ASTM F90-2009 Standard Specification for Wrought Cobalt-20Chromium-15Tungsten-10Nickel Alloy for Surgical Implant Applications (UNS R30605)《外科植入物用锻造钴-20铬-15钨-10镍合金的标准规范(UNS R30605).pdf
《ASTM F90-2009 Standard Specification for Wrought Cobalt-20Chromium-15Tungsten-10Nickel Alloy for Surgical Implant Applications (UNS R30605)《外科植入物用锻造钴-20铬-15钨-10镍合金的标准规范(UNS R30605).pdf》由会员分享,可在线阅读,更多相关《ASTM F90-2009 Standard Specification for Wrought Cobalt-20Chromium-15Tungsten-10Nickel Alloy for Surgical Implant Applications (UNS R30605)《外科植入物用锻造钴-20铬-15钨-10镍合金的标准规范(UNS R30605).pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 90 09Standard Specification forWrought Cobalt-20Chromium-15Tungsten-10Nickel Alloy forSurgical Implant Applications (UNS R30605)1This standard is issued under the fixed designation F 90; the number immediately following the designation indicates the year of originaladoption or, in the
2、 case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A superscriptepsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This specification covers the requirements for wroughtcobalt-20chromium-15tungsten-10n
3、ickel alloy used for surgi-cal implants. The properties specified apply specifically towrought bar, rod, wire, sheet, and strip, but do not apply tosurgical fixation wire (see Specification F 1091).1.2 The values stated in inch-pound units are to be regardedas standard. The values given in parenthes
4、es are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.2. Referenced Documents2.1 ASTM Standards:2A 751 Test Methods, Practices, and Terminology forChemical Analysis of Steel ProductsE8 Test Methods for Tension Testing of Metallic MaterialsE2
5、9 Practice for Using Significant Digits in Test Data toDetermine Conformance with SpecificationsE45 Test Methods for Determining the Inclusion Contentof SteelE 354 Test Methods for Chemical Analysis of High-Temperature, Electrical, Magnetic, and Other Similar Iron,Nickel, and Cobalt AlloysF 981 Prac
6、tice for Assessment of Compatibility of Bioma-terials for Surgical Implants with Respect to Effect ofMaterials on Muscle and BoneF 1091 Specification for Wrought Cobalt-20Chromium-15Tungsten-10Nickel Alloy Surgical Fixation Wire (UNSR30605)F 2527 Specification for Wrought Seamless and Welded andDraw
7、n Cobalt Alloy Small Diameter Tubing for SurgicalImplants (UNS R30003, UNS R30008, UNS R30035, UNSR30605, and UNS R31537)2.2 Aerospace Material Specification:3AMS 2269 Chemical Check Analysis Limits, WroughtNickel Alloys and Cobalt AlloysAMS 5759 Cobalt Alloy, Corrosion and Heat ResistantBars, Forgi
8、ngs, and Rings, 52Co 20 Cr 10Ni 15W,Solution Heat Treated2.3 ISO Standards:4ISO 5832-5 Wrought Cobalt-Chromium-Tungsten-NickelAlloyISO 6892 Metallic Materials Tensile Testing at AmbientTemperatureISO 9001 Quality SystemRequirements2.4 American Society for Quality (ASQ) Standard:C1 Specification of G
9、eneral Requirements for a QualityProgram53. Classification3.1 BarRound, rectangular, or other complex shapedproduct delivered straightened and cut to defined lengths, witha maximum cross-sectional area of 16 in.2(103 cm2).3.2 WireRound, rectangular, or other complex shapedproduct produced and delive
10、red in coils.3.3 Fine WireWire with diameter or major dimension lessthan 0.063 in. (1.6 mm).4. Ordering Information4.1 Inquiries and orders for material under this specificationshall include the following information:4.1.1 Quantity,4.1.2 ASTM designation and date of issue,4.1.3 Mechanical properties
11、 (see Section 7),4.1.4 Form (bar, rod, wire, sheet, strip),4.1.5 Applicable dimensions including size, thickness,width, and length (exact, random, or multiples) or drawingnumber,4.1.6 Condition (see 5.1),1This specification is under the jurisdiction of ASTM Committee F04 onMedical and Surgical Mater
12、ials and Devices and is the direct responsibility ofSubcommittee F04.12 on Metallurgical Materials.Current edition approved June 1, 2009. Published July 2009. Originally approvedin 1968. Last previous edition approved in 2007 as F 90 07.2For referenced ASTM standards, visit the ASTM website, www.ast
13、m.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from Society of Automotive Engineers (SAE), 400 CommonwealthDr., Warrendale, PA 15096-0001, http:/www.sae.org.4Av
14、ailable from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.5Available from American Society for Quality (ASQ), 600 N. Plankinton Ave.,Milwaukee, WI 53203, http:/www.asq.org.1*A Summary of Changes section appears at the end of this stan
15、dard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4.1.7 Finish (see 5.2),4.1.8 Other requirements.5. Materials and Manufacture5.1 ConditionBar, wire, sheet, and strip shall be furnishedto the purchaser, as specified, in the anneale
16、d or cold-workedcondition.5.2 Finish:5.2.1 Bar and wire shall be furnished bright annealed, colddrawn, pickled, ground, or ground and polished, as specified bythe purchaser.5.2.2 Sheet shall be furnished bright annealed, pickled,cold-rolled, or polished, as specified by the purchaser.6. Chemical Req
17、uirements6.1 The heat analysis shall conform to the chemical com-position of Table 1. The supplier shall not ship material that isoutside the limits specified in Table 1.6.1.1 Requirements for the major and minor elementalconstituents are listed in Table 1. Also listed are importantresidual elements
18、. Analysis for elements not listed in Table 1 isnot required to verify compliance with this specification.6.2 Product AnalysisThe product analysis is either for thepurpose of verifying the composition of a heat or lot or todetermine variations in the composition within the heat.6.2.1 Acceptance or r
19、ejection of a heat or lot of materialmay be made by the purchaser on the basis of this productanalysis.6.2.2 Product analysis tolerances do not broaden the speci-fied heat analysis requirements but instead cover variationsbetween laboratories in the measurement of chemical content.Product analysis l
20、imits shall be as specified in Table 2.6.3 For referee purposes, Test Methods E 354 shall be used.6.4 Methods and practices relating to chemical analysisrequired by this specification shall be in accordance with TestMethods A 751.7. Mechanical Requirements7.1 The material in the annealed condition s
21、hall conform tothe mechanical properties specified in Tables 3 and 4.7.2 Material in the cold worked condition shall conform tothe mechanical properties specified in Table 3.7.3 Tensile properties shall be determined in accordancewith Test Methods E8. Perform at least one tension test fromeach lot.
22、Should any test piece not meet the specified require-ments, test two additional test pieces representative of the samelot, in the same manner, for each failed test piece. The lot shallbe considered in compliance only if all additional test piecesmeet the specified requirements.7.3.1 Tensile tests re
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF902009STANDARDSPECIFICATIONFORWROUGHTCOBALT20CHROMIUM15TUNGSTEN10NICKELALLOYFORSURGICALIMPLANTAPPLICATIONSUNSR30605

链接地址:http://www.mydoc123.com/p-532689.html