ASTM F2072-2014 Standard Test Method for Hosedown of a Membrane Switch《薄膜开关软管洗涤的标准试验方法》.pdf
《ASTM F2072-2014 Standard Test Method for Hosedown of a Membrane Switch《薄膜开关软管洗涤的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM F2072-2014 Standard Test Method for Hosedown of a Membrane Switch《薄膜开关软管洗涤的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F2072 01 (Reapproved 2007)F2072 14Standard Practice Test Method forHosedown of a Membrane Switch1This standard is issued under the fixed designation F2072; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of la
2、st revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice establishes procedures for the hosedown of a membrane switch to verify adequate protection from ingress of
3、water from a high-volume water spray.1.2 This practice can also be used to verify the ability of a membrane switch or graphics layer to act as a liquid seal for a finishedproduct.1.3 Additional test methods or practices can be incorporated to investigate specific results or capabilities.1.4 This pra
4、ctice is a modification of NEMA Publication Number 250-1991 Section 6.7 which is a test for hosedown of afinished product housing.2. Referenced Documents2.1 NEMA Publication 250-199123. Terminology3.1 Definitions:3.1.1 membrane switch, na momentary switching device in which at least one contact is o
5、n, or made of, a flexible substrate.3.1.2 specified resistance, nmaximum allowable resistance as measured between two terminations whose internal switchcontacts, when held closed, complete a circuit.4. Significance and Use4.1 The presence of water inside a membrane switch can affect its mechanical o
6、peration or electrical functionality, or both.4.2 This practice establishes a procedure to verify the ability of a membrane switch to resist the entry of liquid into itself or afinished product, or both. It is useful in identifying design deficiencies.4.3 Hosedown testing may be destructive, therefo
7、re any samples tested should be considered unfit for future use.5. Interferences5.1 External VentingAny deliberate external venting of the switch will allow liquid to enter.5.2 Atmospheric PressureSignificant changes in atmospheric pressure during the test or at different facilities may alter thetim
8、e in which leakage might occur.5.3 Duration of TestLonger exposure time increases the possibility of leakage.5.4 Dye ColoringChoose a dye coloring that will not chemically attack the materials.6. Apparatus6.1 Water Supply, capable of delivering a stream of water at a rate of at least 65 gal/min thro
9、ugh a 1 in. (25 mm) internaldiameter nozzle for the specified duration,6.2 An appropriate device or fixture to hold the switch in a fixed position,1 This practice test method is under the jurisdiction of ASTM Committee F01 on Electronics and is the direct responsibility of Subcommittee F01.18 on Mem
10、braneSwitches.Current edition approved Feb. 1, 2007Jan. 1, 2014. Published March 2007January 2014. Originally approved in 2000. Last previous edition approved in 20012007 asF2072F207201(2007).01. DOI: 10.1520/F2072-01R07.10.1520/F2072-14.2 For referencedASTM standards, visit theASTM website, www.ast
11、m.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what ch
12、anges have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the off
13、icial document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States16.3 Any additional equipment as required by other test methods employed, and6.4 Nozzle with 1 in. (25 mm) internal diameter.7. Test Specimen7.1 The test specimen will be a
14、 membrane switch with or without graphics laminated to a rigid material or the final intendedmounting configuration (using a clear material will facilitate visual inspection).8. Conditioning8.1 Condition specimens by exposure to ambient conditions for 72 h prior to hosedown to allow full cure of adh
15、esives.9. Procedure9.1 Pre-Test Setup:9.1.1 Fixture Unit Under Test (UUT) as specified.9.2 In-Process Test:9.2.1 Test switch for proper function if required.9.2.2 Direct water flow at test specimen at all angles of potential water entry such as seams, joints, external operatingmechanisms, etc. from
16、a distance of 10 to 12 ft (3.0 to 3.5 m) for a total of 5 min or as specified.9.2.3 Test switch for proper function if required.9.2.4 Perform visual inspection to determine if liquid has penetrated the UUT.10. Report10.1 Report the following information:10.1.1 Duration of test,10.1.2 Physical/Aesthe
17、tic changes, and10.1.3 Functional test data, if required.11. Keywords11.1 hose down; membrane switch; water sprayASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentionedin this standard. Users of this standard are expressly advi
18、sed that determination of the validity of any such patent rights, and the riskof infringement of such rights, are entirely their own responsibility.This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years andif not revised, either
19、reapproved or withdrawn.Your comments are invited either for revision of this standard or for additional standardsand should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of theresponsible technical committee, which you may attend. If
20、you feel that your comments have not received a fair hearing you shouldmake your views known to the ASTM Committee on Standards, at the address shown below.This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,United States. Individu
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF20722014STANDARDTESTMETHODFORHOSEDOWNOFAMEMBRANESWITCH 薄膜开关 软管 洗涤 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-536473.html