ASTM E1815-2006 Standard Test Method for Classification of Film Systems for Industrial Radiography《工业用射线照相胶片系统分类的标准试验方法》.pdf
《ASTM E1815-2006 Standard Test Method for Classification of Film Systems for Industrial Radiography《工业用射线照相胶片系统分类的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1815-2006 Standard Test Method for Classification of Film Systems for Industrial Radiography《工业用射线照相胶片系统分类的标准试验方法》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 1815 06Standard Test Method forClassification of Film Systems for Industrial Radiography1This standard is issued under the fixed designation E 1815; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last re
2、vision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers a procedure for determinationof the performance of film systems used for industrial radiog-raphy. Th
3、is test method establishes minimum requirements thatcorrespond to system classes.1.2 This test method is to be used only for direct exposure-type film exposed with lead intensifying screens. The perfor-mance of films exposed with fluorescent (light-emitting) inten-sifying screens cannot be determine
4、d accurately by this testmethod.1.3 The values stated in SI units are to be regarded asstandard. The values given in brackets are for information only.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this
5、 standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E94 Guide for Radiographic ExaminationE 999 Guide for Controlling the Quality of Industrial Ra-diographic Film Processing
6、E 1079 Practice for Calibration of Transmission Densitom-etersE 1316 Terminology for Nondestructive Examinations2.2 ANSI Standards:3PH 2.40 Root Mean Square (rms) Granularity of Film(Images on One Side Only) Method of Measuring2.3 ISO Standards:3ISO 5-2 Photography Density MeasurementsPart 2: Geo-me
7、tric Conditions for Transmission DensityISO 5-3 Photography Density MeasurementsPart 3:Spectral ConditionsISO 7004 PhotographyIndustrial Radiographic Film, De-termination of ISO Speed and Average Gradient WhenExposed to X and Gamma Radiation2.4 DIN Standard:3EN 584-1 Non-Destructive TestingIndustria
8、l Radio-graphic FilmClassification of Film Systems3. Terminology3.1 DefinitionsFor definitions of terms used in this testmethod, refer to Terminology E 1316.3.2 Definitions of Terms Specific to This Standard:3.2.1 film systemthe film and associated film-processingrequirements in accordance with the
9、criteria established by themanufacturers of the film and processing chemicals.3.2.2 gradient Gthe slope of the characteristic curve at acertain density, D, and a measure of the contrast of the filmsystem.3.2.3 granularity, sDnonuniformity of density in a radio-graphic image typically caused by rando
10、m, statistical group-ings of individual silver particles in processed film.3.2.4 ISO speed Sdetermined by the dose Ks, measured ingray at a specified optical density, D, in the radiograph.4. Significance and Use4.1 This test method provides a relative means for classifi-cation of film systems used f
11、or industrial radiography. The filmsystem consists of the film and associated processing system(the type of processing and processing chemistry). Section 6describes specific parameters used for this test method. Ingeneral, the classification for hard X-rays, as described inSection 6, can be transfer
12、red to other radiation energies andmetallic screen types, as well as screens without films. Theusage of film system parameters outside the energy rangesspecified may result in changes to a film/system performanceclassification.1This test method is under the jurisdiction of ASTM Committee E07 onNonde
13、structive Testing and is the direct responsibility of Subcommittee E07.01 onRadiology (X and Gamma) Method.Current edition approved Feb. 1, 2006. Published February 2006. Originallyapproved in 1996. Last previous edition approved in 2001 as E 1815 - 96 (2001).2For referenced ASTM standards, visit th
14、e ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY
15、10036.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4.1.1 The film performance is described by signal and noiseparameters. The signal is represented by gradient and the noiseby granularity.4.1.2 A film is assigned a particular clas
16、s if it meets all fourof the minimum performance parameters: for Gradient G atD = 2.0 and D = 4.0, granularity sDat D = 2.0, and gradient/noise ratio at D = 2.0.4.2 This test method describes how the parameters shall bemeasured and demonstrates how a classification table can beconstructed.4.3 Manufa
17、cturers of industrial radiographic film systemswill be the users of this test method. The result is a classifica-tion table as shown by the example given in Table 1. This tablealso includes speed data for user information. Users of indus-trial radiographic film systems may also perform the tests and
18、measurements outlined in this test method, provided that therequired test equipment is used and the methodology isfollowed strictly.4.4 The publication of classes for industrial radiographyfilm systems will enable specifying bodies and contractingparties to agree to particular system classes, which
19、are capableof providing known image qualities. See 7.2.4.5 European standard EN 584-1 describes a similar methodfor classification of film systems for industrial radiography, butits class definitions and number of classes do not align exactlywith this test method. International users of these standa
20、rdsshould be aware of these differences for their particularapplications.NOTE 1ASTM research report E071005 contains documentation oftechnical methods used during the development of this test method.45. Sampling and Storage5.1 For determination of the gradient and granularity of afilm system, it is
21、important that the samples evaluated yield theaverage results obtained by users. This will require evaluatingseveral different batches periodically, under the conditionsspecified in this test method. Prior to evaluation, the samplesshall be stored in accordance with the manufacturers recom-mendation
22、s for a length of time to simulate the average age atwhich the product is normally used. Several independentevaluations shall be made to ensure the proper calibration ofequipment and processes. The basic objective in selecting andstoring samples as described above is to ensure that the filmcharacter
23、istics are representative of those obtained by a con-sumer at the time of use.6. Procedure6.1 Principle:6.1.1 Film to be tested shall be exposed to X-rays fromtungsten target tubes. Inherent filtration of the tube, plus anadditional copper filter located as close to the target as possible,shall prov
24、ide filtration equivalent to 8.00 6 0.2 mm of copper.6.1.2 The film system includes a front and a back screen of0.02 to 0.25-mm lead. If single-coated films are used, theemulsion-coated surface must face the X-ray tube. Vacuum orpressure cassettes may be used to ensure sufficient contactbetween the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME18152006STANDARDTESTMETHODFORCLASSIFICATIONOFFILMSYSTEMSFORINDUSTRIALRADIOGRAPHY 工业 射线 照相 胶片 系统

链接地址:http://www.mydoc123.com/p-529521.html