《ASTM F2567-2006 Standard Practice for Testing for Classical Pathway Complement Activation in Serum by Solid Materials《用固体材料在血清中进行补充激活试验的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM F2567-2006 Standard Practice for Testing for Classical Pathway Complement Activation in Serum by Solid Materials《用固体材料在血清中进行补充激活试验的标准实施规程》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 2567 06Standard Practice forTesting for Classical Pathway Complement Activation inSerum by Solid Materials1This standard is issued under the fixed designation F 2567; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, t
2、he year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice provides a protocol for rapid, in vitrofunctional screening for classical pathway complement
3、 activat-ing properties of solid materials used in the fabrication ofmedical devices that will contact blood.1.2 This practice is intended to evaluate the acute in vitroclassical pathway complement activating properties of solidmaterials intended for use in contact with blood. For thispractice, “ser
4、um” is synonymous with “complement.”1.3 This practice consists of two procedural parts. Proce-dureAdescribes exposure of solid materials to a standard lot ofhuman serum HS, using 0.1 mL serum per 133100 mmdisposable glass test tube. Procedure B describes assaying theexposed serum for significant fun
5、ctional classical pathwaycomplement depletion (decrease in amount of C4) as comparedto control serum samples not exposed to the material. Theendpoint in Procedure B is lysis of sheep red blood cells (RBC)coated with antibody (hemolysin).1.4 This practice does not address the use of plasma as asource
6、 of complement.1.5 This practice is one of several developed for theassessment of the biocompatibility of materials. Practice F 748may provide guidance for the selection of appropriate methodsfor testing materials for other aspects of biocompatibility.Practice F 1984 provides guidance for testing so
7、lid materialsfor whole complement activation in human serum, but does notdiscriminate between the classical or alternative pathway ofactivation. Practice F 2065 provides guidance for testing solidmaterials for alternative pathway complement activation inserum.1.6 This standard does not purport to ad
8、dress all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2F 748 Practi
9、ce for Selecting Generic Biological Test Meth-ods for Materials and DevicesF 1984 Practice for Testing for Whole Complement Activa-tion in Serum by Solid MaterialsF 2065 Practice for Testing for Alternative PathwayComplement Activation in Serum by Solid Materials2.2 Other Document:ISO 10993-4 Biolog
10、ical Evaluation of Medical Devices,Part 4: Selection of Tests for Interactions with Blood33. Terminology3.1 Definition of Term Specific to This Standard:3.1.1 waterdistilled, endotoxin-free.3.2 Abbreviations:3.2.1 Abantibody (hemolysin)3.2.2 BBSbarbital buffered saline3.2.3 BBS-Gbarbital buffered sa
11、linegelatin3.2.4 BBS-GM (Ca Buffer)barbital buffered salinegelatinmetals3.2.5 C8complement3.2.6 C4the fourth component of complement3.2.7 C4(-)GPSC4-deficient guinea pig serum serumfrom guinea pigs genetically incapable of producing C43.2.8 EDTAethylenediaminetetraacetic acid, disodiumsalt, dihydrat
12、e3.2.9 HAGGheat aggregated gamma globulin3.2.10 HShuman serum3.2.11 I“ice” control tube with serum but no material,kept on ice3.2.12 Mtube containing serum plus a test material3.2.13 NMtube containing serum but no material1This practice is under the jurisdiction ofASTM Committee F04 on Medical andSu
13、rgical Materials and Devices and is the direct responsibility of SubcommitteeF04.16 on Biocompatibility Test Methods.Current edition approved Oct. 1, 2006. Published October 2006.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org.
14、 For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.1Copyright ASTM International, 100 Barr Harbor Drive, P
15、O Box C700, West Conshohocken, PA 19428-2959, United States.3.2.14 RBCred blood cell(s)4. Summary of Practice4.1 This practice is based on a method published by Gaitheret al, 1974 (1).44.2 Solid material specimens are exposed to a standard lotof human C8 (specially-prepared, commercial human serumHS
16、) under defined conditions, in parallel with appropriatecontrols (Procedure A). If the classical complement pathway isactivated by the material, C4 will be depleted from the serum.Exposed serum is then tested for remaining C4 functionalactivity. An appropriate dilution of the HS, which by itself ist
17、oo dilute to lyse sensitized sheep RBC, is added to hemolysin-coated sheep RBC in the presence of C4(-)GPS in which allcomplement components save the missing C4 are present inexcess (Procedure B). Hemolysis in Procedure B provides aquantitative measure of the C4 remaining in HS exposed to testmateri
18、al in Procedure A. Depletion of hemolysis indicatesspecific classical pathway activation in the human serumcaused by exposure to the test material.5. Significance and Use5.1 Inappropriate activation of complement by blood-contacting medical devices may have serious acute or chroniceffects on the hos
19、t. Solid medical device materials may activatecomplement directly by the alternative pathway, or indirectlybecause of antigen-bound antibodies (as with immuno-adsorption columns) by the classical pathway. This practice isuseful as a simple, inexpensive, function-based screeningmethod for determining
20、 complement activation by solid mate-rials in vitro by the classical pathway.5.2 This practice is composed of two parts. In part A(Section 11), HS is exposed to a solid material. If complementactivation occurs by the classical pathway, C4 will be depleted.Activation by the alternative pathway will n
21、ot deplete C4. Inpart B (Section 12), C4 activity remaining in the serum afterexposure to the test material is assayed by diluting the serumbelow the concentration needed to lyse antibody-coated sheepRBC on its own, then adding the diluted HS to C4(-)GPS(which is itself at a dilution where all compl
22、ement componentsare in excess save the missing C4). Lacking C4, the C4(-)GPSdoes not lyse the antibody-coated sheep RBC unless C4 ispresent in the added HS. The proportion of lysis remaining inthe material-exposed HS sample versus the 37C control HSsample (which was not exposed to the test material)
23、 indicatesthe amount of C4 present in the HS, loss of which correlateswith classical pathway activation.5.3 This function-based in vitro test method for classicalpathway complement activation is suitable for adoption inspecifications and standards for screening solid materials foruse in the construc
24、tion of medical devices intended to beimplanted in the human body or placed in contact with humanblood outside the body. It is designed to be used in conjunctionwith Practice F 1984 for function-based whole complementactivation screening, and Practice F 2065 for function-basedalternative pathway act
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF25672006STANDARDPRACTICEFORTESTINGFORCLASSICALPATHWAYCOMPLEMENTACTIVATIONINSERUMBYSOLIDMATERIALS

链接地址:http://www.mydoc123.com/p-538997.html