1、Designation: F1989 05 (Reapproved 2013)Standard Specification forCooking Fire Suppression Blankets1This standard is issued under the fixed designation F1989; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision
2、. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers requirements for cooking firesuppression blankets to extinguish accidental cooking fires.1.2 This specifi
3、cation does not apply to cooking fire sup-pression blankets that: are made from asbestos; have sides ofdiffering appearance, finish or color; have a performance thatdiffers according to which side is used; or, are of metallicconstruction or component.1.3 The values stated in SI units are to be regar
4、ded as thestandard.1.4 The following safety hazards caveat pertains only to thetest methods portion of this specification, Section 4: Thisstandard does not purport to address all of the safety concerns,if any, associated with its use. It is the responsibility of the userof this standard to establish
5、 appropriate safety and healthpractices and determine the applicability of regulatory limita-tions prior to use.2. Terminology2.1 Definitions For the purpose of this specification, thefollowing definition applies:2.1.1 fire blanket, nflexible sheet(s) of material intendedto be used to extinguish sma
6、ll fires by smothering.3. Physical Properties3.1 Size and ShapeCooking fire suppression blankets shallbe rectangular or square, with no edge less than 0.91 6 0.05 m(36 6 2 in.).3.2 MassCooking fire suppression blankets shall have amass not exceeding 2 kg (4.4 lb).3.3 Hand Holding Devices:3.3.1 Hand
7、holding devices, if provided, shall consist ofsewn in straps on both sides of the blanket to facilitate quickrelease. The strap length shall not be less than 100 mm (3.9 in.)or more than 200 mm (7.8 in.) in length, and easily grasped andreleased when applying the blanket over a cooking fire. Thestra
8、ps may be made of any high strength material and shall beof contrasting color from the blanket itself.3.3.2 Attention shall be paid to the design of any holdingdevice to ensure ease of handling and hand release.3.4 Appearance and Bi-Lateral UseThe two sides of a fireblanket shall be of identical app
9、earance, finish or color andshall give the equivalent results when tested for compliancewith Section 4.NOTE 1It is important not only that either side of fire blanket can beexposed to the fire or other hazard with equal effectiveness, but also thatno doubt be created in the mind of the user at the m
10、oment of emergencyuse as to which side of the fire blanket to apply to the hazard.3.5 Resistance to Fraying or TearingThe edges of cook-ing fire suppression blankets shall not fray or tear duringtesting for compliance with 4.3.1, 4.3.2, 4.4.4, and 4.5.1.5.4. Test Methods4.1 Sampling and Sequence of
11、Testing:4.1.1 A minimum of nine cooking fire suppression blanketsis required. Identify and mark the cooking fire suppressionblankets as No. 1 to 9 and the two sides as (a) and (b).4.1.1.1 Cooking fire suppression blankets which contain aseam shall be tested both on and off the seam and, where thesea
12、m is tested, in the most unfavorable condition. Tests shall becarried out using a single thickness of cooking fire suppressionblankets.4.1.2 Use any fire blanket as required for the nondestructiveexaminations required in Section 4. Use cooking fire suppres-sion blankets No. 1, 2, and 3 for testing t
13、o 4.5.1 in the sequenceof 1(a), 2(b), 3(a). Use cooking fire suppression blankets 4, 5and 6 for testing to 4.4 in sequence of 4(a), 5(b), and 6(a). Usecooking fire suppression blankets 7, 8 and 9 for testing to 4.5.2in sequence of 7(a), 8(b), and 9(a).4.2 Conditioning:4.2.1 Condition cooking fire su
14、ppression blankets for test-ing for 48 h so that they are in equilibrium with air at 20 6 5Cand at a relative humidity of 50 to 70 %. After conditioning, donot expose the blanket to air at different temperature or relativehumidity for longer than 5 min before testing. Keep the fireblanket in a seale
15、d plastic bag or other conditioning containeruntil testing if it is necessary to transport it any distance to thetest site.1This specification is under the jurisdiction of ASTM Committee F15 onConsumer Products and is the direct responsibility of Subcommittee F15.46 on FireSuppression Towels.Current
16、 edition approved April 1, 2013. Published August 2013. Originallyapproved in 1999. Last previous edition approved in 2005 as F1989 05. DOI:10.1520/F1989-05R13.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14.2.2 Store fire blanket f
17、or testing in their containers, or inthe recommended storage condition for 24 h immediately priorto the testing for conformity with the requirements of Section4.4.2.3 Except where otherwise specified, tests shall be car-ried out at 20 6 10C.4.3 General Tests:4.3.1 Flexibility TestBlankets shall be c
18、apable of beingrolled without permanent deformation along any axis com-pletely around a 50-mm diameter bar.4.3.2 Ease of Removal TestCooking fire suppression blan-kets shall be designed and located in such a way that the usercan remove, unfold, and make ready for use in not more than4 s. The force r
19、equired to remove the fire blanket from itscontainer (if used) shall not exceed 80 N.4.4 Electrical Resistance Test:4.4.1 PrincipleThe electrical resistance of the fire blanketis measured between a negative electrode formed by a steel oraluminum-topped table and a flat rectangular conducting posi-ti
20、ve electrode.4.4.2 Apparatus:4.4.2.1 Table, with a steel or aluminum top.4.4.2.2 Megohmeter, 500 V, dc.4.4.2.3 Flat Rectangular Conducting Positive Electrode,450 by 150 mm, total mass of 5 kg (including metal base,backing support and insulating handle (see Fig. 1).4.4.3 ProcedureArrange the apparatu
21、s as shown in Fig. 1.Lay the fire blanket flat on the table and zero and operate themegohmeter in accordance with the manufacturers instruc-tions. Move the instrument and the fire blanket as necessary,then check the whole surface area of the blanket. Test threecooking fire suppression blankets.4.4.4
22、 Interpretation of ResultsA fire blanket is consideredto be in conformance with this specification if the electricalresistance of the fire blanket is not less than 1 M at any point.4.5 Fire Performance Tests:4.5.1 Volatile Liquid Test Fires:4.5.1.1 FuelThe fuel shall be an aliphatic hydrocarbon ofin
23、itial boiling point not less than 88C and final boiling pointnot more than 105C. It is not necessary to use fresh fuel foreach test provided that the initial fuel temperature is 20 6 5C.4.5.1.2 Tray Dimensions and Quantity of FuelThe dimen-sions of the welded 2-mm sheet steel circular cylindrical tr
24、aysare given in Table 1.4.5.1.3 SitingPosition the test tray on a 0.8-m high hori-zontal metal table, not smaller than the fire blanket to be testedand between 1.45 and 1.8 m square, equidistant from twoopposite sides and so that the distance from one of the othertwo sides (Side (a) to the far edge
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF198920052013STANDARDSPECIFICATIONFORCOOKINGFIRESUPPRESSIONBLANKETS 烹饪 灭火 标准规范 PDF

链接地址:http://www.mydoc123.com/p-536236.html