1、Designation: E2190 10Standard Specification forInsulating Glass Unit Performance and Evaluation1This standard is issued under the fixed designation E2190; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A
2、 number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers preassembled permanentlysealed insulating glass units with one or two airspaces andpreassembled insulating g
3、lass units with capillary tubes inten-tionally left open.1.2 This specification is applicable only to sealed insulatingglass units that are constructed with glass.1.3 This specification is applicable to both double-glazedand triple-glazed insulating glass units; for triple-glazed insu-lating glass u
4、nits where both of the outer lites are glass andinner lite is either glass or a suspended film.1.4 The qualification of test specimens is based on frost/dewpoint and on the absence of fog after the specified testdurations.1.5 The qualification of argon gas filled test specimens isbased on the qualif
5、ications in 1.3 and maintaining the specifiedargon gas amounts before and after testing to Test MethodE2188.1.6 Qualification under this specification is intended toprovide a basis for evaluating the durability of sealed insulatingglass units.1.7 This specification is not applicable to sealed insula
6、tingglass units containing a spandrel glass coating due to testmethod limitations.1.8 This specification does not cover other physical require-ments such as appearance, thermophysical properties, heat andlight transmission, and glass displacement.NOTE 1Sealed insulating glass units qualified accordi
7、ng to thisspecification are not necessarily suitable for structurally glazed applica-tions. Factors such as sealant longevity when exposed to long termultraviolet light and the structural properties of the sealant must bereviewed for these applications. For more information on the requirementsfor st
8、ructural sealant glazing applications, refer to Specification C1369,Guide C1249, and Test Method C1265.1.9 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.10 This standard does not purport to address all of thesafety concerns,
9、 if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C162 Terminology of Glass and Glass Products
10、C717 Terminology of Building Seals and SealantsC1036 Specification for Flat GlassC1249 Guide for Secondary Seal for Sealed InsulatingGlass Units for Structural Sealant Glazing ApplicationsC1265 Test Method for Determining the Tensile Propertiesof an Insulating Glass Edge Seal for Structural GlazingA
11、pplicationsC1369 Specification for Secondary Edge Sealants for Struc-turally Glazed Insulating Glass UnitsE546 Test Method for Frost/Dew Point of Sealed InsulatingGlass UnitsE631 Terminology of Building ConstructionsE2188 Test Method for Insulating Glass Unit PerformanceE2189 Test Method for Testing
12、 Resistance to Fogging inInsulating Glass UnitsE2269 Test Method for Determining Argon Concentrationin Sealed Insulating Glass Units using Gas Chromatogra-phyE2649 Test Method for Determining Argon Concentrationin Sealed Insulating Glass Units Using Spark EmissionSpectroscopy3. Terminology3.1 Defini
13、tion of Terms:3.1.1 For definitions of terms found in this Specification,refer to Terminologies C162, C717, and E631.3.2 Definitions of Terms Specific to This Standard:3.2.1 sealed insulating glass unit, na preassembled unit,comprising lites of glass, which are sealed at the edges and1This specifica
14、tion is under the jurisdiction of ASTM Committee E06 onPerformance of Buildings and is the direct responsibility of Subcommittee E06.22on Durability Performance of Building Constructions.Current edition approved Nov. 1, 2010. Published November 2010. Originallyapproved in 2002. Last previous edition
15、 approved in 2008 as E2190 08. DOI:10.1520/E2190-10.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyrigh
16、t ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.separated by dehydrated space(s), intended for vision areas ofbuildings. The unit is normally used for windows, windowwalls, picture windows, sliding doors, patio doors, or othertypes of fenestr
17、ation.4. Performance Requirements4.1 To pass the specification for Test Method E2188:4.1.1 Six units shall complete all testing unbroken. Theseunits shall have frost/dew points determined and reported. Thefinal frost/dew points shall be 40C or colder when measuredin accordance with Test Method E546
18、or equivalent.4.2 To pass the specification for Test Method E2189:4.2.1 The units that complete Test Method E2189 shall haveno fog visible after testing.4.3 To pass the specification for argon filled units:4.3.1 The average initial argon gas concentration of thespecimens prior to testing to Test Met
19、hod E2188 shall be aminimum of 90 %. No individual test specimen shall have anargon concentration of less than 50 %.4.3.2 The average final argon gas concentration of the sixspecimens after testing to Test Method E2188 shall be aminimum of 80 %. No individual test specimen shall have anargon concent
20、ration of less than 50 %.4.4 FogNo fog shall be visible after testing in accordancewith Test Method E2189.5. Test Specimens5.1 Each test specimen shall measure 355 6 6mmby5056 6 mm and shall be composed of two or three lites of glass.5.2 The glass and airspace thickness(es) for qualificationunder th
21、is specification shall be 4 mm glass with 12 mmairspace or 5 mm glass with 6 mm airspace.5.3 For triple-glazed units, 4 mm glass with 6 mm airspacesshall be used.5.4 If the required glass constructions in 5.2 and 5.3 are notavailable form the submitting manufacturer, then thicker glassor wider airsp
22、aces, or both shall be allowed. (For example,using 6 mm glass with 12 mm airspace.) This may result in amore rigorous test.5.5 All of the values in 5.2 through 5.4 are nominal.5.5.1 Tolerance of glass thickness shall be in accordancewith Specification C1036.5.5.2 Airspace tolerance(s) shall be 60.8
23、mm.5.6 If specifying internal components, then these compo-nents shall be present in the test specimens made for testing toTest Method E2189.5.7 Twelve double-glazed test specimens shall be submittedwhen testing to this specification. If specifying internal com-ponents, three of these specimens shal
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME21902010STANDARDSPECIFICATIONFORINSULATINGGLASSUNITPERFORMANCEANDEVALUATION 绝缘 玻璃 元件 性能 评价 标准规范

链接地址:http://www.mydoc123.com/p-530508.html