ASTM G122-1996(2015)e1 Standard Test Method for Evaluating the Effectiveness of Cleaning Agents《评定清洁剂有效性的标准试验方法》.pdf
《ASTM G122-1996(2015)e1 Standard Test Method for Evaluating the Effectiveness of Cleaning Agents《评定清洁剂有效性的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM G122-1996(2015)e1 Standard Test Method for Evaluating the Effectiveness of Cleaning Agents《评定清洁剂有效性的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: G122 96 (Reapproved 2015)1Standard Test Method forEvaluating the Effectiveness of Cleaning Agents1This standard is issued under the fixed designation G122; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of la
2、st revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEEditorial correction made in October 2015.INTRODUCTIONMany systems require a high degree of cleanliness. For example, gaseous a
3、nd liquid oxygensystems must be clean, particularly of hydrocarbons, to avoid the potential hazard of a reaction andsubsequent fire or explosion. Typically, chlorinated solvents have been used to clean systems andequipment that must be free of hydrocarbons and other contaminants. Environmental conce
4、rns dictatethat suitable replacements are needed. This test method presents a procedure that may be used toevaluate candidate aqueous or non aqueous cleaning agents.1. Scope1.1 This test method covers a procedure for evaluating thecapability of cleaning agents and processes to remove contami-nation
5、to the desired level.1.2 The test coupons provide a relatively rough surface towhich contamination can easily adhere.1.3 The capability of a particular cleaning agent dependsupon the method by which it is used and the characteristics ofthe article being cleaned, such as size, shape, and material.Fin
6、al evaluation of the cleaning agent should include testing ofactual products and production process.1.4 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.5 This standard does not purport to address all of thesafety concerns, if
7、 any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Specific precau-tionary statements are given in Note 2.2. Referenced Documents2.1 ASTM St
8、andards:2D1193 Specification for Reagent WaterE177 Practice for Use of the Terms Precision and Bias inASTM Test MethodsE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test MethodG94 Guide for Evaluating Metals for Oxygen ServiceG121 Practice for Preparation of Co
9、ntaminated Test Cou-pons for the Evaluation of Cleaning Agents2.2 ANSI Standard:3D46.1 Surface Texture (Surface Roughness, Waviness, Lay)3. Terminology3.1 Definitions:3.1.1 cleaning effectiveness factor (CEF), nthe fraction ofcontaminant removed from an initially contaminated testcoupon and determin
10、ed by gravimetric techniques.3.1.2 residual contamination, Rc,nthe absolute mass ofcontaminant remaining after the cleaning process and ex-pressed in milligrams per square centimetre of area or option-ally as milligrams per square foot.3.1.3 surface roughness, RA,nthe arithmetic average de-viation o
11、f the surface profile from the centerline, normallyreported in micrometres.1This test method is under the jurisdiction of ASTM Committee G04 onCompatibility and Sensitivity of Materials in Oxygen Enriched Atmospheres and isthe direct responsibility of Subcommittee G04.01 on Test Methods.Current edit
12、ion approved Oct. 1, 2015. Published October 2015. Originallyapproved in 1993. Last previous edition approved in 2008 as G122 96 (2008).DOI: 10.1520/G0122-96R15E01.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Boo
13、k of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West
14、 Conshohocken, PA 19428-2959. United States14. Summary of Test Method4.1 This test method provides quantitative results as to theability of a specific cleaning agent/process for removingselected contaminants from standard coupons. The couponsused for testing are prepared in accordance with Practice
15、G121.Cleaning is performed using a cleaning tank with or withoutultrasonic agitation, elevated temperature or other cleaningenhancement features and depends on the manufacturersinstructions. The effectiveness of the cleaning process isrepresented as CEF, the cleaning effectiveness factor, that is th
16、efraction of the contaminant removed as determined by gravi-metric techniques. A control coupon is used to account for anycorrosion or material removal effects due to the cleaningagent/process.5. Significance and Use5.1 The purpose of this test method is to define a procedurefor evaluating the capab
17、ility of cleaning agents to cleanmetallic coupons. Based on the outcome of the testing, suitablecleaning agents may be selected for cleaning in general and foroxygen service in particular.5.2 The cleaning parameters can be changed and the testmethod can be repeated. The usual cleaning parameters inc
18、ludecleaning agent concentration, temperature, and time; type andstrength of ultrasonic energy or agitation, if used, and others.NOTE 1Usual cleaning parameters are based on the manufacturersrecommendations.6. Apparatus6.1 Materials:6.1.1 Test Coupon, prepared in accordance with PracticeG121. The ma
19、ss of the coupon is approximately 30 to 45 g butwill vary significantly for each selected material. Typicalmaterials used in oxygen systems are described in Guide G94.6.1.2 Control CouponThis is uncontaminated and is sub-jected to the identical cleaning procedure as the contaminatedcoupons and serve
20、s to evaluate corrosion anderosion of the testcoupons.6.1.3 Cleaning Agent, prepared according to the manufac-turers instructions. Specification D1193 Type II water shall beused for preparing aqueous solutions.6.2 Equipment:6.2.1 Cleaning Tank, A vessel of sufficient size to conduct anumber of evalu
21、ations simultaneously. Testing is enhanced byhaving automatic temperature and time controls. A cleaningtank with ultrasonics may be used.6.2.2 Balance, accuracy to 0.1 mg. However, 0.01 mgaccuracy is desirable to detect contamination levels of 10mg/m2(1 mg/ft2) or less.6.2.3 Beaker HolderA device to
22、 support beakers in theultrasonic cleaner tank such that the beakers do not contact thebottom and sides of the tank.7. Test Procedure7.1 Prepare a minimum of six test coupons by PracticeG121.7.2 Indicate the masses of coupons in grams as MXy whereX is the coupon designation (number, letter, or name)
23、 and y =1indicates a clean coupon, y = 2 indicates a contaminatedcoupon and y = 3 indicates a coupon after cleaning.7.3 Designate one coupon as the control coupon to undergocleaning without contamination.7.4 Measure the mass of the control and test coupons(recording them as MX1 as previously defined
24、).7.5 Contaminate five test coupons in accordance with Prac-tice G121.7.6 Measure the mass of all contaminated test coupons(recording them as MX2 as previously defined).7.7 Process the control coupon in the test cleaning solutionseparately from the contaminated test coupons.7.8 The contaminated test
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMG12219962015E1STANDARDTESTMETHODFOREVALUATINGTHEEFFECTIVENESSOFCLEANINGAGENTS 评定 清洁剂 有效性 标准 试验 方法

链接地址:http://www.mydoc123.com/p-540312.html