs 1.2 Object The initial audience for this specification is intended to be the members of the working groups developing or making use of the protocols
18、 listed in Table 1. For the measures described in this specification to take effect, they must be accepted and referenced by the specifications for the protocols themselves. This document is written to enable that process. The subsequent audience for this specification is intended to be the develope
19、rs of products that implement these protocols. Portions of this specification may also be of use to managers and executives in order to understand the purpose and requirements of the work. 2 Normative references The following referenced documents are indispensable for the application of this documen
20、t. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. IEC 61850 (all parts), Communication networks and systems in substations IEC 61850-6, Communication networks and systems in substations P
21、art 6: Configuration description language for communication in electrical substations related to IEDs IEC 61850-8-1, Communication networks and systems in substations Part 8-1: Specific Communication Service Mapping (SCSM) Mappings to MMS (ISO 9506-1 and ISO 9506-2) and to ISO/IEC 8802-3 DD IEC/TS 6
22、2351-6:2007 3 IEC 61850-9-1, Communication networks and systems in substations Part 9-1: Specific Communication Service Mapping (SCSM) Sampled values over serial unidirectional multidrop point to point link IEC 61850-9-2, Communication networks and systems in substations Part 9-2: Specific Communica
23、tion Service Mapping (SCSM) Sampled values over ISO/IEC 8802-3 IEC 62351-1, Power systems management and associated information exchange Data and communications security Part 1: Communication network and system security Introduction to security issues IEC 62351-2, Power systems management and associ
24、ated information exchange Data and communications security Part 2: Glossary of terms IEC 62351-4, Power systems management and associated information exchange Data and communications security Part 4: Profiles including MMS ISO 9506 (all parts), Industrial automation systems Manufacturing Message Spe
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSDDIECTS6235162007POWERSYSTEMSMANAGEMENTANDASSOCIATEDINFORMATIONEXCHANGEDATAANDCOMMUNICATIONSECURITYSECURITYFORIEC61850PROFILES

链接地址:http://www.mydoc123.com/p-548345.html