ASTM E963-1995(2004) Standard Practice for Electrolytic Extraction of Phases from Ni and Ni-Fe Base Superalloys Using a Hydrochloric-Methanol Electrolyte《用盐酸甲烷电解质从镍和镍铁积超热合金中进行相位的电解.pdf
《ASTM E963-1995(2004) Standard Practice for Electrolytic Extraction of Phases from Ni and Ni-Fe Base Superalloys Using a Hydrochloric-Methanol Electrolyte《用盐酸甲烷电解质从镍和镍铁积超热合金中进行相位的电解.pdf》由会员分享,可在线阅读,更多相关《ASTM E963-1995(2004) Standard Practice for Electrolytic Extraction of Phases from Ni and Ni-Fe Base Superalloys Using a Hydrochloric-Methanol Electrolyte《用盐酸甲烷电解质从镍和镍铁积超热合金中进行相位的电解.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 963 95 (Reapproved 2004)Standard Practice forElectrolytic Extraction of Phases from Ni and Ni-Fe BaseSuperalloys Using a Hydrochloric-Methanol Electrolyte1This standard is issued under the fixed designation E 963; the number immediately following the designation indicates the year ofo
2、riginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers a procedure for the isolation ofcarbid
3、es, borides, TCP (topologically close-packed), and GCP(geometrically close-packed) phases (Note 1) in nickel andnickel-iron base gamma prime strengthened alloys. Contami-nation of the extracted residue by coarse matrix (gamma) orgamma prime particles, or both, reflects the condition of thealloy rath
4、er than the techniques mentioned in this procedure.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of
5、regulatory limitations prior to use. (See 3.3.2.1 and4.1.1.)NOTE 1Ni3Ti (eta phase) has been found to be soluble in theelectrolyte for some alloys.2. Terminology2.1 Definitions:2.1.1 extraction celllaboratory apparatus consisting of abeaker to contain the electrolyte, a dc power supply, a noblemetal
6、 sheet or screen cathode and a noble metal wire basket orwire to affix to the sample (anode).2.1.2 geometrically close-packed (GCP) phasesprecipitated phases found in nickel-base alloys that have theform A3B, where B is a smaller atom than A. In superalloys,these are the common FCC Ni3(Al, Ti) or oc
7、casionally foundHCP Ni3Ti.2.1.3 topologically close-packed (TCP) phases precipi-tated phases in nickel-base alloys, characterized as composedof close-packed layers of atoms forming in basket weave netsaligned with the octahedral planes of the FCC g matrix. Thesegenerally detrimental phases appear as
8、 thin plates, oftennucleating on grain-boundary carbides. TCP phases commonlyfound in nickel alloys are s, , and Laves.3. Significance and Use3.1 This practice can be used to extract carbides, borides,TCP and GCP phases, which can then be qualitatively orquantitatively analyzed by X-ray diffraction
9、or microanalysis.23.2 Careful control of parameters is necessary for reproduc-ible quantitative results. Within a given laboratory, such resultscan be obtained routinely; however, caution must be exercisedwhen comparing quantitative results from different laborato-ries.33.3 Comparable qualitative re
10、sults can be obtained routinelyamong different laboratories using this procedure.34. Apparatus4.1 Cell or Container for Electrolyte A glass vessel ofabout 400-mL capacity is recommended. For the sample sizeand current density recommended later in this procedure,electrolysis can proceed up to about 4
11、 h, and up to about4gofalloy can be dissolved in 250 mL of electrolyte withoutexceeding a metallic ion concentration of 16 g/L. Above thisconcentration, cathode plating has been observed to be morelikely to occur. A mechanism for cooling the electrolyte isrecommended. For example, an ice water bath
12、or water-jacketed cell may be used to keep the electrolyte between 0and 30C.4.2 CathodeMaterial must be inert during electrolysis.Tantalum and platinum sheet or mesh are known to meet thisrequirement. Use of a single wire is to be avoided, sincecathode surface area should be larger than that of samp
