BS 2692-2-1956 Fuses for voltages exceeding 1000 V a c Expulsion fuses《1000V以上交流电熔断器 第2部分 冲出式熔丝》.pdf
《BS 2692-2-1956 Fuses for voltages exceeding 1000 V a c Expulsion fuses《1000V以上交流电熔断器 第2部分 冲出式熔丝》.pdf》由会员分享,可在线阅读,更多相关《BS 2692-2-1956 Fuses for voltages exceeding 1000 V a c Expulsion fuses《1000V以上交流电熔断器 第2部分 冲出式熔丝》.pdf(56页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 2692-2: 1956 Incorporating Amendment Nos.1,2,3,4,5 and6 Specification for Fuses for voltages exceeding 1000Va.c. Part2: Expulsion fuses UDC 621.316.923 CONFIRMED DECEMBER 2007BS2692-2:1956 This BritishStandard, having been approved by the ElectricalIndustry StandardsCommittee and
2、endorsed by the Chairmanofthe EngineeringDivisional Council,was published under the authorityof the General Council on 30January1956 BSI 02-2000 The following BSI references relate to the work on this standard: Committee referenceELE/10/6 Draft for comment CR(ELE)7650 ISBN 0 580 02513 6 Co-operating
3、 organizations The Electrical Industry Standards Committee under whose supervision this BritishStandard was prepared, consists of representatives from the following Government departments and scientific and industrial organizations: The Government departments and scientific and industrial organizati
4、ons marked with an asterisk in the above list, together with the following, were directly represented on the committee entrusted with the preparation of the standard. Admiralty* Electric Light Fittings Association Air Ministry* Electrical Contractors Association Association of Consulting Engineers (
5、Incorporated) (Incorporated)* Electrical Contractors Association of Scotland Association of Supervising Electrical Engineering Equipment Users Association* Engineers General Post Office* British Electrical and Allied Industries Independent Cable Makers Association Research Association* Institution o
6、f Electrical Engineers British Electrical and Allied Manufacturers Ministry of Fuel and Power* Association* Ministry of Labour and National Service British Electrical Development Association (Factory Department)* British Railways, The British Transport Ministry of Supply* Commission* Ministry of Wor
7、ks Central Electricity Authority and Area National Physical Laboratory* Boards* North of Scotland Hydro-Electric Board* Cable Makers Association* Oil Companies Materials Committee* Crown Agents for Oversea Governments and Public Transport Association (Incorporated) Administrations* Radio Industry Co
8、uncil Electric Lamp Manufacturers Association War Office Association of Mining Electrical and London Transport Executive, The British Mechanical Engineers Transport Commission Engineer Surveyors Association National Coal Board High Commission of India South of Scotland Electricity Board Lloyds Regis
9、ter of Shipping Amendments issued since publication Amd. No. Date of issue Comments 2633 October1956 3625 January1960 3755 May1960 5872 July1966 611 October1970 1885 January1976 Indicated by a sideline in the marginBS2692-2:1956 BSI 02-2000 i Contents Page Co-operating organizations Inside front cov
10、er Foreword iii Section 1. General 1 Scope 1 2 Basis of specification 1 3 Definitions 2 Section 2. Rating 4 Voltage-rating 6 5 Current-rating 6 6 Breaking-capacity ratings 7 Section 3. Marking 7 Fuse-links 9 8 Current-limiting impedances 10 Section 4. Service conditions 9 Service conditions 10 Secti
11、on 5. Operation in service 10 General requirements 10 11 Liquids 11 12 Time/current characteristics 11 13 Cut-off current characteristic (for current-limiting fuses only) 11 14 Temperature-rise limits at rated current 11 Section 6. Construction 15 Components 12 16 Contacts 12 17 Fuse-links 12 18 Fus
