BS 6522-1984 Methods for determination of percentage water saturation of insulating oil《绝缘油水饱和百分比测定方法》.pdf
《BS 6522-1984 Methods for determination of percentage water saturation of insulating oil《绝缘油水饱和百分比测定方法》.pdf》由会员分享,可在线阅读,更多相关《BS 6522-1984 Methods for determination of percentage water saturation of insulating oil《绝缘油水饱和百分比测定方法》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS6522:1984 Method for Determination of percentage water saturation of insulating oil UDC 621.315.615.2:665.767:543.812:536.423.45BS6522:1984 This BritishStandard, having been prepared under the directionof the General Electrotechnical Engineering Standards Committee, was published
2、under the authority ofthe Board of BSI and comes intoeffect on 31August1984 BSI 11-1999 The following BSI references relate to the work on this standard: Committee referenceGEL/115 Draft for comment80/29335DC ISBN 0 580 13950 6 Committees responsible for this BritishStandard The preparation of this
3、BritishStandard was entrusted by the General Electrotechnical Engineering Standards Committee (GEL/-) to Technical CommitteeGEL/115 upon which the following bodies were represented: Association of Consulting Engineers Beama Transmission and Distribution Association British Railways Board ERA Technol
4、ogy Ltd. Electricity Supply Industry in England and Wales Institute of Petroleum Institution of Electrical Engineers London Transport Executive The following bodies were also represented in the drafting of the standard, through subcommittees and panels: British Lubricants Federation Limited Electric
5、 Cable Makers Confederation Electric Cable Makers Confederation Supertension Cables Group Amendments issued since publication Amd. No. Date of issue CommentsBS6522:1984 BSI 11-1999 i Contents Page Committees responsible Inside front cover Foreword ii 1 Scope 1 2 Principle 1 3 Apparatus 1 4 Sample pr
6、eparation 1 5 Procedure 1 6 Calculation of results 2 7 Precision 2 Figure 1 Arrangement of equipment for the measurement of dew-point 3 Publications referred to Inside back coverBS6522:1984 ii BSI 11-1999 Foreword This BritishStandard has been prepared under the direction of the General Electrotechn
7、ical Engineering Standards Committee. The degradation of cellulosic materials used in oil filled equipment such as transformers is affected by their water content. This can only be estimated from a measurement of the water content of the oil. The presence of water also adversely affects the electric
8、al insulating properties of the oil and cellulose, and it is therefore desirable to maintain the water content at a low level. The determination of absolute water content in insulating oil has in recent years generally been carried out by the Karl Fischer method. This determination requires consider
9、able care and skill and may present additional difficulties if carried out on site. Moreover, the information obtained has to be interpreted in the light of experience; a moderate water content may suggest potential trouble with an unoxidized oil but may be innocuous when found in an oxidized oil. T
10、he method described in this standard determines the percentage saturation of the oil rather than its absolute water content. If the percentage saturation of a sample of oil from a transformer is determined at, say, three temperatures, this will enable a curve to be drawn, using extrapolation if nece
11、ssary, showing the percentage saturation as a function of oil temperature over the range of temperatures found in the oil of that transformer in operation. This immediately reveals whether water condensation is likely, i.e.whether100% saturation may be approached; such conditions may arise at the co
12、ldest regions of the oil, e.g.in the conservator. This information is independent of the age or state of the oil. In addition, since if oil and cellulose are in water equilibrium and at the same temperature their percentage saturations are approximately equal, the curve produced as described above,
13、showing percentage saturation against temperature for the oil, may be regarded as applying also to the paper, etc. in the transformer over the range of temperature found in the paper. While this application to the paper is subject to several sources of error, the indication of paper condition so giv
14、en is much more revealing than can possibly be obtained from an absolute water determination by the Karl Fischer method. NOTEIt has been assumed in the drafting of this BritishStandard that all users of this standard will, if not themselves fully trained, at least be under the supervision of a respo
15、nsible trained person who will be familiar with all normal laboratory practice and engineering practice as appropriate and safety precautions, and that all such precautions will be observed. A British Standard does not purport to include all the necessary provisions of a contract. Users of British S
16、tandards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pagesi andii, pages1 to4, an inside back cover and a back cover. This s
17、tandard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover.BS6522:1984 BSI 11-1999 1 1 Scope This BritishStandard describes a method of test for the determination of the percentage water saturation o
18、f insulating oil. The method and apparatus described enables the percentage saturations of oil to be determined at temperatures up to60 C provided the dew-point does not exceed ambient temperature. NOTEThe titles of the publications referred to in this standard are listed on the inside back cover. 2
19、 Principle The method relies on the fact that if a volume of air and a volume of oil are in water equilibrium and at the same temperature then their percentage water saturations are equal. In the apparatus described, a small volume of air is circulated through a tubular semi-permeable membrane, imme
20、rsed in a sample of the oil to be examined. After a short time, the air has the same percentage saturation as the oil. The dew-point of the air is measured and converted to percentage saturation; this value is then the percentage saturation of the oil sample with water at that temperature. The oil m
21、ay be heated to obtain percentage saturation at a number of temperatures. 3 Apparatus 3.1 Air-tight test vessel, for a sample of oil sufficient to immerse the membrane completely. NOTEA test vessel of volume500mL has been found satisfactory. 3.2 Dew-point hygrometer, to measure the dew-point down to
22、 40 C. NOTEA suitable instrument has an accuracy of about 0.5 C from ambient temperature down to20 C but the accuracy may fall at lower dew-points. A suitable hygrometer uses a light beam directed on to a cooled mirror and reflected on to a photo-transistor. Attenuation of the light beam by a deposi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS65221984METHODSFORDETERMINATIONOFPERCENTAGEWATERSATURATIONOFINSULATINGOIL 绝缘 油水 饱和 百分比 测定 方法 PDF

链接地址:http://www.mydoc123.com/p-546095.html