BS 7273-3-2008 Code of practice for the operation of fire protection measures - Part 3 Electrical actuation of pre-action watermist and sprinkler systems《防火措施的采用实施规程 第3部分 预作用水雾和喷水灭.pdf
《BS 7273-3-2008 Code of practice for the operation of fire protection measures - Part 3 Electrical actuation of pre-action watermist and sprinkler systems《防火措施的采用实施规程 第3部分 预作用水雾和喷水灭.pdf》由会员分享,可在线阅读,更多相关《BS 7273-3-2008 Code of practice for the operation of fire protection measures - Part 3 Electrical actuation of pre-action watermist and sprinkler systems《防火措施的采用实施规程 第3部分 预作用水雾和喷水灭.pdf(26页珍藏版)》请在麦多课文档分享上搜索。
1、BS 7273-3:2008Code of practice for the operation of fire protection measures Part 3: Electrical actuation of pre-action watermist and sprinkler systemsICS 13.220.20NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBRITISH STANDARDPublishing and copyright informationThe BSI copyri
2、ght notice displayed in this document indicates when the document was last issued. BSI 2008ISBN 978 0 580 58175 5The following BSI references relate to the work on this standard:Committee reference FSH/12/4Draft for comment 07/30160342 DCPublication historyFirst published October 2000Second edition,
3、 January 2008Amendments issued since publicationAmd. no. Date Text affectedBS 7273-3:2008 BSI 2008 iBS 7273-3:2008ContentsForeword iiiIntroduction 11 Scope 32 Normative references 33 Terms and definitions 44 System design 55 System interface 96 Power supplies, cables and wiring 127 Commissioning and
4、 handover 13AnnexesAnnex A (informative) Example of an arrangement for c.i.e. with separate e.c.d. 14Annex B (informative) Example of an arrangement for c.i.e. with combined e.c.d. 15Annex C (informative) Example of an arrangement for any coincidence logic provided within the c.i.e. 16Annex D (infor
5、mative) Example of an arrangement for any coincidence logic provided within the e.c.d. 17Bibliography 18List of figuresFigure 1 Typical logic gate depiction of pre-action systems 2Figure A.1 Example of an arrangement for c.i.e. with separate e.c.d. 14Figure B.1 Example of an arrangement for c.i.e. w
6、ith combined e.c.d. 15Figure C.1 Example of an arrangement for any coincidence logic provided within the c.i.e. 16Figure D.1 Example of an arrangement for any coincidence logic provided within the e.c.d. 17List of tablesTable 1 Maximum areas of coverage per point-type smoke detector to operate pre-a
7、ction watermist and sprinkler systems in still air conditions 7Summary of pagesThis document comprises a front cover, an inside front cover, pages i to iv, pages 1 to 18, an inside back cover and a back cover.BS 7273-3:2008ii BSI 2008 This page deliberately left blank BSI 2008 iiiBS 7273-3:2008Forew
8、ordPublishing informationThis part of BS 7273 is published by BSI and came into effect on 31 January 2008. It was prepared by Subcommittee FSH/12/4, Automatic operation of fire protection, under the authority of Technical Committee FSH/12, Fire detection and alarm systems. A list of organizations re
9、presented on this committee can be obtained on request to its secretary.SupersessionThis part of BS 7273 supersedes BS 7273-3:2000, which is withdrawn.Relationship with other publicationsBS 7273 is published in a series of parts:Part 1: Electrical actuation of gaseous total flooding extinguishing sy
10、stems;Part 2: Mechanical actuation of gaseous total flooding and local application extinguishing systems;Part 3: Electrical actuation of pre-action watermist and sprinkler systems;Part 4: Actuation of release mechanisms for doors;Part 5: Electrical actuation of watermist systems.Parts 1 and 2 give r
11、ecommendations for the electrical and mechanical actuation of gaseous fire extinguishing systems respectively. Part 4 gives recommendations for the actuation of release mechanisms for doors. Part 5 provides recommendations for electrical actuation of watermist systems (other than pre-action watermis
12、t systems). This current part of BS 7273 provides recommendations for the electrical actuation of pre-action watermist and sprinkler systems.Recommendations for the design, installation, commissioning and maintenance of fire detection and fire alarm systems are given in BS 5839-1. Recommendations fo
13、r the design, installation, commissioning and maintenance of sprinkler systems are given in BS EN 12845. Recommendations for the design, installation, commissioning and maintenance of watermist systems will be given in DD 8489-1, which is currently in preparation. It is anticipated that an amendment
14、 will be issued to BS 7273-3 when DD 8489-1 is published.Information about this documentThis is a full revision of BS 7273-3. The principal changes from the previous edition are as follows. The scope of the standard now includes pre-action watermist systems. References have been updated. Terminology
15、 has been brought into line with related standards, particularly in relation to control and indicating equipment. Reference is made to DD 8489-1 and BS EN 12845.BS 7273-3:2008iv BSI 2008Use of this documentAs a code of practice, this part of BS 7273 takes the form of guidance and recommendations. It
16、 should not be quoted as if it were a specification and particular care should be taken to ensure that claims of compliance are not misleading.Any user claiming compliance with this British Standard is expected to be able to justify any course of action that deviates from its recommendations.Hazard
17、warningsPresentational conventionsThe provisions in this standard are presented in roman (i.e. upright) type. Its recommendations are expressed in sentences in which the principal auxiliary verb is “should”.Commentary, explanation and general informative material is presented in smaller, italic type
18、, and does not constitute a normative element.Contractual and legal considerationsThis publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligation
19、s.CAUTION. Certain electromagnetic fields, such as those generated by radio frequency transmitters, could potentially trigger the charging of pre-action watermist and sprinkler systems or cause them to malfunction. In such cases it is appropriate to take action to minimize the risk of unintentional
20、charging of the pipework due to the electromagnetic field radiated by such apparatus. It might be necessary to seek specialist advice. BSI 2008 1BS 7273-3:2008IntroductionA pre-action sprinkler system is a fire extinguishing system which consists of a sprinkler system and an electrical detection sys
21、tem with water held back by the pre-action valve and pressurized air in the sprinkler pipework. In the event of the operation of the electrical detection system, the pre-action alarm valve operates and allows water into the sprinkler pipework. Pre-action watermist systems work on the same principle.
22、Two generic forms of operation exist: type A and type B.In the case of a type A pre-action system, water will only enter the pipework following the operation of the detection system. Accordingly, type A pre-action systems will only discharge water onto the seat of the fire when both the electrical d
23、etection system and any automatic sprinkler head or watermist nozzle has operated. Any accidental damage to the sprinklers/watermist nozzles, or pipework, will not cause water to be discharged.Type A systems are, therefore, suitable for use in situations in which: there is high potential for mechani
24、cal damage to the system; or the probability of mechanical damage might not be high, but the consequences of inadvertent water damage would include serious damage to sensitive contents and/or major interruption to business.Type B pre-action systems will discharge water onto the seat of a fire when a
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS727332008CODEOFPRACTICEFORTHEOPERATIONOFFIREPROTECTIONMEASURESPART3ELECTRICALACTUATIONOFPREACTIONWATERMISTANDSPRINKLERSYSTEMS

链接地址:http://www.mydoc123.com/p-546667.html