ASTM E2844-2015e1 Standard Specification for Demonstrating That a Building&x2019 s Location Provides Access to Public Transit《证明建筑位置提供有公共交通通行路径的标准规格》.pdf
《ASTM E2844-2015e1 Standard Specification for Demonstrating That a Building&x2019 s Location Provides Access to Public Transit《证明建筑位置提供有公共交通通行路径的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2844-2015e1 Standard Specification for Demonstrating That a Building&x2019 s Location Provides Access to Public Transit《证明建筑位置提供有公共交通通行路径的标准规格》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E2844 151Standard Specification forDemonstrating That a Buildings Location Provides Accessto Public Transit1This standard is issued under the fixed designation E2844; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the
2、 year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEKeywords in Section 7 were corrected editorially in September 2015.1. Scope1.1 This specification provides requireme
3、nts for demon-strating that a buildings location provides a minimal level ofaccess to public transit such that building occupants can rely onpublic transit to travel to places of employment and to runtypical errands.1.2 This specification addresses a single indicator regardingthe environmental perfo
4、rmance related to a buildings location.It provides one option for evaluating whether a building islocated in such a way as to minimize the impacts associatedwith occupants travel.NOTE 1The indicator in and of itself is insufficient to imply any levelof “sustainability” for the building or the neighb
5、orhood. Similarly, abuildings failure to meet this specification does not necessarily signify alack of sustainability. Other indicators may be more appropriate for thatbuilding or region; those indicators are outside the scope of this specifi-cation.1.3 The values stated in inch-pound units are to b
6、e regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of th
7、e user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E631 Terminology of Building ConstructionsE2114 Terminology for Sustainability Relative to the Perfor-mance
8、 of Buildings3. Terminology3.1 Definitions:3.1.1 For terms related to building, refer to TerminologyE631.3.1.2 For terms related to sustainability relative to theperformance of buildings, refer to Terminology E2114.3.2 Definitions of Terms Specific to This Standard:3.2.1 access location, nclosest po
9、int for the public toboard a transit vehicle on a given route.3.2.2 headway, ntime interval between public transit ve-hicles moving in the same direction on a particular route.3.2.2.1 DiscussionIf multiple routes at a given stop share60 % or more of their route, they can be viewed as the sameroute f
10、or purposes of calculating headways.3.2.3 local transit, npublic transit that meets one or bothof the following characteristics: (1) operates within the sameright-of-way as automobile traffic or (2) the distance betweenits access locations averages less than 1/3 mile (0.5 km).3.2.3.1 DiscussionTrans
11、it types that typically meet thisdefinition include local bus and streetcar.3.2.4 off-peak hours, nall hours that are not peak hours.3.2.5 peak hours, nhour(s) of greatest commuting in theregion in the morning and evening as identified by the localjurisdiction.3.2.6 public transit, ntransportation b
12、y a land, aerial, orwater conveyance that provides to the public regular andcontinuing transportation over fixed routes but does not includeprivate shuttle, school or charter bus, or intracity transportationsuch as a taxi.3.2.7 rapid transit, npublic transit that has both of thefollowing characteris
13、tics: (1) it operates within a dedicatedright-of-way and (2) the average distance between its accesslocations is greater than 1/3 mile (0.5 km).3.2.7.1 DiscussionTransit types that typically meet thisdefinition include bus rapid transit, light rail, heavy or passen-ger rail, and ferry service.1This
14、specification is under the jurisdiction of ASTM Committee E60 onSustainability and is the direct responsibility of Subcommittee E60.01 on Buildingsand Construction.Current edition approved Aug. 1, 2015. Published August 2015. DOI: 10.1520/E2844-15E01.2For referenced ASTM standards, visit the ASTM we
15、bsite, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United Sta
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME28442015E1STANDARDSPECIFICATIONFORDEMONSTRATINGTHATABUILDINGX2019SLOCATIONPROVIDESACCESSTOPUBLICTRANSIT

链接地址:http://www.mydoc123.com/p-531988.html