BS 7967-2015 Guide for the use of electronic portable combustion gas analysers for the measurement of carbon monoxide in dwellings and the combustion performance of domestic gas-fi.pdf
《BS 7967-2015 Guide for the use of electronic portable combustion gas analysers for the measurement of carbon monoxide in dwellings and the combustion performance of domestic gas-fi.pdf》由会员分享,可在线阅读,更多相关《BS 7967-2015 Guide for the use of electronic portable combustion gas analysers for the measurement of carbon monoxide in dwellings and the combustion performance of domestic gas-fi.pdf(62页珍藏版)》请在麦多课文档分享上搜索。
1、BSI Standards PublicationGuide for the use of electronic portable combustion gas analysers for the measurement of carbon monoxide in dwellings and the combustion performance of domestic gasfired appliancesBS 7967:2015BS 7967:2015 BRITISH STANDARDPublishing and copyright informationThe BSI copyright
2、notice displayed in this document indicates when the document was last issued. The British Standards Institution 2015 Published by BSI Standards Limited 2015ISBN 978 0 580 77879 7ICS 13.040.40; 97.100.20The following BSI references relate to the work on this document: Committee reference GSE/30 Draf
3、t for comment 14/30258585 DCPublication historyFirst published as BS 7967-1, BS 7967-2 and BS 7967-3, December 2005 BS 7967-4, June 2007First published as BS 7967, February 2015Amendments issued since publicationDate Text affected The British Standards Institution 2015 iBS 7967:2015BRITISH STANDARDC
4、ontentsForeword iv1 Scope 12 Normative references 33 Terms and definitions 34 Competence 55 Gas analyser 75.1 Selection 75.2 Preparation of gas analyser 75.2.1 Pre-checks before use 75.2.2 Preparation of gas analyser for use 76 Investigation of reports of fumes, smells and spillage/leakage of combus
5、tion products in dwellings 86.1 Determining scope of investigation 86.2 Safety principles 86.2.1 Basic rules 86.2.2 CO investigation action levels 96.3 Preliminary procedure for carrying out checks for CO spillage/leakage from gas appliances 96.3.1 Possible circumstance identified by preliminary dis
6、cussion with customer (see Figure 1) 116.3.2 Sweep test for open-flue and room-sealed appliances 116.3.3 Detailed discussion with customer (see Figure 1) 116.4 Confirming safe operation of a gas appliance 126.4.1 Investigation of “suspect” gas appliances 126.4.2 Detailed examination 146.4.3 Addition
7、al checks when combustion performance is satisfactory 156.4.4 Final checks 156.5 Specific gas appliance considerations 156.5.1 General 156.5.2 Air extraction/circulation systems 156.5.3 Flueless (type A) 166.5.4 Open-flue (type B) 166.5.5 Room-sealed (type C) 166.5.6 Warm air heaters 166.5.7 Fires 1
8、76.5.8 Fire/back boilers and fire/back circulators 176.5.9 Cookers 186.5.10 Appliances in compartments 186.6 Check of non-gas appliances and/or for continued smell/presence of CO 187 Reacting to activation of CO detectors 207.1 General 207.2 Electrical CO detector 207.3 CO indicator card 228 Determi
9、ning ambient levels of carbon monoxide (CO) in a room 228.1 General advice on measurement procedures 228.2 Preparation for CO build-up testing 238.3 Testing procedures 238.3.1 General 238.3.2 Room-sealed (type C) appliances 248.3.3 Open-flue (type B) appliances 248.3.4 Flueless (type A) appliances 2
10、48.3.5 Additional considerations 258.3.6 Identifying external sources of CO 259 Information on levels of CO 269.1 General 26BS 7967:2015ii The British Standards Institution 2015BRITISH STANDARD9.2 Additional information on levels of CO for gas cookers 269.3 Responding to CO levels 269.4 CO from appl
11、iances other than gas appliances 279.5 CO from sources other than appliances 279.6 References to information on the effects of CO 289.7 Movement of CO 289.8 Generation of CO, smells and fumes when no fault with gas installation 2810 Determination of the combustion performance of an appliance 2910.1
