ASTM E2730-2010(2015)e2 Standard Practice for Calibration and Use of Thermocouple Reference Junction Probes in Evaluation of Electronic Reference Junction Compensation Circuits《校准和.pdf
《ASTM E2730-2010(2015)e2 Standard Practice for Calibration and Use of Thermocouple Reference Junction Probes in Evaluation of Electronic Reference Junction Compensation Circuits《校准和.pdf》由会员分享,可在线阅读,更多相关《ASTM E2730-2010(2015)e2 Standard Practice for Calibration and Use of Thermocouple Reference Junction Probes in Evaluation of Electronic Reference Junction Compensation Circuits《校准和.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E2730 10 (Reapproved 2015)2Standard Practice forCalibration and Use of Thermocouple Reference JunctionProbes in Evaluation of Electronic Reference JunctionCompensation Circuits1This standard is issued under the fixed designation E2730; the number immediately following the designation in
2、dicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTENote 12 was moved to a new location below Table
3、 2 in November 2015.1. Scope1.1 This guide covers methods of calibration and use ofthermocouple reference junction probes (cold junction com-pensation probes) in the evaluation of electronic referencejunction compensation circuits. Their use with instruments thatmeasure only voltage is also covered.
4、1.2 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish app
5、ro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E220 Test Method for Calibration of Thermocouples ByComparison TechniquesE230 Specification and Temperature-Electromotive Force(EMF) Tables for Sta
6、ndardized ThermocouplesE344 Terminology Relating to Thermometry and Hydrom-etryE563 Practice for Preparation and Use of an Ice-Point Bathas a Reference TemperatureE1129/E1129M Specification for Thermocouple ConnectorsE1684 Specification for Miniature Thermocouple Connec-torsE1750 Guide for Use of Wa
7、ter Triple Point CellsE2623 Practice for Reporting Thermometer Calibrations2.2 Other References:NIST Monograph 175 Temperature-Electromotive ForceReference Functions and Tables for the Letter-DesignatedThermocouple Types Based on the ITS-90ASTM MNL12 Manual On The Use Of Thermocouples InTemperature
8、MeasurementBIPM JCGM 100:2008 Evaluation of Measurement DataGuide to the Expression of Uncertainty in Measurement3. Terminology3.1 DefinitionsThe definitions given in Terminology E344shall apply to this guide.3.2 Definitions of Terms Specific to This Standard:3.2.1 correction, nan offset value added
9、 to the result of ameasurement to obtain a correct result.NOTE 1This definition is from Test Method E220.3.2.2 reference junction compensation, nthe electrical cor-rection of the indication of a thermocouple such that thecorrected indication is equivalent to the emf or temperature theinstrument woul
10、d indicate if the reference junctions werephysically maintained at 0C.3.2.3 reference junction probe, na probe constructed fromthermocouple materials and high purity copper wire for thepurpose of serving as the reference junction for a thermocoupleassembly. Reference junction probes may be construct
11、ed aspart of the measuring probe or they can be manufacturedseparately and later attached to thermocouple sensors via plugsor other connection types.3.2.4 UUT, nUnit Under Test.4. Summary of Guide4.1 Calibration of a Reference Junction Probe (RJP) con-sists of establishing the emf error in the RJP r
12、elative to theapplicable thermocouple reference function by placing themeasuring junction and the reference junctions at knowntemperatures while measuring the voltage with a digital volt-meter (DVM) or potentiometer. Three methods are described1This practice is under the jurisdiction ofASTM Committe
13、e E20 on TemperatureMeasurement and is the direct responsibility of Subcommittee E20.04 on Thermo-couples.Current edition approved June 15, 2015. Published June 2015. Originallyapproved in 2010. Last previous edition approved in 2010 as E2730 10.DOI:10.1520/E2730-10R15E02.2For referenced ASTM standa
14、rds, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA
15、19428-2959. United States1for establishing the two known temperatures and thus thetemperature difference. For the temperature measurement,many devices such as Standard Platinum Resistance Thermom-eters (SPRTs), Platinum Resistance Thermometers (PRTs),thermistors, or thermocouples, and a variety of r
16、eadout instru-ments are suitable, depending on the required accuracy. Themeasured voltage at the copper leads indicates the emf asso-ciated with the temperature difference of the references. Erroris determined by comparing the observed emf to the calculatedemf for the known temperature difference. T
17、he emf error isthen applied as a correction. The corrected emf can then beconverted to temperature.NOTE 2In particular, cold work should be avoided in the sections ofcopper and thermocouple wire that pass from the top of the ice bath toambient temperature continuing on to the terminal connection. Ca
18、refuldesign of the RJP, with supporting sleeve and strain relief, can minimizecold work in these sections.4.2 Use of the calibrated RJP consists of applying thecorrections obtained during calibration appropriately for themode of use. Three modes of use with corresponding applica-tion equations are d
19、escribed.NOTE 3Homogeneity is assumed in both the thermocouple and copperwires. Care should be taken to minimize the stress induced over time andduring use on both sets of wire. Cold work in particular should be avoidedin the sections of the copper and thermocouple wire from a distance 5 cm(2 in.) b
20、elow the top of the ice/water mixture to a distance 5 cm (2 in.)above the top of the ice-point bath.NOTE 4Proper operation of the measuring instruments is not de-scribed in this guide. To ensure correct results, the operator mustunderstand and apply proper technique in the use of all measuringinstru
21、ments involved.5. Significance and Use5.1 Many electronic instruments that are designed to beused with thermocouples use some method of reference junc-tion compensation. In many industrial applications it may beimpractical to use a physical ice bath as a temperaturereference in a thermocouple circui
22、t. The instrument musttherefore be able to measure the temperature at the point ofelectrical connection of the thermocouple and either add orsubtract voltage to give a corrected equivalent of what thatthermocouple would indicate had there physically been 0Creference junctions present in the circuit.
23、 There are two typesof instruments that generally apply these techniques: electronicthermometer readouts that use a thermocouple as the sensor,and calibrators designed to calibrate these digital thermometerreadouts. Additionally, the probe and circuit described in thisguide can be used with a voltme
24、ter to emulate a thermometeror a voltage source to calibrate temperature-indicating instru-mentation. In all cases the probe must be calibrated if trace-ability or an uncertainty analysis, or both, is required.6. Reagents6.1 Laboratory or commercially produced distilled water isrequired to create an
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME273020102015E2STANDARDPRACTICEFORCALIBRATIONANDUSEOFTHERMOCOUPLEREFERENCEJUNCTIONPROBESINEVALUATIONOFELECTRONICREFERENCEJUNCTIONCOMPENSATIONCIRCUITS

链接地址:http://www.mydoc123.com/p-531780.html