1、Designation: E 1061 01 (Reapproved 2007)Standard Specification forDirect-Reading Liquid Crystal Forehead Thermometers1This standard is issued under the fixed designation E 1061; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the y
2、ear of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers direct-reading liquid crystalforehead thermometers designed to monitor trends or mea
3、surehuman forehead surface temperatures, or both.1.2 Thermometers covered by this specification are gener-ally available in continuous or intermittent reading modes.Thermometers meeting the requirements specified herein shallbe considered as complying with this specification.1.3 The following precau
4、tionary caveat pertains only to thetest method portion, Section 5, of this specification. Thisstandard does not purport to address all of the safety concerns,if any, associated with its use. It is the responsibility of the userof this standard to consult and establish appropriate safety andhealth pr
5、actices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E 344 Terminology Relating to Thermometry and Hydrom-etry3. Terminology3.1 DefinitionsFor definitions of terms used in this speci-fication, refer to Terminology E 344.3.2 Definiti
6、ons of Terms Specific to This Standard:3.2.1 center green (CG) or mid green (MG), nthat tem-perature which unifies the visual and instrumental evaluationmethods and is defined by the equation:CG 5 MG 5SG 1 SB25 T520See 3.2.5.2 for description of T520.3.2.2 color play, nthe predictable sequence of co
7、lorsexhibited by a liquid crystal formulation as it passes through itsactive temperature range. For example, as temperature in-creases, a formulation exhibits successive tan, red, green, andblue colors.3.2.3 manufacturing lot, n(1) in the case of continuousmanufacturing processes, a lot is a specifi
8、cally identifiedamount produced in a unit of time or quantity in a manner thatassumes its having uniform characteristics and quality withinspecified limits.(2) In the case of batch processes, a lot means a batch orspecifically identified portion of a batch assumed to haveuniform characteristics and
9、quality within specified limits.3.2.4 sequencing, na characteristic whereby the thermalprofiles of the liquid crystal formulations of a given thermom-eter follow each other in an orderly predetermined manner.3.2.5 specific color phenomena, n (using instrumentalmethods of evaluation):3.2.5.1 bluethat
10、 temperature at which the intensity of 470nm light reflected by the liquid crystal is maximum, symbol-ized as T470.3.2.5.2 greenthat temperature at which the intensity of520 nm light reflected by the liquid crystal is maximum,symbolized as T520.3.2.5.3 redthat temperature at which the intensity of 6
11、50nm light reflected by the liquid crystal is maximum, symbol-ized as T650.3.2.6 start of blue (SB), nthat temperature at which theliquid crystal first begins to reflect blue light, which is definedas light having a wavelength of 491 nm.3.2.7 start of green (SG), nthat temperature at which theliquid
12、 crystal first begins to reflect green light, which is definedas light having a wavelength of 575 nm.3.2.8 start of red (SR), nthat temperature at which theliquid crystal first begins to reflect red light, which is defined aslight having a wavelength of 675 nm.3.2.9 thermal profile, ntemperatures at
13、 which specificcolor phenomena occur in a liquid crystal thermometer.1This specification is under the jurisdiction of ASTM Committee E20 onTemperature Measurement and is the direct responsibility of Subcommittee E20.08on Medical Thermometry.Current edition approved May 1, 2007. Published June 2007.
14、Originallyapproved in 1985. Last previous edition approved in 2001 as E 1061 01.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page
15、onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.2.10 visible start (VS), nthat temperature at which theliquid crystal first begins to reflect visible light.4. Requirements4.1 GeneralThermometers represented as co
16、mplying withthis specification shall meet all of the requirements specifiedherein.4.2 Temperature RangeThe liquid crystal forehead ther-mometer shall, as a minimum, meet all requirements of thisspecification over the temperature range of 32.0 to 38.0 C (90to 100 F). Some color must remain visible up
17、 to temperaturesof 39.5 C (103 F).4.3 ToleranceWhenever a temperature for a specific colorphenomenon (3.2.1) is measured, the maximum permissibledeviation is 60.6 C (61.0 F), when tested according to 5.2of this standard.4.4 SequencingThermal profiles of the liquid crystal for-mulations must be such
18、that: (1) no two readouts are the samecolor within the temperature range of red start to blue start atthe same time; and (2) within the temperature range of thedevice, color must be visible in at least one graphical repre-sentation at all times.4.5 Environment:4.5.1 Operating EnvironmentLiquid cryst
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME106120012007STANDARDSPECIFICATIONFORDIRECTREADINGLIQUIDCRYSTALFOREHEADTHERMOMETERS 直读 液晶 温度计 标准规范

链接地址:http://www.mydoc123.com/p-527836.html