1、Designation: F2073 01 (Reapproved 2006)F2073 14Standard Test Method forNon-Destructive Short Circuit Testing of a MembraneSwitch1This standard is issued under the fixed designation F2073; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revis
2、ion, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This standard establishes a test method for detecting unwanted electrical shorts in a membrane switch
3、.1.2 Since this is a non-destructive test, it can be performed on a membrane switch that is going to be mounted and used in itsintended environment.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this s
4、tandard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.2. Terminology2.1 Definitions:2.1.1 shortunwanted electrical connection between two test points having a resistance lower than the specified open circuitresistance.2.1.2
5、 membrane switcha momentary switching device in which at least one contact is on, or made of, a flexible substrate.2.1.3 specified open circuit resistanceminimum allowable resistance as measured between two test points that, if lower than,will indicate an electrical short.2.1.4 test pointan electric
6、al input or outpoint connection on the membrane switch.3. Significance and Use3.1 Destructive and non-destructive tests characteristics must be evaluated to ensure the membrane switch will operate andsurvive the application it was designed for. It is not feasible for all tests to be performed on eac
7、h membrane of a production lot.However, there are some non-destructive tests that must be performed on each switch assembly to ensure 100 % functionality andchecking each i/o point for unwanted electrical continuity to any other i/o point is one of these characteristics.4. Apparatus4.1 Electrical Te
8、ster, capable of measuring the electrical resistance between two test points.4.1.1 Electrical Tester must be capable of detecting a short when a resistance is measured between any of the test points thatis less than an the specified open circuit resistance.4.1.2 Since this is a non-destructive test,
9、 the applied voltage should not exceed operating the specified voltage selectedappropriately.5. Procedure5.1 Pretest Setup:5.1.1 Connect test points of the switch assembly to the Electrical Tester.5.1.2 Adjust test voltage source as necesary.necessary.5.1.3 Adjust threshold resistance to the specifi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF20732014STANDARDTESTMETHODFORNONDESTRUCTIVESHORTCIRCUITTESTINGOFAMEMBRANESWITCH 薄膜开关 无损 短路 检验 标准

链接地址:http://www.mydoc123.com/p-536475.html