《BS 2782-7 Method 720B-1979 Methods of testing plastics - Rheological properties - Cup flow of phenolic and alkyd moulding materials《塑料试验方法 第7部分 流变性能 试验方法720B 苯酚与醇酸模制材料的杯模流动溢法流动性》.pdf》由会员分享,可在线阅读,更多相关《BS 2782-7 Method 720B-1979 Methods of testing plastics - Rheological properties - Cup flow of phenolic and alkyd moulding materials《塑料试验方法 第7部分 流变性能 试验方法720B 苯酚与醇酸模制材料的杯模流动溢法流动性》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS2782-7: Method720B: 1979 Methods of testing Plastics Part 7: Rheological properties Method 720B: Cup flow of phenolic and alkyd moulding materials IMPORTANT NOTE. Before reading this method it is essential to read the foreword, general introduction and instructions to BS2782, issu
2、ed separately. UDC 678.5/.8:678.01:532.135BS2782-7:Method720B:1979 This British Standard, having been prepared under the directionof the Plastics StandardsCommittee, was published under the authority ofthe Executive Board and comesinto effect on 31August1979 BSI11-1999 The following BSI references r
3、elate to the work on this standard: Committee reference PLC/17 Draft for comment78/55155 DC ISBN 0 580 10903 8 A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a Britis
4、h Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pagesi andii, pages1 and 2 and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be
5、 indicated in the amendment table on the inside front cover. Amendments issued since publication Amd. No. Date of issue CommentsBS2782-7:Method720B:1979 BSI 11-1999 i Contents Page 0 Introduction 1 1 Scope 1 2 Reference 1 3 Principle 1 4 Apparatus 1 5 Procedure 1 6 Expression of results 2 7 Test rep
6、ort 2 Figure 1 Detail of cup flow mould 2ii blankBS2782-7:Method720B:1979 BSI 11-1999 1 0 Introduction This method which has been prepared under the direction of the Plastics Standards Committee is similar in technical content to method105B of BS2782:1970, which is being withdrawn. The method is for
7、 assessing the flow properties of phenolic and alkyd moulding materials. It is not suitable for fast-curing moulding materials. WARNING NOTE. This method does not necessarily detail all the precautions necessary to meet the requirements of the Health and Safety of Work etc Act1974. Attention should
8、be paid to any necessary safety precautions, and the method should only be operated by trained personnel. 1 Scope This method describes a procedure for assessing the flow properties of phenolic and alkyd moulding materials. 2 Reference The following standards publication is referred to in this stand
9、ard. BS593, Laboratory thermometers. 3 Principle The flow properties of moulding materials are assessed by measuring the time taken for a mould in the form of a cup of specified dimensions to close under a specified pressure and temperature. 4 Apparatus The following apparatus is required. 4.1 Stand
10、ard compression mould of form and dimensions shown in Figure 1. The mould shall comply in all respects with the details shown in thefigure. A pocket for the thermometer shall be provided in the die to reach within13mm of the outside wall of the moulding. The mould shall be made of good quality steel
11、 as usually used for moulds, e.g.high carbon, high chromium, air-hardening alloy steel, hardened to45HRC to48HRC(500HV to550HV). The surfaces marked “X” in Figure 1shall be smooth and polished. The final polishing shall be in the line of the tool draw, i.e.parallel to the direction of movement of th
12、e press. The method of heating the mould shall be such as to maintain a uniform temperature within 1 C of the specified temperature. 4.2 Compression moulding press, capable of exerting and maintaining the pressure required. The force on the mould shall be100 5kN, calculated according to the expressi
13、on appropriate to the type of press in use. In the case of an up-stroking press F = Ap mg In the case of a down-stroking press the force on the mould is given by the following expression, the symbols having the same meaning as previously. F = Ap + mg The cross-sectional area of the ram shall be dete
14、rmined from its measured diameter. The pressure gauge shall be checked for accuracy and shall be connected to the press inlet pipe. The line pressure shall not vary by more than3% during the course of the test. The inlet of the hydraulic supply shall be choked with a bored nipple so that the press r
15、am travels130mm in a period of between4s and5s when the valve is fully opened, as at the beginning of the test. 4.3 Thermometer complying with the requirements of BS593. 4.4 Timing device, graduated in divisions of0.5s or less. 5 Procedure Ensure that the mould is clean and polished. Heat the mould
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS27827METHOD720B1979METHODSOFTESTINGPLASTICSRHEOLOGICALPROPERTIESCUPFLOWOFPHENOLICANDALKYDMOULDINGMATERIALS

链接地址:http://www.mydoc123.com/p-543283.html