1、Designation: F 1895 98 (Reapproved 2004)Practice forSubmersion of a Membrane Switch1This standard is issued under the fixed designation F 1895; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in
2、parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice establishes procedures for the submergingof a membrane switch to verify resistance to ingress of aspecified liquid.1.2 This practi
3、ce can also be used to verify the ability of amembrane switch or graphics layer to act as a liquid seal for afinished product.1.3 Additional test methods or practices can be incorporatedto investigate specific results or capabilities.1.4 This practice is a modification of National ElectricalManufact
4、urers Assoc. (NEMA) Publication Number 250-1991Section 6.10, which is a test for submersion of a finishedproduct housing.1.5 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are forinformation only.2. Referenced Documents2.1 National Electrical
5、 Manufacturers Assoc.:NEMA Publication 250-199123. Terminology3.1 Definitions:3.1.1 membrane switchA momentary switching device inwhich at least one contact is on, or made of, a flexiblesubstrate.3.1.2 specified resistancemaximum allowable resistanceas measured between two terminations whose interna
6、l switchcontacts, when held closed, complete a circuit.3.1.3 silver migrationgrowth of fine crystals betweensilver conductors of a thick film circuit due to an ionic reactionto the presence of water and an applied dc voltage potential.4. Significance and Use4.1 The presence of water inside a membran
7、e switch canaffect its mechanical operation or electrical functionality, orboth. Electrical failure can result as short circuits due to silvermigration or exceeding the specified resistance due to oxida-tion.4.2 This practice establishes a procedure to verify the abilityof a membrane switch to resis
8、t the entry of liquid in itself or afinished product, or both. It is useful in identifying designdeficiencies.4.3 Submersion testing may be destructive, therefore anysamples tested should be considered unfit for future use.5. Interferences5.1 External Ventingany deliberate external venting of theswi
9、tch will allow liquid to enter.5.2 Atmospheric Pressuresignificant changes in atmo-spheric pressure during the test or at different facilities mayalter the time in which leakage might occur.5.3 Duration of Testlonger submersion time increases thepossibility of leakage.5.4 Dye Coloringchose a dye col
10、oring that will notchemical attack the materials.6. Apparatus6.1 Tub of sufficient size and depth (w/cover) for the entireswitch, including any mounting surface to be submerged by atleast 1 in. (25.4 mm) or as specified.6.2 An appropriate device of fixture to hold the switch in afixed position.6.3 A
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF189519982004PRACTICEFORSUBMERSIONOFAMEMBRANESWITCH 薄膜开关 浸没 操作规程 PDF

链接地址:http://www.mydoc123.com/p-535973.html