1、Designation: E 2190 02Standard Specification forInsulating Glass Unit Performance and Evaluation1This standard is issued under the fixed designation E 2190; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision.
2、 A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification is applicable to preassembled perma-nently sealed insulating glass units with one or two airspacesand preassembl
3、ed insulating glass units with capillary tubesintentionally left open.1.2 This specification is applicable only to sealed insulatingglass units that are constructed with glass.1.3 The qualification of test specimens is based on frost/dewpoint and on the absence of fog after the specified testduratio
4、ns.1.4 Qualification under this specification is intended toprovide a basis for evaluating the durability of sealed insulatingglass units.1.5 This specification is not applicable to sealed insulatingglass units containing a spandrel glass coating due to testmethod limitations.1.6 This specification
5、does not cover other physical require-ments such as appearance, thermophysical properties, heat andlight transmission, and glass displacement.NOTE 1Sealed insulating glass units qualified according to thisspecification are not necessarily suitable for structurally glazed applica-tions. Factors such
6、as sealant longevity when exposed to long termultraviolet light and the structural properties of the sealant must bereviewed for these applications. For more information on the requirementsfor structural sealant glazing applications refer to Specification C 1369,Guide C 1249, and Test Method C 1265.
7、1.7 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory requirements prior to use.2. Referenced
8、Documents2.1 ASTM Standards:C 162 Terminology of Glass and Glass Products2C 717 Terminology of Building Seals and Sealants3C 1036 Specification for Flat Glass2C 1249 Guide for Secondary Seal for Sealed InsulatingGlass Units for Structural Sealant Glazing Applications3C 1265 Test Method for Determini
9、ng the Tensile Propertiesof an Insulating Glass Edge Seal for Structural GlazingApplications3C 1369 Specification for Edge Sealants for StructurallyGlazed Insulating Glass Units3E 546 Test Methods for Frost Point of Sealed InsulatingGlass Units4E 631 Terminology of Building Constructions4E 2188 Test
10、 Method for Insulating Glass Units Perfor-mance5E 2189 Test Method for Testing Resistance to Fogging inInsulating Glass Units53. Terminology3.1 Definition of Terms:3.1.1 For definitions of terms found in this Specification,refer to Terminology C 717 , Terminology C 162 and Termi-nology E 631.3.2 Def
11、initions of Terms Specific to This Standard:3.2.1 sealed insulating glass unit, na preassembled unit,comprising lites of glass, which are sealed at the edges andseparated by dehydrated space(s), intended for vision areas ofbuildings. The unit is normally used for windows, windowwalls, picture window
12、s, sliding doors, patio doors, or othertypes of fenestration.4. Performance Requirements4.1 The six units that complete the weather cycle and highhumidity phases of Test Method E 2188 unbroken shall havethe frost/dew point determined and reported.4.2 Initial, intermediate (after the weather cycle ph
13、ase) andfinal frost/dew points (after final high humidity test) shall bedetermined. For triple pane units, the frost/dew point isdetermined for all airspaces. The final frost/dew points shall be40C or colder when measured in accordance with TestMethod E 546 or equivalent.4.3 Final frost/dew points s
14、hall be determined after 24 h butno later than 7 days.4.4 FogNo fog shall be visible after testing in accordancewith Test Method E 2189.1This specification is under the jurisdiction of ASTM Committee E06 onPerformance of Buildings and is the direct responsibility of Subcommittee E06.22on Durability
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME21902002STANDARDSPECIFICATIONFORINSULATINGGLASSUNITPERFORMANCEANDEVALUATION 绝缘 玻璃 器件 性能 评价 标准规范

链接地址:http://www.mydoc123.com/p-530506.html