12、e-carriers and fuse-mounts 13 19 Current-limiting impedances 13 Section 7. Type tests 20 General 13 21 Test for temperature-rise 13 22 High-voltage test: wet test for outdoor fuses 14 23 Impulse-voltage tests 15 24 Oil-penetration test for oil-tight cartridge fuse-links 16 25 Sealing test for liquid
13、 fuse-links 16 26 Weatherproof test for powder-filled cartridge-fuses for outdoor use 17 27 Tests for breaking-capacity 17 28 Criteria of failure in tests for breaking-capacity 19 Section 8. Routine tests 29 General 21 Appendix A Notes on terms in the standard relating to performance of fuses 23 App
14、endix B Selection of fuses 24 Appendix C Calculation of short-circuit fault-currents 27 Appendix D Measurement of prospective current and cut-off current 27 Appendix E Measurement of power-factor 28BS2692-2:1956 ii BSI 02-2000 Page Appendix F Measurement of recovery-voltage 29 Appendix G Example of
15、data to be included in a report of type-tests for breaking-capacity 29 Appendix H Insulation co-ordination 30 Appendix J Correction factors for atmospheric conditions during impulse-voltage tests, and for air density during wet withstand voltage tests 31 Appendix K Virtual time 31 Figure 1 Test-circ
16、uits and voltages 34 Figure 2 Test for current-limiting fuses 35 Figure 3 Determination of recovery-voltage 36 Figure 4 Prospective current oscillogram 37 Figure 5 Oscillogram for large prospective current 37 Figure 6 Examples of discrimination 38 Figure 7 Oscillogram for computation of power factor
17、 39 Figure 8 Air-density correction-factor 40 Figure 9 Correction-factor for humidity 41 Figure 10 Virtual time curves 42 Figure 11 Determination of virtual time 43 Figure 12 Dimensions for reference TA1 fuse-links. Voltage3.3kV.For use in air 44 Figure 13 Dimensions for reference TA2 fuse-links. Vo
18、ltage3.3kV.For use in air 45 Figure 14 Dimensions for Reference TA3 fuse-links. Voltage6.6/11kV.For use in air 46 Figure 15 Dimensions of Ferrule-type fuse links for use in air or oil 47 Table 1 Current-ratings for fuses other than voltage-transformer fuses 7 Table 2 Current-ratings for fuses primar
19、ily used for the protection of voltage-transformers 7 Table 3 Standard3-phase breaking-capacity ratings for fusesother than voltage-transformer fuses 8 Table 4 Standard3-phase breaking-capacity ratings forvoltage-transformer fuses 9 Table 5 Temporary test-connections for temperature-rise test 14 Tab
20、le 6 Power-frequency test-voltages for wet test on outdoor fuses 15 Table 7 Impulse-voltage tests for electrically exposed fuses 16 Table 8 Voltage settings in peakkV and r.m.s. kV of sphere-gapfor checking transient voltage of fuse operation 20 Table 9 Test-voltages in tests of longer duration than
21、 one minute 22 Table 10 25BS2692-2:1956 BSI 02-2000 iii Foreword This standard makes reference to the following BritishStandards: BS116, Oil circuit-breakers for alternating current systems. BS148, Insulating oil (low viscosity type) for transformers and switchgear. BS923, Impulse-voltage testing. B
22、S2782, Methods of testing plastics. This BritishStandard has been prepared to meet the need for a standard for fuses for a.c. circuits above1000volts, which is the upper limit of voltage for fuses covered by BS88. It is expected that additions to the standard will become necessary as knowledge incre
23、ases and, in particular, it is hoped to standardize dimensions to some extent when adequate experience has been gained with fuses in accordance with this standard. Some time must necessarily elapse before every such fuse can be supplied and certified to comply with the standard in all respects; in t
24、he meantime therefore its application should be subject to agreement between the contracting parties. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standar
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS269221956FUSESFORVOLTAGESEXCEEDING1000VACEXPULSIONFUSES1000V 以上 交流电 熔断器 部分 冲出 式熔丝 PDF

链接地址:http://www.mydoc123.com/p-543211.html