BS 6753-1986 Specification for shotbolts (solenoid operated) for guarding machinery《防护装置用(电磁操纵)射钉规范》.pdf
《BS 6753-1986 Specification for shotbolts (solenoid operated) for guarding machinery《防护装置用(电磁操纵)射钉规范》.pdf》由会员分享,可在线阅读,更多相关《BS 6753-1986 Specification for shotbolts (solenoid operated) for guarding machinery《防护装置用(电磁操纵)射钉规范》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS6753:1986 Specification for Shotbolts (solenoid operated) for guarding machinery UDC 621.882.6:621.318.371BS6753:1986 This BritishStandard, having been prepared under the directionof the Machinery andComponents Standards Committee, was published underthe authority of the BoardofBS
2、I and comesintoeffecton 28November1986 BSI12-1999 The following BSI references relate to the work on this standard: Committee reference MCE/3 Draft for comment85/70203 DC ISBN 0 580 15460 2 Committees responsible for this BritishStandard The preparation of this BritishStandard was entrusted by the M
3、achinery and Components Standards Committee (MCE/-) to Technical Committee MCE/3, upon which the following bodies were represented: Association of British Insurers British Aggregate Construction Materials Industries British Coal British Federation of Printing Machinery and Supplies Ltd. British Plas
4、tics Federation British Rubber Manufacturers Association British Textile Employers Association British Textile Machinery Association Chemical Industries Association Electric Cable Makers Confederation Engineering Employers Federation Engineering Equipment and Materials Users Association Federation o
5、f Bakers Health and Safety Executive Industrial Safety (Protective Equipment) Manufacturers Association Institution of Mechanical Engineers Institution of Occupational Safety and Health Institution of Production Engineers Machine Tool Industry Research Association Mechanical Handling Engineers Assoc
6、iation Metalforming Machinery Makers Association Limited National Federation of Clay Industries Ltd. Process Plant Association Rotating Electrical Machines Association (BEAMA Ltd.) Society of Laundry Engineers and Allied Trades Limited Trades Union Congress Amendments issued since publication Amd. N
7、o. Date of issue CommentsBS6753:1986 BSI 12-1999 i Contents Page Committees responsible Inside front cover Foreword ii 1 Scope 1 2 Dimensions 1 3 Performance 1 4 Electrical requirements 1 5 Corrosion protection 1 6 Shape of bolt nose 1 7 Spring force 1 Figure 1 Shotbolt 2 Table 1 Dimensions of shotb
8、olts 2 Publications referred to Inside back coverBS6753:1986 ii BSI 12-1999 Foreword This BritishStandard has been prepared under the direction of the Machinery and Components Standards Committee following a proposal from the Machine Tool Industry Research Association. The standard deals with shotbo
9、lts which are primarily used for locking opening guards in the closed position by means of spring force, the bolt being retracted electromagnetically by the operation of a solenoid. The aim of the standard is to reduce variety in shotbolts and thereby facilitate their interchangeability and replacem
10、ent. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document compr
11、ises a front cover, an inside front cover, pagesi andii, pages1 and 2, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover.BS6753:1986 BSI 12-1999
12、1 1 Scope This BritishStandard specifies fixing dimensions, envelope dimensions, electrical requirements and performance requirements for three sizes of shotbolts for use on guards for safeguarding machinery. This standard is not intended to apply to the safeguarding of machinery used in domestic ap
13、pliances. NOTEThe titles of the publications referred to in this standard are listed on the inside back cover. 2 Dimensions Dimensions of shotbolts shall be as given in Table 1. 3 Performance The shotbolt action shall be designed and installed in such a way that the unpowered state is the guard-lock
14、ed state, i.e.power retract, spring extend. NOTEThe action should be so designed as to minimize the possibility of failure in the unlocked retracted state. 4 Electrical requirements 4.1 Supply voltage Shotbolts shall be designed to operate from the following supplies: a) a.c.:48V,110V or240V,50Hz b)
15、 d.c.:24V,48V,110V or240V. 4.2 Rating Shotbolts shall be continuously rated within an ambient temperature range of+5 C and40 C. 4.3 Wiring connections 4.3.1 The wiring shall either: a) pass through a conduit entry to terminals within the shotbolt; NOTE 1This is the preferred method. NOTE 2For machin
16、e tool applications, a terminal box entry of M20 1.5 (seeBS4568) is generally suitable. or, b) where monitoring is not required, terminate in a three-pin plug, complying with BS6361, within or integral with the bolt. 4.3.2 Terminations shall comply with BS2771-1 1) . 4.4 Switches Where electromechan
17、ical switches are used to monitor that the bolt is shot, position switches having positive opening operation complying with BS4794-2.20 shall be fitted. NOTE 1These switches may be either of the direct operating type or of a type which combines snap action with positive opening operation. Such switc
18、hes can have changeover contacts. NOTE 2The primary aim of monitoring is to ensure that the bolt is shot. Monitoring of bolt retraction is secondary and, although not always required, is recommended. NOTE 3The action of bolt withdrawal should positively operate one switch. 4.5 Solenoids 4.5.1 The so
19、lenoid shall be capable of operating at 10%of its rated voltage. If transient voltage protection to protect the device switching the solenoid from damage is not fitted, this shall be stated by the manufacturer. 4.5.2 Solenoids shall be d.c. operated. If the supply is a.c. a rectifier shall be incorp
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS67531986SPECIFICATIONFORSHOTBOLTSSOLENOIDOPERATEDFORGUARDINGMACHINERY 防护 装置 用电 操纵 规范 PDF

链接地址:http://www.mydoc123.com/p-546221.html