BS 5591-1978 Methods of test for determination of ionic impurities in electrical insulating materials by extraction with liquids《用液体萃取法测定电绝缘材料中离子杂质的试验方法》.pdf
《BS 5591-1978 Methods of test for determination of ionic impurities in electrical insulating materials by extraction with liquids《用液体萃取法测定电绝缘材料中离子杂质的试验方法》.pdf》由会员分享,可在线阅读,更多相关《BS 5591-1978 Methods of test for determination of ionic impurities in electrical insulating materials by extraction with liquids《用液体萃取法测定电绝缘材料中离子杂质的试验方法》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS5591:1978 IEC589:1977 Incorporating Amendment No.1 Methods of test for Determination of ionic impurities in electrical insulating materials by extraction with liquids UDC 621.315.611.001.4:543.056:543.257.5BS5591:1978 This BritishStandard, having been prepared under the directiono
2、f the General Electrotechnical Engineering Standards Committee, was published under the authorityofthe Executive Boardon 30June1978 BSI 12-1999 The following BSI references relate to the work on this standard: Committee reference GEL/16 Draft for comment 77/20330 DC ISBN 0 580 10211 4 Cooperating or
3、ganizations The General Electrotechnical Engineering Standards Committee, under whose direction this BritishStandard was prepared, consists of representatives from the following Government departments and scientific and industrial organizations: Associated Offices Technical Committee British Approva
4、ls Service for Electric Cables Ltd. British Electrical and Allied Manufacturers Association (BEAMA) British Radio Equipment Manufacturers Association British Steel Corporation Department of Energy (Electricity) Electric Cable Makers Confederation Electrical Contractors Association Electrical Contrac
5、tors Association of Scotland Electrical Research Association* Electricity Supply Industry in England and Wales* Electronic Components Industry Federation Electronic Engineering Association Engineering Equipment Users Association Health and Safety Executive Home Office Institution of Electrical Engin
6、eers Ministry of Defence National Coal Board Oil Companies Materials Association Post Office* Telecommunication Engineering and Manufacturing Association (TEMA) The organizations marked with an asterisk in the above list, together with the following, were directly represented on the committee entrus
7、ted with the preparation of this BritishStandard: British Industrial Ceramic Manufacturers Association Electrical and Electronic and Insulation Association (BEAMA) Glass Textile Association Rotating Electrical Machines Association (BEAMA) Amendments issued since publication Amd. No. Date of issue Co
8、mments 2789 April 1979 Indicated by a sideline in the marginBS5591:1978 BSI 12-1999 i Contents Page Cooperating organizations Inside front cover National foreword ii 1 Scope and object 1 2 Definitions and units 1 3 Apparatus 1 4 Procedure 1 5 Calculation 2 6 Test report 2 Appendix A Platinized plati
9、num electrodes Inside back cover Appendix B KCl Standard solutions Inside back coverBS5591:1978 ii BSI 12-1999 National foreword This BritishStandard has been prepared under the direction of the General Electrotechnical Engineering Standards Committee. It is identical with IECPublication589:1977 “Me
10、thods of test for the determination of ionic impurities in electrical insulating materials by extraction with liquids”, published by the International Electrotechnical Commission (IEC). The text of the IEC Publication has been accepted as suitable for publication, without deviation, as a BritishStan
11、dard. WARNING NOTE. Attention is drawn to the health hazard which may arise when this test is performed (seenote3 to4.2.1). A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance
12、with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pagesi andii, pages1 and2, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had ame
13、ndments incorporated. This will be indicated in the amendment table on the inside front cover.BS5591:1978 BSI 12-1999 1 1 Scope and object The purpose of this standard is to determine whether or not ionizable soluble organic and/or inorganic materials are present in electrical insulating materials.
14、Their presence is confirmed by the increase in volume conductivity of the liquid extract and the test is considered to have particular significance when applied to electrical insulating materials which are to be immersed in coolants or impregnants. 2 Definitions and units The volume conductivity of
15、a liquid extract exis the difference between the volume conductivity of the extract solution and the volume conductivity of the control sample (blank sample). The SI unit of the volume conductivity is Sm 1 . In practice, the unit Scm 1is often used. 3 Apparatus 250ml conical flasks (Erlenmeyer) with
16、 reflux condensers having acid resistant and alkali resistant glass; conductivity cell with known cell constant k (m 1 ) or (cm 1 ); a bridge or other measuring device capable of measuring resistances with an accuracy of5%. In the case of aqueous extracts, this measuring device shall permit the meas
17、urement of resistances up to1M7 at frequencies between50Hz and3000Hz. In the case of organic extracts, the measuring device shall permit the measurement of resistances up to1T7 using not more than100V. d.c. NOTEIf unknown, the cell constant k is determined by means of a standard KCl solution of know
18、n conductivity, in accordance with Appendix B. 4 Procedure 4.1 Aqueous extract 4.1.1 Test water The quality of the test water has a considerable influence on the result of the test. The volume conductivity of the test water preparing the aqueous extracts shall beu210 4Sm 1 . The pH value of the test
19、 water shall be between6.8 and7.2. The test water can be made by means of an ion-exchanger or by using double distilled water of the recommended pH value. NOTEAttention is drawn to the effect of carbon dioxide. The pH of newly prepared water will change to between5.7 and5.9 after the water has been
20、exposed to air for a short time. If the change due to carbon dioxide has produced a pH of not less than6.4, the water can be restored to pH=7 by blowing pure nitrogen through it for a short time. The pH will remain within the required limits for a long time if the water is stored in polyethylene fla
21、sks from which carbon dioxide is excluded. 4.1.2 Preparation of the aqueous extract If not otherwise specified, the aqueous extract is to be prepared as follows. Take a test specimen weighing approximately20g into pieces of suitable dimensions. Weigh5 0.1g of these small pieces into three flasks fit
22、ted with reflux condensers, as described in Clause3, and add100ml of test water. A fourth flask and condenser is used for the blank control sample. The water in the four flasks shall be kept boiling gently for60 5min and then cooled in the flasks to room temperature. Precautions shall be taken to av
23、oid admission of carbon dioxide. 4.1.3 Measurements Before measuring the extracts, the resistance of the blank control sample shall be determined. The aqueous extract is decanted from the test specimens into the conductivity cell for measuring immediately. The conductivity cell shall be rinsed twice
24、 with the extract. The measurement of the resistance shall be carried out on each extract separately. The measurements shall be carried out at23 1 C. NOTEIt is essential to ensure that during the taking, storing and manipulation of samples, specimens and test portions intended for the conductivity t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS55911978METHODSOFTESTFORDETERMINATIONOFIONICIMPURITIESINELECTRICALINSULATINGMATERIALSBYEXTRACTIONWITHLIQUIDS

链接地址:http://www.mydoc123.com/p-545242.html