1、Designation: E2623 081E2623 14Standard Practice forReporting Thermometer Calibrations1This standard is issued under the fixed designation E2623; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in
2、 parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1 NOTEThe title was corrected editorially in May 2009.1. Scope1.1 This practice contains reporting requirements for thermometer calibrations included in AST
3、M Committee E20E20 TestMethods.1.2 This practice covers reports of calibration for radiation thermometers, liquid-in-glass thermometers, resistancethermometers, digital thermometers, and new thermocouples.NOTE 1This practice does not apply to used thermocouples.1.3 This standard does not purport to
4、address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E77 Test Met
5、hod for Inspection and Verification of ThermometersE344 Terminology Relating to Thermometry and HydrometryE1137 Specification for Industrial Platinum Resistance Thermometers2.2 Other Standards:Standards or Guides:ANSI/NCSL Z540-1-1994Z540.3-2006 American National Standard for CalibrationCalibration
6、Laboratories and Measuringand Test EquipmentGeneral Requirements3ISO/IEC 17025:2005 General Requirements for the Competence of Testing and Calibration Laboratories3JCGM100:2008 Evaluation of Measurement DataGuide to the Expression of Uncertainty in MeasurementISO/IEC Guide 98-3 Uncertainty of Measur
7、ementPart 3: Guide to the Expression of Uncertainty in Measurement(GUM:1995)NIST Technical Note 1297 Guidelines for Evaluating and Expressing the Uncertainty of NIST Measurement Results, 1994EditionUKAS M3003 The Expression of Uncertainty and Confidence in Measurement, Edition 2ANSI/NCSL Z540.2-1997
8、 (R2002) U.S. Guide to the Expression of Uncertainty in Measurement3. Terminology3.1 DefinitionsDefinitions given in Terminology E344, unless otherwise defined herein, apply to terms as used in this practice.3.2 Definitions of Terms Specific to This Standard:3.2.1 correction, nnumerical value added
9、to the uncorrected result of a measurement to compensate for errors.3.2.1.1 Discussion1 This practice is under the jurisdiction ofASTM Committee E20 on Temperature Measurement and is the direct responsibility of Subcommittee E20.07 on Fundamentalsin Thermometry.Current edition approved Nov. 1, 2008D
10、ec. 15, 2014. Published January 2009January 2015. Originally approved in 2008. Last previous edition approved in 2008 asE2623 081. DOI: 10.1520/E2623-08E01.10.1520/E2623-14.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For An
11、nual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.3 Available from American National Standards Institute (ANSI), 25 W. 43rd St., 4th Floor, New York, NY 10036, http:/www.ansi.org.This document is not an ASTM standard and is intended only
12、to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current version
13、of the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1The correction is equal to the negative of the estimated errors. Since the systematic error cannot be known
14、 perfectly, thecompensation cannot be complete.3.2.2 error, nthe indication of a thermometer or temperature measuring device minus athe true value of the correspondinginput quantity.3.2.2.1 DiscussionSince the true value cannot be determined, in practice a conventional true value is used. This conce
15、pt applies mainly wherewhenthe instrument is compared to a reference standard.3.2.3 gradient zone, nthe section of a thermocouple that is exposed during a measurement to temperatures in the range fromtamb + 0.1(tm tamb) to tamb + 0.9(tm tamb), where tamb is ambient temperature and tm is the temperat
16、ure of the measuringjunction.junction (all in C).3.2.3.1 DiscussionThis term is used in thermocouple calibration reports as part of the description of the thermal profile along the length of thethermocouple.Although a thermocouple emf is a function of the measuring and reference junction temperature
17、s, the emf is actuallygenerated along the length of the thermocouple, wherever the thermoelements pass through a temperature gradient. The gradientzone definition is intended to describe, in an approximate way, the section of thermocouple that created most of the emf duringthe calibration.3.2.4 half
18、-maximum heated length, nthe distance between the tip of the temperature sensor and the position along the lengthof the sensor leads or sheath where the temperature equals the average of the calibration-point and ambient temperatures.3.2.4.1 DiscussionThis term is used in thermocouple calibration re
19、ports as part of the description of the thermal profile along the length of thethermocouple.4. Summary of Practice4.1 This practice describes the required information necessary for reporting results of temperature calibrations included inASTM Test Methods.5. Significance and Use5.1 This practice is
20、adequate for use with all ASTM Test Methods which require the reporting of temperature measurements.5.2 The Report of Calibration, however named, is the physical output of the calibration laboratory. It shall be prepared so thatboth the results of the measurement(s) and the non-technical information
21、 necessary to support those results are conveyed in amanner that ensures accurate communication and justification of the results to the benefit of all concerned.results.5.3 This practice is not meant to supersede requirements of other standards practice such as ISO/IEC 17025 or ANSI/NCSLZ540-1.Z540.
22、3.6. Procedure6.1 Requirements for Written Report The requirements in 6.1.1 through 6.1.14 are mandatory for all written reports issued incompliance with this practice. SectionsSubsections 6.1.15 through 6.1.19 include general provisions for information that may beomitted if not required by a calibr
23、ation procedure or client/user.6.1.1 Title ExamplesReport of Calibration, Calibration Certificate, Test Report or Test Certificate.6.1.2 Name and address of the laboratory and location where the calibration was performed, if different from the laboratoryaddress.6.1.3 Unique identification of the rep
24、ort or certificate, and on each page an identification in order to ensure that the page isrecognized as part of the report or certificate, a clear identification of the end of the report or certificate, and the page number andtotal number of pages.6.1.4 Name and address of the client.6.1.5 Statement
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME26232014STANDARDPRACTICEFORREPORTINGTHERMOMETERCALIBRATIONS 温度计 校准 报告 标准 实践 规程 PDF

链接地址:http://www.mydoc123.com/p-531570.html