1、Designation: E 410 08Standard Test Method forMoisture and Residue in Liquid Chlorine1This standard is issued under the fixed designation E 410; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in
2、parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the determination of moistureand residue in liquid chlorine. Lower limits of detection of 10g/g based on a 150-mL sample
3、 are achievable.1.2 This test method describes operations and special appa-ratus for sampling liquid chlorine from cylinders. Samplingother commercial facilities such as tank cars, barges, andstorage tanks require special techniques of manipulation infilling sample cylinders for testing. If conditio
4、ns and facilitiesare favorable, the analysis apparatus may be connected directlyto these larger storage and transportation units and on-the-spottests may be completed.1.3 The analytical methods are empirical and are gravimet-ric. They are applicable to the determination of the residue andmoisture co
5、ntent of commercial grades of liquid chlorine(condensed gaseous product).1.4 Residue is defined as being those substances whichremain in the sample flask after sample volatilization under theconditions of the test. Moisture is defined as the volatilesubstances evolved during volatilization and purgi
6、ng of thesample-residue flask and absorbed on the desiccant containedin the absorption tubes under the conditions of the test. Someof the volatile chlorinated hydrocarbons may also be evolvedfrom the sample residue flask during purge and absorbed, thuscontributing to the apparent moisture analysis v
7、alue.1.5 This test method may be used for determining themoisture content only of gaseous chlorine if suitable andappropriate modifications are made for sample measurementand calculation.1.6 Review the current material safety data sheet (MSDS)for detailed information concerning toxicity, first aid p
8、roce-dures, and safety precautions.1.7 The values stated in inch-pound units are to be regardedas the standard. No other units of measurement are included inthis standard.1.8 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility
9、 of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Specific hazardsstatements are given in Section 7.2. Referenced Documents2.1 ASTM Standards:2E 180 Practice for Determining the Precision of AS
10、TMMethods for Analysis and Testing of Industrial and Spe-cialty Chemicals2.2 Federal Standards:3CFR 173 Title 49 Transportation; Shippers General Re-quirements for Shipments and Packagings, including Sec-tions:173.304 Charging of Cylinders with Liquefied Com-pressed Gas173.314 Requirements for Compr
11、essed Gases in TankCars173.315 Compressed Gases in Cargo Tanks and PortableTank Containers3. Summary of Test Method3.1 Acommon liquid sample of chlorine is recommended toprovide the best results when determining both residue andmoisture simultaneously.3.2 Liquid product sample is transferred from th
12、e samecylinder into a precalibrated, 250-mL sample-residue flask andpermitted to volatilize completely under prevailing environ-mental conditions. The volatilized product (chlorine gas) ispassed through anhydrous magnesium perchlorate desiccantfor absorption of moisture. It is recommended that the e
13、xhaustgas be discharged into a caustic scrubber containing anappropriate amount of 20 % caustic solution to neutralize allthe chlorine. This reaction is exothermic and care should betaken to avoid excess heating by choosing a sufficiently largevolume of caustic solution to serve as a heat sink.3.3 A
14、fter complete volatilization of the sample from theflask, residual chlorine and moisture are expelled from anyresidue by purging with dry air through the absorption systemwhere moisture is recovered and determined gravimetrically.1This test method is under the jurisdiction of ASTM Committee E15 onIn
15、dustrial and Specialty Chemicals and is the direct responsibility of SubcommitteeE15.02 on Product Standards.Current edition approved Dec. 15, 2008. Published January 2009. Originallyapproved in 1970. Last previous edition approved in 2003 as E 410 98 (2003).2For referenced ASTM standards, visit the
16、 ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from Superintendent of Documents, U.S. Government PrintingOffice, Washington, DC 20402.1*A
17、Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.4 Residue remaining in the flask is determined by carefulanalytical weighing, the weight gain calculated as residueconten
18、t of the sample. Moisture is computed from the sum ofthe gain in weight of the two absorption tubes containing thedesiccant. Any gain in weight of the second absorber tubeshould be nominal with respect to that of the first tube in theseries.3.5 The moisture content of a chlorine gas stream isdetermi
19、ned gravimetrically as above, by passing a meteredsample through the moisture absorption system only.4. Significance and Use4.1 This test method provides for the determination ofmoisture and residue in liquid chlorine. The concentrationlevels of these impurities are important factors in manycommerci
20、al uses of liquid chlorine.5. Apparatus5.1 The arrangement and assembly of apparatus for collec-tion and measurement of the analytical sample and volatiliza-tion is shown in Fig. 1.5.2 Sample-Residue Flask (H), Erlenmeyer-type, 250-mLcapacity, equipped with a 35/20 JSground-ball joint.4Apermanent ca
21、libration mark shall be inscribed on the flask atthe 150-mL volume level for sample measurement.5.3 Adapter (G), equipped with a 35/20 JSground-socketjoint attached and sealed as shown in Fig. 1. In addition,appropriate 12/5 JSjoints shall be sealed to the adapter. A balljoint, sealed and closed off
22、 at the end, shall be provided forattachment to the inlet tube after collection of liquid sample inthe sample-residue flask. This shall be held in position with anappropriate clamp during volatilization, then removed andreplaced with appropriate connections from the metered dry-airsupply at the time
23、 of aeration and purge of the sample-residueflask.5.4 A second assembly consisting of a sample-residue flaskand adapter shall be used to facilitate collection and disposal ofsample purge from the cylinder sample line prior to withdrawalof the analytical sample for test.5.5 RegulatorAn appropriate ne
24、edle valve type shall beattached to the cylinder outlet to control and regulate the flowof liquid chlorine from the sample cylinder. Connection (F )between the outlet from this valve and the adapter (G) shall beby a short length of appropriately sized TFE-fluorocarbontubing equipped with a 12/5 JSgr
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME4102008838STANDARDTESTMETHODFORMOISTUREANDRESIDUEINLIQUIDCHLORINE 液态 水分 残余物 标准 检测 方法 PDF

链接地址:http://www.mydoc123.com/p-532713.html