《ASTM F1812-2015 Standard Test Method for Determining the Effect of an ESD Discharge on a Membrane Switch or Printed Electronic Device《测定薄膜开关或印刷电子设备ESD放电效果的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM F1812-2015 Standard Test Method for Determining the Effect of an ESD Discharge on a Membrane Switch or Printed Electronic Device《测定薄膜开关或印刷电子设备ESD放电效果的标准试验方法》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F1812 15Standard Test Method forDetermining the Effect of an ESD Discharge on a MembraneSwitch or Printed Electronic Device1This standard is issued under the fixed designation F1812; the number immediately following the designation indicates the year oforiginal adoption or, in the case
2、of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method is used to determine the electrostaticdischarge (ESD) shielding effectivenes
3、s of a membrane switchassembly or printed electronic device. This test method may beused to test a membrane switch or printed electronic device todestruction, that is, to determine its maximum ESD shieldingeffectiveness, or it may be used to test the ability of amembrane switch or printed electronic
4、 device to withstand apredetermined level of exposure.1.2 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is therespon
5、sibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use2. Terminology2.1 Definitions:2.1.1 discharge pulse countnumber of applied discharges.2.1.2 discharge pulse intervaltime duration between
6、 ap-plied voltage.2.1.3 ESD (electrostatic discharge) eventdetection of ap-plied charge at input/output (I/O) points.2.1.4 I/O pointsspecified conductive area, location, orcircuitry, typically all circuit paths, traces and wires.3. Significance and Use3.1 Nearly all electronic devices are susceptibl
7、e to possibledamage or degradation from ESD encountered in their operat-ing environments. The sensitivity of the equipment, the poten-tial consequences of a malfunction, and the expected environ-mental conditions all impact the level of ESD protectionneeded.3.2 ESD shielding effectiveness test may b
8、e destructive, andunits that have been tested should be considered unreliable forfuture use.4. Interferences4.1 The following parameters may affect the results of thistest:4.1.1 Temperature may affect the tendency of an ESD eventto occur,4.1.2 Relative humidity may affect the tendency of an ESDevent
9、 to occur,4.1.3 Barometric pressure may affect the tendency of anESD event to occur, and4.1.4 The composition of the work bench may influence thetest results.5. Apparatus5.1 Discharge Probe.5.2 ESD SimulatorCommercially available device for ap-plying required or specified voltages, monitoring for ES
10、Devent and selecting various voltage levels, and probes forcontact or air discharge.6. Procedure: Direct Application of Discharge6.1 Pretest Setup:6.1.1 Place switch on a nonconductive surface, or as speci-fied.6.1.2 If applicable, connect the ESD shield, ground trace, orground plane to earth ground
11、.6.1.3 Connect all circuitry pin inputs or outputs to the ESDgenerating devices ground.6.1.4 Ambient laboratory conditions to be within:6.1.4.1 Relative humidity 30 to 60 %,6.1.4.2 Temperature 15 to 35C, and6.1.4.3 Atmospheric pressure 680 to 1060 mbar or other-wise specified.6.2 In Process:6.2.1 Ac
12、cumulation of charge on the membrane switch orprinted electronic device must be dissipated between succes-sive tests.6.2.2 Set the initial voltage level to 2Kv. Set discharge pulseinterval as specified.1This test method is under the jurisdiction of ASTM Committee F01 onElectronics and is the direct
13、responsibility of Subcommittee F01.18 on PrintedElectronics.Current edition approved June 1, 2015. Published July 2015. Originally approvedin 1997. Last previous edition approved in 2009 as F1812-09. DOI: 10.1520/F1812-15.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshoh
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF18122015STANDARDTESTMETHODFORDETERMININGTHEEFFECTOFANESDDISCHARGEONAMEMBRANESWITCHORPRINTEDELECTRONICDEVICE

链接地址:http://www.mydoc123.com/p-535736.html