BS 2782-4 Method 454G-1996 Methods of testing plastics - Chemical properties - Polymer dispersions - Determination of sieve residue (gross particle and coagulum content)《塑料试验方法 第4部.pdf
《BS 2782-4 Method 454G-1996 Methods of testing plastics - Chemical properties - Polymer dispersions - Determination of sieve residue (gross particle and coagulum content)《塑料试验方法 第4部.pdf》由会员分享,可在线阅读,更多相关《BS 2782-4 Method 454G-1996 Methods of testing plastics - Chemical properties - Polymer dispersions - Determination of sieve residue (gross particle and coagulum content)《塑料试验方法 第4部.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 2782-4: Method 454G: 1996 ISO 4576:1996 Methods of testing Plastics Part 4: Chemical properties Method 454G: Polymer dispersions Determination of sieve residue (grossparticle and coagulum content) ICS 83.080BS2782-4:Method454G:1996 This British Standard, having been prepared unde
2、r the direction of the Sector Board for Materials and Chemicals, was published under the authority of the Standards Board and comes into effect on 15 October 1996 BSI 11-1998 The following BSI references relate to the work on this standard: Committee reference PRI/21 Draft for comment 94/341937 DC I
3、SBN 0 580 26043 7 Committees responsible for this British Standard The preparation of this British Standard was entrusted to Technical Committee PRI/21, Testing of plastics, upon which the following bodies were represented: The British Apparel and Textile Confederation British Plastics Federation De
4、partment of the Environment (Building Research Establishment) Department of Trade and Industry (National Physical Laboratory) Electrical and Electronic Insulation Association GAMBICA (BEAMA Ltd.) Institute of Materials Ministry of Defence Packaging and Industrial Films Association PIRA International
5、 RAPRA Technology Ltd. Royal Society of Chemistry Amendments issued since publication Amd. No. Date CommentsBS2782-4:Method454G:1996 BSI 11-1998 i Contents Page Committees responsible Inside front cover National foreword ii 1 Scope 1 2 Normative references 1 3 Principle 1 4 Reagents 1 5 Apparatus 1
6、6 Sampling 1 7 Procedure 1 8 Expression of results 2 9 Precision 2 10 Test report 2 Figure 1 Example of filtration apparatus 3 List of references Inside back coverBS2782-4:Method454G:1996 ii BSI 11-1998 National foreword This British Standard has been prepared by Technical Committee PRI/21 and is id
7、entical with ISO 4576:1996 Plastics Polymer dispersions Determination of sieve residue (gross particle and coagulum content), published by the International Organization for Standardization (ISO). The Technical Committee has reviewed the provisions of ISO3310-1:1990 to which normative reference is m
8、ade in the text and has decided that they are acceptable for use in conjunction with this standard. A related British Standard is BS410:1986 Specification for test sieves. NOTEInternational and European Standards as well as overseas standards, are available from Customer Services, BSI, 389 Chiswick
9、High Road, London, W4 4AL. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Cross-referenc
10、es Publication referred to Corresponding British Standard ISO 123:1985 BS 6057 Rubber lattices. Part 2:1987 Sampling (Identical) ISO 842:1984 BS 4726:1986 Methods for sampling raw materials for paints and varnishes (Identical) Summary of pages This document comprises a front cover, an inside front c
11、over, pages i and ii, pages1 to 3, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on theinside front cover.BS2782-4:Method454G:1996 BSI 11-1998 1 1 Scope This Internati
12、onal Standard specifies a method of determining the sieve residue (gross particle and coagulum content) of polymer dispersions, i.e. of particles much greater in diameter (for example 10 or 100 times) than the mean diameter of the other particles. This determination is carried out by sieve analysis.
13、 The sieves used depend on the type of dispersion under test and are in consequence to be specified, or agreed upon by the interested parties, for each dispersion or group of closely related dispersions. This International Standard refers only to coagulum-type content. Skinned material and fragments
14、 of skin larger than 5 mm are avoided while taking the sample (see clause 6) 2 Normative references The following standards contain provisions which, through reference in this text, constitute provisions of this International Standard. At the time of publication, the editions indicated were valid. A
15、ll standards are subject to revision, and parties to agreements based on this International Standard are encouraged to investigate the possibility of applying the most recent editions of the standards indicated below. Members of IEC and ISO maintain registers of currently valid International Standar
16、ds. ISO 123:1985, Rubber latex Sampling. ISO 842:1984, Raw materials for paints and varnishes Sampling. ISO 3310-1:1990, Test sieves Technical requirements and testing Part 1: Test sieves of metal wire cloth. 3 Principle The polymer dispersion is diluted with a specified volume of deionized water an
17、d filtered through a metal gauze of a specified mesh size. The residue is washed with deionized water and then dried and weighed. 4 Reagents During the analysis, use only reagents of recognized analytical grade, and deionized water or water of equivalent purity. 4.1 Surfactants, for stabilizing the
18、polymer dispersion during testing (if necessary), as agreed between the interested parties. 5 Apparatus 5.1 Test sieves (series of metal gauzes, preferably stainless steel), as specified in ISO 3310-1, in the form of discs or squares, including at least meshes with the following aperture sizes: 45 m
19、, 63 m, 90 m, 125 m and 180 m Non-metallic gauzes may be used, but this shall be indicated in the test report. 5.2 Equipment to support the wire gauzes, such as steel rings or glass funnels of equal internal diameter between 25 mm and 50 mm. 5.3 Laboratory balances, one having an accuracy of 1mg for
20、 weighing test portions of up to 200 g (or10mg for test portions between 200 g and1000g) and the other having an accuracy of0,1mg for weighing the sieve (with and without the residue). 5.4 Normal oven or vacuum oven, capable of maintaining, to 2 C, a temperature of preferably105 C, or any of the fol
21、lowing alternative temperatures if more suitable for a particular dispersion: 80 C, 125 C or 140 C The temperature for drying the sieve residue shall be selected from those given, the preferred temperature being 105 C 2 C. The temperature chosen will depend on the stability of the polymer and the pr
22、esence of any additives, and shall be in line with the temperature recommended for the determination of the residue on drying of the polymer dispersion under test. 5.5 Desiccator, big enough to hold the gauzes. 5.6 Beaker, of capacity at least 600 ml, with a lip. 5.7 Filtration apparatus, as shown i
23、n Figure 1, for instance. 6 Sampling Sampling shall be carried out in accordance with one of the methods specified in ISO 123 or ISO 842 to obtain a homogeneous sample. Visible skin and skin fragments larger than 5mm shall be carefully avoided while sampling. 7 Procedure 7.1 Weigh approximately 100
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS27824METHOD454G1996METHODSOFTESTINGPLASTICSCHEMICALPROPERTIESPOLYMERDISPERSIONSDETERMINATIONOFSIEVERESIDUEGROSSPARTICLEANDCOAGULUMCONTENT

链接地址:http://www.mydoc123.com/p-543264.html