1、BRITISH STANDARD BS3680-2A: 1995 ISO9555-1: 1994 Measurement of liquid flow in open channels Part 2: Dilution methods Part 2A: GeneralBS3680-2A:1995 This British Standard, having been prepared under the directionof the Electrotechnical Sector Board, was published underthe authority of the Standards
2、Board and comes into effect on 15 January1995 BSI 06-1999 The following BSI references relate to the work on this standard: Committee reference PCL/3 Draft for comment 92/34385 DC ISBN 0 580 23541 6 Committees responsible for this British Standard The preparation of this British Standard was entrust
3、ed by the Electrotechnical Sector Board to Technical Committee PCL/3, upon which the following bodies were represented: Clyde River Purification Board Department of the Environment Institute of Measurement and Control Institution of Water and Environmental Management National Rivers Authority Water
4、Services Association of England and Wales Welsh Office The following bodies were also represented in the drafting of the standard, through subcommittees and panels: Institute of Hydrology Water Research Centre Amendments issued since publication Amd. No. Date CommentsBS3680-2A:1995 BSI 06-1999 i Con
5、tents Page Committees responsible Inside front cover National foreword ii Introduction 1 1 Scope 1 2 Normative reference 1 3 Definitions 1 4 Symbols and units 4 5 Principles of the different dilution methods 5 6 Characteristics common to both methods 6 7 Choice of tracer 11 8 Choice of measuring rea
6、ch 12 9 Procedure for the constant rate injection method 20 10 Procedure for the sudden injection method 25 11 Comparison between the two dilution methods 30 12 Estimation of uncertainties 32 Annex A (normative) Standard dilutions using pipettes and flasks 46 Annex B (normative) Standard dilution ra
7、nges obtained with a micrometer-type microburette 47 Annex C (normative) Analysis for variance as a test of non-randomness 49 Annex D (informative) Bibliography 50 Figure 1 Relation between and c 2 12 Figure 2 Curves of appearance and disappearance of tracer for a sudden injection Shapes of curves o
8、f concentration against time and distance 18 Figure 3 Curves of appearance and disappearance of tracer used to determine a suitable duration of injection T ifor a gauging by the constant rate injection method Shapes of curves of concentration against time and distance 19 Figure 4 Constant level tank
9、 for the injection of tracer solution at constant rate 22 Figure 5 Use of a constant-rate pump for injection of tracer solution at constant rate 23 Figure 6 Mariotte constant head vessel 24 Figure 7 Floating siphon device 24 Figure 8 Typical sampling curves 27 Figure 9 Obtaining mean samples 28 Figu
10、re 10 Obtaining several mean samples 31 Figure 11 Pump with manifold for multiple sampling 32 Table 1 Values of the coefficient k 15 Table B.1 Preparation of standard dilution ranges using a micrometer-type microburette 48 Table B.2 Micrometer turns for ranges with mid-values N 0 48 Table C.1 Instru
11、ment readings 49 Table C.2 Sums of squares of values from Table C.1 49 Table C.3 Instrument readings 50 Table C.4 Sum of squares of values from Table C.3 50 List of references Inside back coverBS3680-2A:1995 ii BSI 06-1999 National foreword This Part of BS3680 has been prepared under the direction o
12、f the Electrotechnical Sector Board. It is identical with ISO9555-1:1994 Measurement of liquid flow in open channels Tracer dilution methods for the measurement of steady flow Part1: General, published by the International Organization for Standardization (ISO). This is one of a series of Parts of B
13、S3680 on dilution methods, as follows: Part 2A:1994: General; Part 2B:1993: Radioactive tracers; Part 2C:1993: Chemical tracers; Part 2D:1993: Fluorescent tracers. These four Parts of BS3680 supersede BS3680-2A:1964, BS3680-2B:1986, and BS3680-2C:1983 which are withdrawn. Cross-references The Techni
14、cal Committee has reviewed the provisions of ISO772:1988, to which normative reference is made in the text, and has decided that they are acceptable for use in conjunction with this standard. Informative reference is also made to the following standard: A British Standard does not purport to include
15、 all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. ISO 8363:1986 BS3680 Measurement of liquid flow in open channels Part 3G:1990 General g
16、uidelines for the selection of methods Summary of pages This document comprises a front cover, an inside front cover, pagesi and ii, pages1to50, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated
17、 in the amendment table on the inside front cover.ISO9555-1:1994(E) BSI 06-1999 1 Introduction The former standard series ISO555 was subdivided into parts on the basis of the method of field measurement, i.e.constant-rate injection method and integration (sudden injection) method. Since the choice o
18、f the type of tracer to be used in a field measurement will often depend on the expertise and the laboratory facilities available, this new series of standards ISO9555 is divided into parts based on the type of tracer used. This revision has enabled the unnecessary repetition of text of the various
19、parts to be avoided and will, it is hoped, prove to be a more convenient form of presentation for the user. ISO9555 deals with the measurement of steady flow in open channels by dilution methods using tracers. The methods described may also be applied to the measurement of slowly varying flow, but t
20、hey may only be used when flow conditions ensure adequate mixing of the injected solution throughout the flow. For the measurement of very large flows, tracer methods can be onerous in terms of tracer costs and measurement times. However, the use of tracers often reduces danger to personnel during f
21、lood periods. ISO9555-1 presents the general principles of the methods of constant rate injection and integration (sudden injection). ISO9555-2, ISO9555-3 and ISO9555-4 deal with the specific aspects of the use of radioactive, chemical and fluorescent tracers, respectively, as well as specific analy
22、tical procedures. This approach has been adopted for the following reasons: to facilitate subsequent updating, additions or revisions which concern only ISO9555-2, ISO9555-3 or ISO9555-4; to provide a more practical document for the user, who is often obliged to choose the tracer best suited to the
23、available analytical equipment. 1 Scope This part of ISO9555 concerns principles of the constant rate injection method and the sudden injection method (integration method), and the principles of injection, sampling and analysis which apply for all types of tracer. It is important to note that the tr
24、acers used and their concentrations should be compatible with the legislation of each country regarding the occasional and short-duration discharges of foreign substances into natural waters. They should also take into account possible short-term or long-term influences on flora and fauna, both natu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS36802A1995MEASUREMENTOFLIQUIDFLOWINOPENCHANNELSDILUTIONMETHODSGENERAL 明渠 测量 部分 稀释 总则 PDF

链接地址:http://www.mydoc123.com/p-543817.html