12、Types of gas-fired appliance 2910.2 General procedures 2910.3 Sample probes 3010.4 Sampling procedure 3010.4.1 Flueless (type A) appliances 3010.4.2 Open-flue (type B) appliances 3210.4.3 Room-sealed (type C) appliances 3411 Procedure for commissioning, servicing and maintenance using a gas analyser
13、 3411.1 General 3411.2 Confirmation of safe and/or efficient operation at the time of commissioning 3511.3 Determination of the level of servicing required and subsequent actions (see Figure 5) 3511.4 Confirmation of satisfactory combustion following servicing in accordance with the gas appliance in
14、structions (Figure 6) 3711.5 Confirmation of satisfactory combustion following maintenance (Figure 7) 3812 Combustion action levels 4012.1 General 4012.2 CO/CO2ratios above the action level 4112.3 Failure to achieve a satisfactory combustion performance 4113 Completion and leaving the property 4114
15、Reports 42AnnexesAnnex A (informative) Gas analyser 43Annex B (informative) Movement of CO in buildings 43Annex C (normative) Multi-hole sample probes 45Annex D (informative) Flue/draught diverter configurations for warm air heaters 46Annex E (informative) Background to the use of a gas analyser in
16、regular servicing 47Annex F (informative) Dwelling investigation report 48Annex G (informative) Gas appliance investigation report 49Bibliography 50List of figuresFigure 1 Flow chart of the preliminary procedure for carrying out checks for CO spillage/leakage from gas appliances 10Figure 2 Flow char
17、t for confirming safe operation of a gas appliance 12Figure 3 Flow chart for non-gas appliances and/or continued smell/presence of CO 19Figure 4 Responding to electrical CO detector (alarm) activations 21Figure 5 Procedure for use of a gas analyser to determine whether or not the combustion performa
18、nce is satisfactory, and the subsequent actions to be performed 36 The British Standards Institution 2015 iiiBS 7967:2015BRITISH STANDARDFigure 6 Procedure for the use of a gas analyser as an aid to checking combustion performance subsequent to servicing carried out in accordance with the gas applia
19、nce instructions 38Figure 7 Procedure for the use of a gas analyser to confirm satisfactory combustion following maintenance 39Figure C.1 Probe for gas cooker grill 45Figure C.2 Angled probe 45Figure D.1 Flue/draught diverter configurations for warm air heaters 46Figure F.1 Example format of a dwell
20、ing investigation report 48Figure G.1 Example format of a gas appliance investigation report 49List of tablesTable 1 Approval bodies and statutory regulations by country/territory 6Table 2 Competence requirements by country/territory 6Table 3 Combustion performance (CO/CO2ratio) action levels 13Summ
21、ary of pagesThis document comprises a front cover, an inside front cover, pages i to vi, pages 1 to 52, an inside back cover and a back cover.BS 7967:2015iv The British Standards Institution 2015BRITISH STANDARDForewordPublishing informationThis British Standard is published by BSI Standards Limited
22、, under licence from The British Standards Institution, and came into effect on 28 February 2015. It was prepared by Panel GSE/30/-/21, Gas Analysers, under the authority of Technical Committee GSE/30, Gas installations (1st, 2nd and 3rd family gases). A list of organizations represented on this com
23、mittee can be obtained on request to its secretary.SupersessionThis British Standard supersedes BS 7967-1:2005, BS 7967-2:2005, BS 7967-3:2005 and BS 7967-4:2007, which are withdrawn. BS 7967-5, which covers the use of electronic portable combustion gas analysers in non-domestic premises, remains cu
24、rrent.Information about this documentThis British Standard is intended to be used in conjunction with the gas appliance commissioning, servicing and maintenance instructions and the Gas Industry Unsafe Situations Procedure 1.Its purpose is to provide:a) information that is intended to assist gas ope
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS79672015GUIDEFORTHEUSEOFELECTRONICPORTABLECOMBUSTIONGASANALYSERSFORTHEMEASUREMENTOFCARBONMONOXIDEINDWELLINGSANDTHECOMBUSTIONPERFORMANCEOFDOMESTICGASFIPDF

链接地址:http://www.mydoc123.com/p-547204.html