1、Designation: F 2321 05Standard Specification forFlexible Insulated Temporary By-Pass Jumpers1This standard is issued under the fixed designation F 2321; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A n
2、umber in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 These specifications cover the manufacture and testingof flexible insulated temporary bypass jumpers (bypass jump-ers) used on energize
3、d power lines and equipment.1.2 It is common practice for the user of this protectiveequipment to prepare complete instructions and safety regula-tions to govern in detail the correct and safe use of suchequipment. Also see 4.2.1.3 The use and maintenance of this equipment are beyondthe scope of the
4、se specifications.1.4 These specifications for a system of bypass jumpers iscovered in four parts as follows:Title SectionsClamps for Bypass Jumpers 5-17Ferrules for Bypass Jumpers 18-31Cable for Bypass Jumpers 32-40Bypass Jumpers (complete assemblywith clamps, ferrules, and cable)41-551.5 Each of t
5、he four parts is an entity of itself, but is listedas a part of the system for completeness and clarification.1.6 The values stated in SI units are to be regarded as thestandard. See ASTM SI 10.1.7 The following precautionary caveat pertains only to thetest method portions, Sections 13, 26, 48, and
6、55 of thesespecifications. This standard does not purport to address all ofthe safety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory requirements prio
7、r to use.2. Referenced Documents2.1 ASTM Standards:2B33 Specification for Tinned Soft Annealed Copper Wirefor Electrical PurposesB 172 Specification for Rope-Lay-Stranded Copper Con-ductors Having Bunch-Stranded Members, for ElectricConductorsB 173 Specification for Rope-Lay-Stranded Copper Con-duct
8、ors Having Concentric-Stranded Members, for Elec-trical ConductorsD 2768 Specification for General-Purpose Ethylene-Propylene Rubber Jacket for Wire and CableD 2770 Specification for Ozone-Resisting Ethylene-Propylene Rubber Integral Insulation and Jacket for Wireand CableD 2802 Specification for Oz
9、one-Resistant Ehtylene-AlkenePolymer Insulation for Wire and CableD 2865 Practice for Calibration of Standards and Equip-ment for Electrical Insulating Materials TestingE8 Test Methods for Tension Testing of Metallic MaterialsF 819 Terminology Relating to Electrical Protective Equip-ment for Workers
10、SI 10 Practice for Use of the International System of Units(SI) (the Modernized Metric System)2.2 ANSI Standard:3ANSI C39.5 Safety Requirements for Electrical and Elec-tronic Measuring and Controlling InstrumentsANSI C84.1 Voltage Ratings for Electric Power Systemsand Equipment (60 Hz)ANSI C119.4 Am
11、erican National Standard for ElectricalConnectors2.3 NEMA Standard:4WC 8 Ethylene-Propylene-Rubber Insulated Wire andCable for the Transmission and Distribution of ElectricalEnergy (formerly ICEA S-68-516)3. Terminology3.1 Definitions:3.1.1 flexible insulated temporary bypass jumpersdevicesdesigned
12、and used to keep electric supply circuits effectivelycontinuous (electrically bridged) for short periods of time at1This specification is under the jurisdiction of ASTM Committee F18 onElectrical Protective Equipment for Workers and is the direct responsibility ofSubcommittee F18.45 on Mechanical Eq
13、uipment.Current edition approved April 1, 2005. Published May 2005. Originallyapproved in 2003. Last previous edition approved in 2003 as F 232103.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandard
14、s volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036.4Available from National Electrical Manufacturers Association (NEMA), 1300N. 17th St., Suite 1847, Rosslyn,
15、 VA 22209.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.work locations when conductors or equipment may otherwisebe opened or made electrically discontinuous during workoperations.3.1.1.1 DiscussionThe devices are normally installe
16、d,used, and removed as part of a protective insulating systemcomposed of insulating covers and/or observances of requiredminimum safe approach distances for workers.3.1.2 voltage, normal designa nominal value consistentwith the latest revision of ANSI C84.1, assigned to the circuitor system for the
17、purpose of conveniently designating itsvoltage class.3.1.3 voltage, maximum usethe ac voltage (rms) classifi-cation of the protective equipment that designates the maxi-mum nominal design voltage of the energized system that maybe safely worked. The nominal design voltage is equal tophase-to-phase v
18、oltage on multiphase circuits.3.1.3.1 DiscussionIf there is no multiphase exposure in asystem area, and the voltage exposure is limited to phase(polarity on dc systems) to ground potential, the phase (polarityon dc systems) to ground potential shall be considered to be thenominal design voltage.3.1.
19、3.2 DiscussionIf electrical equipment and devices areinsulated or isolated, or both, such that the multiphase exposureon a grounded wye circuit is removed, then the nominal designvoltage may be considered as the phase-to-ground voltage onthat circuit.NOTE 1The work practices and methods associated w
20、ith removingmultiphase exposures at any given work site are not addressed in thisspecification.3.2 For definitions of other terms, refer to TerminologyF 819.4. Significance and Use4.1 These specifications cover the minimum electrical andphysical properties designated by the manufacturer and thedetai
21、led procedures by which such properties are to be deter-mined. The purchaser may at his option perform or haveperformed any of these tests in order to verify the manufactur-ers designation. Claims for failure to meet the specification aresubject to verification by the manufacturer.4.2 Bypass jumpers
22、 are devices designed and used to keepelectrical circuits effectively continuous (electrically bridged)for short periods of time at work locations when conductors orequipment may otherwise be opened or made discontinuousduring work operations. Bypass jumpers are insulated totemporarily protect perso
23、nnel from brush or accidental contactonly; therefore, when authorizing their use, a margin of safetyshould be provided between the maximum voltage used on,and the proof-test voltage at which they are tested. Therelationship between proof-test voltage and the maximumvoltage at which bypass jumpers ar
24、e used is shown in Table 1.WarningPortions of these devices (clamps and ferrules) arenot insulated and offer no protection from accidental contact.CLAMPS FOR BYPASS JUMPERS5. Scope5.1 This specification covers clamps used in the assembly ofbypass jumpers.6. Classification6.1 Clamps are furnished in,
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF23212005STANDARDSPECIFICATIONFORFLEXIBLEINSULATEDTEMPORARYBYPASSJUMPERS 柔性 绝缘 临时 旁路 跳线 标准规范 PDF

链接地址:http://www.mydoc123.com/p-538386.html