BS 6907-2-1988 Electrical installations for open-cast mines and quarries - General recommendations for protection against direct contact and electric shock《露天矿和采石矿的电气装置 第2部分 防止直接接触.pdf
《BS 6907-2-1988 Electrical installations for open-cast mines and quarries - General recommendations for protection against direct contact and electric shock《露天矿和采石矿的电气装置 第2部分 防止直接接触.pdf》由会员分享,可在线阅读,更多相关《BS 6907-2-1988 Electrical installations for open-cast mines and quarries - General recommendations for protection against direct contact and electric shock《露天矿和采石矿的电气装置 第2部分 防止直接接触.pdf(26页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 6907-2: 1988 Electrical installations for open-cast mines and quarries Part 2: General recommendations for protection against direct contact and electric shock UDC 622.3:622.271.3:622.812.2:621.31.005:621.3 784.37:614.8BS6907-2:1988 This British Standard, having been prepared und
2、er the directionof the Mining and Quarrying Requisites StandardsCommittee, was published under the authority ofthe Board of BSI and comesintoeffect on 30 September 1988 BSI 09-1999 The following BSI references relate to the work on this standard: Committee reference MQE/23 Draft for comment 86/75881
3、 DC ISBN 0 580 16369 5 Committees responsible for this British Standard The preparation of this British Standard was entrusted by the Mining and Quarrying Requisites Standards Committee (MQE/-) to Technical Committee MQE/23, upon which the following bodies were represented: Associated Offices Techni
4、cal Committee British Coal China Clay Association Electric Cable Makers Confederation Electrical Contractors Association Engineering Equipment and Materials Users Association Federation of Civil Engineering Contractors Federation of Manufacturers of Construction Equipment and Cranes Health and Safet
5、y Executive Independent Engineering Insurers Committee Institution of Mining and Metallurgy Amendments issued since publication Amd. No. Date of issue CommentsBS6907-2:1988 BSI 09-1999 i Contents Page Committees responsible Inside front cover Foreword iii Section 1. General 1 Scope 1 Section 2. Prot
6、ection against electric shock in normal service 2 Protection against direct contact by limitation of voltage 2 3 Complete protection by means of barriers or enclosures 2 4 Protection from contact with overhead line conductors 3 Section 3. Protection against electric shock in case of a fault 5 Genera
7、l 4 6 Power systems 4 7 Protective measures for TN-S systems 7 8 Protective measures for TT systems 7 9 Protective measures for IT systems 8 10 Earth fault current limitation devices 8 11 Earthing arrangements and protective conductors 9 Section 4. Protection against overcurrent and fault current 12
8、 General 14 13 Types of protective device 14 14 Automatic interruption: protection against overcurrent due to overload 14 15 Automatic interruption: protection against short-circuits 15 16 Co-ordination of overcurrent and short-circuit protection 16 17 Limitation of overcurrent by nature of the sour
9、ce 16 Appendix A Selection of factor k for calculating the minimum cross-sectional area of protective conductors 17 Figure 1 Power system TN-S with separate neutral and protective conductors throughout the system 5 Figure 2 Power system TT 5 Figure 3 Power system IT with independent earth electrodes
10、 6 Figure 4 Power system IT with common earth electrode 6 Figure 5 Power system IT using external TT or TN system as a source 6 Figure 6 Illustration of the elements of a typical earthing arrangement 9 Table 1 Minimum size of earthing conductors 10 Table 2 Selection of minimum cross-sectional area f
11、or protective conductors 12 Table 3 Minimum cross-sectional area of aerial and suspended protective conductors 12 Table 4 Minimum cross-sectional area of supplementary equipotential bonding conductors 13 Table 5 Values of k for insulated protective conductors not incorporated incables and not bunche
12、d with cables or for bare protective conductors in contact with cable covering 17 Table 6 Values of k for protective conductor as core in a cable or bunchedwithcables 17 Table 7 Values of k for protective conductor as a sheath or armour of a cable 18BS6907-2:1988 ii BSI 09-1999 Page Table 8 Values o
13、f k for bare protective conductors where there is no riskofdamage to any neighbouring material by the temperatures indicated 18 Publications referred to Inside back coverBS6907-2:1988 BSI 07-1999 iii Foreword This Part of BS6907 has been prepared under the direction of the Mining and Quarrying Requi
14、sites Standards Committee. BS6907 is based on the International Electrotechnical Commissions publication IEC621 “Electrical installations for outdoor sites under heavy conditions (including open-cast mines and quarries)” and, like that publication, is published in Parts as follows. Part 1: Glossary;
15、 Part 2: General recommendations for protection against direct contact and electric shock; Part 3: Recommendations for equipment and ancillaries; Part 4: Recommendations for winning, stacking and processing machinery, pumps and low signal level and communications systems; Part 5: Recommendations for
16、 operation. BS6907 sets out the guiding principles for the installation and operation of electrical equipment so as to ensure safety of persons, livestock, property and the proper functioning of the plant. It applies to the installation and operation of electrical apparatus and systems associated wi
17、th outdoor sites under heavy conditions, including open-cast mines, quarries, stockpiles, etc. It applies particularly to electrical apparatus and systems used for the following: a) winning, stacking and primary processing machinery; b) secondary processing machinery; c) conveyor systems; d) pumping
18、 and water supply systems; e) movable railway systems; f) control, signal, supervisory and communication systems. BS6907 does not cover temporary and provisional places of work in the open, such as building sites and earth-moving sites, unless the equipment used is similar to that used in surface mi
19、ning applications. It takes account of British practice, electrical regulations and law and thereby differs in several respects from the IEC publication. Both cover a subject not previously the subject of an International Standard or a British Standard. A British Standard does not purport to include
20、 all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pagesi t
21、oiv, pages1to18, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover.iv blankBS6907-2:1988 BSI 09-1999 1 Section 1. General 1 Scope This Part of BS
22、6907 gives recommendations for protection against direct contact and electric shock for all installations in normal service, and in cases of fault, overcurrent and fault current. For winning, stacking and processing machinery, pumps and low signal level and communications systems, exemptions from th
23、ese recommendations and supplementary recommendations are given in BS6907-4, which should, therefore, be read in conjunction with this Part. The recommendations given for low voltage installations are essentially from the IEE “Regulations for Electrical Installations” (the Wiring Regulations), as ap
24、plicable. NOTE 1A glossary of terms used in this standard is given in BS6907-1. NOTE 2The titles of the publications referred to in this standard are listed on the inside back cover.BS6907-2:1988 2 BSI 09-1999 Section 2. Protection against electric shock in normal service 2 Protection against direct
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS690721988ELECTRICALINSTALLATIONSFOROPENCASTMINESANDQUARRIESGENERALRECOMMENDATIONSFORPROTECTIONAGAINSTDIRECTCONTACTANDELECTRICSHOCK

链接地址:http://www.mydoc123.com/p-546354.html