《ASTM F2678-2010 Standard Practice for Preparing Panel Underlayments Thick Poured Gypsum Concrete Underlayments Thick Poured Lightweight Cellular Concrete Underlayments and Concretet.pdf》由会员分享,可在线阅读,更多相关《ASTM F2678-2010 Standard Practice for Preparing Panel Underlayments Thick Poured Gypsum Concrete Underlayments Thick Poured Lightweight Cellular Concrete Underlayments and Concretet.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F2678 10Standard Practice forPreparing Panel Underlayments, Thick Poured GypsumConcrete Underlayments, Thick Poured Lightweight CellularConcrete Underlayments, and Concrete Subfloors withUnderlayment Patching Compounds to Receive ResilientFlooring1This standard is issued under the fixed
2、 designation F2678; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revi
3、sion or reapproval.1. Scope1.1 This practice includes recommendations for preparingand smoothing panel underlayments, gypsum concrete andconcrete subfloors with patching compounds upon whichresilient flooring may be installed.1.2 This practice does not cover the adequacy of thesubfloor assembly to p
4、erform its structural requirements, whichis governed by local building codes.1.3 This practice does not supersede in any manner theresilient flooring, underlayment or adhesive manufacturerswritten instructions. Consult the individual resilient flooring,underlayment or adhesive manufacturer for speci
5、fic recom-mendations.1.4 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.5 This standard does not purport to address all of thesafety c
6、oncerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C109/C109M Test Method for Compressi
7、ve Strength ofHydraulic Cement Mortars (Using 2-in. or 50-mm CubeSpecimens)C472 Test Methods for Physical Testing of Gypsum, Gyp-sum Plasters and Gypsum ConcreteF141 Terminology Relating to Resilient Floor CoveringsF710 Practice for Preparing Concrete Floors to ReceiveResilient FlooringF1482 Practic
8、e for Installation and Preparation of PanelType Underlayments to Receive Resilient FlooringF2419 Practice for Installation of Thick Poured GypsumConcrete Underlayments and Preparation of the Surface toReceive Resilient FlooringF2471 Practice for Installation of Thick Poured LightweightCellular Concr
9、ete Underlayments and Preparation of theSurface to Receive Resilient Flooring3. Terminology3.1 Definitions used in this practice shall be in accordancewith Terminology F141.4. Significance and Use4.1 This practice provides minimum recommendations forpreparing and smoothing panel underlayments, thick
10、 pouredgypsum concrete underlayments, thick poured lightweightcellular concrete underlayments and concrete subfloors withpatching compounds. Actual requirements for materials to beused, mixtures, and other details are generally included as partof the project plans or specification details and may va
11、ry fromthe minimum recommendations set forth in this practice.5. Product Requirements5.1 The patching compound shall be able to be applied fromfeatheredge up to the manufacturers specified thickness overlarge areas.5.2 The patching compound may require the addition of anadditive other than water.1Th
12、is practice is under the jurisdiction of ASTM Committee F06 on ResilientFloor Coverings and is the direct responsibility of Subcommittee F06.40 onPractices.Current edition approved June 1, 2010. Published August 2010. DOI: 10.1520/F267810.2For referenced ASTM standards, visit the ASTM website, www.a
13、stm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.3 The
14、 patching compound shall be able to be covered byresilient floorings as soon as the patching hardens and driessufficiently.5.4 The dried patching compound shall be moisture-free,mildew-resistant and alkali-resistant.5.5 For commercial installations, the patching compoundshall develop a minimum of 30
15、00 psi compressive strengthafter 28 days when tested in accordance with Test MethodC109/C109M (air-cured only) or with Test Methods C472.6. Material Acceptance6.1 All patching compounds shall be delivered in theiroriginal, factory packaging.7. Material Storage, Conditioning and Protection7.1 All pat
16、ching compounds shall be kept dry in a tempera-ture controlled environment on site and protected from theweather at least 48 h prior to use. The temperature shall not bebelow 65F (18C) or above 100F (38C). Refer to thepatching compound manufacturers recommendation for morespecific instruction.7.2 Al
17、l patching compounds shall be kept off the ground andaway from damp and cold surfaces.7.3 Protect the applied patching compound from excessiveheat and drafty conditions while curing.7.4 Protect the applied patching compound and the entiresubfloor from traffic, dirt or dust or other contaminates such
18、 assweeping compounds until final installation of the resilientfloor covering.8. General Guidelines8.1 General Specifications:8.1.1 The patching compound shall not be applied to asubfloor containing frost. The subfloor surface temperatureshall not be below 50F (10C) or above 95F (35C). Thetemperatur
19、e conditions for installing resilient flooring productsand the patching compound is typically 65 to 85F (18 to 30C)for 48 h before, during and after the installation. The completeinstallation shall remain within the range of 55 to 95F (13 to35C) thereafter.8.1.2 All subfloors shall be clean and free
20、 of dust, oil,grease, paint, tar, wax, curing compounds, sealers, from releaseagents, primers, free alkali, loosely bonded toppings, looseparticles, old adhesive residues and any other substance thatmay prevent or reduce adhesion of the patching compound.8.1.3 Any substance that may reduce or preven
21、t the adhe-sion from the subfloor shall be completely removed bymechanical means only. Refer to supplementary requirementsection.8.1.4 Structural lightweight concretes having a minimumdensity of 115 lb/ft3(1842 kg/m3) and a minimum compressivestrength of 3000 psi can be suitable substrates to receiv
22、epatching compounds.8.1.5 The temperature of a heated subfloor must not exceed85F (30C).8.1.6 All moving joints such as expansion joints, isolationjoints and any cracks exhibiting movement shall not be filledwith patching compound or covered with resilient flooring.Consult the resilient flooring man
23、ufacturer regarding the use ofan expansion joint covering system.8.2 Panel Underlayment:8.2.1 All panel underlayment used shall be recommendedby either the panel underlayment manufacturer or the resilientflooring manufacturer.8.2.2 All panel underlayment shall be installed in accor-dance with the St
24、andard Practice F1482.8.2.3 All wood structural panel floor assemblies shall bedouble-layered. The subfloor panel shall be58 in. (16 mm)thick minimum wood structural panels (usually Exterior GradePlywood) over joist 16 in. (41 cm), typically on center. Joistcenter spacing shall comply with local bui
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF26782010STANDARDPRACTICEFORPREPARINGPANELUNDERLAYMENTSTHICKPOUREDGYPSUMCONCRETEUNDERLAYMENTSTHICKPOUREDLIGHTWEIGHTCELLULARCONCRETEUNDERLAYMENTSANDCONCRETETPDF

链接地址:http://www.mydoc123.com/p-539249.html