13、le.Distance between sample and cathode should be as great aspossible, within the size of cell chosen. For example, a samplewith a surface area of 15 cm2should have no side closer than1.2 cm to the cathode. If the cell is cylindrical, as for the caseof a beaker or the upper part of a separatory funne
14、l, the cathodecould be curved to fit the inner cell wall to facilitate correct1This practice is under the jurisdiction of ASTM Committee E04 on Metallog-raphy and is the direct responsibility of Subcommittee E04.11 on X-Ray andElectron Metallography.Current edition approved Nov. 1, 2004. Published N
15、ovember 2004. Originallyapproved in 1983. Last previous edition approved in 2000 as E963 83 (2000).2Donachie, M. J. Jr., and Kriege, O. H., “Phase Extraction and Analysis inSuperalloysSummary of Investigations by ASTM Committee E-4 Task Group I,”Journal of Materials, Vol 7, 1972, pp. 269278.3Donachi
16、e, M. J. Jr., “Phase Extraction and Analysis in SuperalloysSecondSummary of Investigations by ASTM Subcommittee E04.91,” Journal of Testingand Evaluation, Vol 6, No. 3, 1978, pp. 189195.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States
17、.sample-cathode distance. The sample would then be centeredwithin the cell at the same height as the cathode. The cathodeneed not make a complete ring around the sample nor be morethan 5 cm high.4.3 AnodeThe sample must be suspended in the electro-lyte by a material that is inert during electrolysis
18、. Anodeconnection material should be cleaned to prevent any contami-nating material from falling into the cell. Good electricalcontact should be maintained between the sample wire and thepermanent anode wire from the dc power supply. Two methodsare found to be successful. Either method is subject to
19、disconnection of the sample due to shrinkage, which puts alimit on the electrolysis time:4.3.1 Suspend the sample by platinum or platinum-rhodiumthermocouple wire (20 gauge) wrapped around it to form abasket. To avoid a shielding problem, the ratio of sample areacovered by the wire to the exposed sa
20、mple area should besmall.4.3.1.1 Mechanically attach or spot weld the platinum orplatinum-rhodium thermocouple wire to the sample.4.3.2 If the weld is not immersed, non-inert wire may besubstituted; for example, chromel, nichrome, 300 series stain-less steel, etc. Stop-off lacquer should be used bel
21、ow themeniscus to maintain constant electrolyte level. This alsoeliminates formation of insoluble deposits immediately abovethe meniscus and prevents arcing.4.3.2.1 WarningCare must be taken to prevent arcingbetween anode and cathode which could ignite the methanol.4.4 Power SupplyA variable dc powe
22、r supply capable ofproviding 0 to 5 V is needed to obtain currents from 0 to 1.2 Adepending on total surface area of the sample. For example, asample with total surface area of 15 cm2, electrolyzed at acurrent density of 0.1 A/cm2, requires:15 cm23 0.1 A/cm25 1.2 A (1)4.4.1 Current and voltage fluct
23、uation should be no morethan 65%.A65 % current fluctuation represents a currentdensity fluctuation of about 65 % which, for samples under 15cm2total surface area, is less than or equal to one-half thecurrent density shift due to sample shrinkage over 4 h.Potentiostatic control is not necessary, but
24、may be helpful fordetermining optimum current density when setting up proce-dures for a new alloy.4.5 Membrane FilterMust be solvent and electrolyte re-sistant, with pore size of 0.4 to 0.8 m. Filters made ofpoly(vinyl chloride) (fibrous) or polycarbonate (nonfibrous)meet these requirements and are
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME96319952004STANDARDPRACTICEFORELECTROLYTICEXTRACTIONOFPHASESFROMNIANDNIFEBASESUPERALLOYSUSINGAHYDROCHLORICMETHANOLELECTROLYTE

链接地址:http://www.mydoc123.com/p-533852.html