ASTM E1044-1996(2011) 4375 Standard Specification for Glass Serological Pipets (General Purpose and Kahn)《血清玻璃吸管(一般用途和康氏)的标准规格》.pdf
《ASTM E1044-1996(2011) 4375 Standard Specification for Glass Serological Pipets (General Purpose and Kahn)《血清玻璃吸管(一般用途和康氏)的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1044-1996(2011) 4375 Standard Specification for Glass Serological Pipets (General Purpose and Kahn)《血清玻璃吸管(一般用途和康氏)的标准规格》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1044 96 (Reapproved 2011)Standard Specification forGlass Serological Pipets (General Purpose and Kahn)1This standard is issued under the fixed designation E1044; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the yea
2、r of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This specification covers glass
3、serological pipets, usedin measuring volumes of liquids.2. Referenced Documents2.1 ASTM Standards:2E438 Specification for Glasses in Laboratory ApparatusE542 Practice for Calibration of Laboratory VolumetricApparatusE671 Specification for Maximum Permissible Thermal Re-sidual Stress in Annealed Glas
4、s Laboratory ApparatusE694 Specification for Laboratory Glass Volumetric Appa-ratusE920 Specification for Commercially Packaged LaboratoryApparatusE921 Specification for Export Packaged Laboratory Appa-ratusE1133 Practice for Performance Testing of Packaged Labo-ratory Apparatus for United States Go
5、vernment Procure-mentsE1157 Specification for Sampling and Testing of ReusableLaboratory Glassware3. Classification3.1 Style and CapacityPipets covered by this specificationshall be of the following styles and capacities:3.1.1 Style IGeneral purpose top end.3.1.2 Style IICotton plugging top end.3.1.
6、3 Style IIICotton plugging top end, large tip opening.3.1.4 Capacities (mL)0.1; 0.1 (Kahn); 0.2; 0.2 (Kahn);0.25 (Kahn); 0.5; 0.60 (Kahn); 1.0; 2.0; 5.0; 10.0; and 25.0.4. General Requirements4.1 Borosilicate GlassBorosilicate glass for pipets shallconform to the glass requirements of Type 1, Class
7、A or B ofSpecification E438.4.2 CalibrationPipets shall be calibrated in accordancewith Practice E542 to deliver (TD) the intended capacity ofdistilled water at 20C when the last drop is blown out, exceptthe 0.25 mL Kahn pipet; this Kahn pipet shall have a clearungraduated space of not less than 63
8、mm between thelowermost graduation mark and the tip of the pipet. The pipetshall be filled about 10 mm above the capacity line. Removeany water on the outside of the tip by a downward wipe withfilter paper. Next, place the tip in contact with the wetted wallof a beaker and slowly lower the meniscus
9、to the capacity line.Do not remove any water remaining on the tip at this time.Delivery of the contents into a receiving vessel is made withthe tip in contact with the wall of the vessel. When the waterhas ceased to flow, the water remaining in the tip is then blownout with one firm puff with the ti
10、p in contact with the wall ofthe vessel, if possible. No after-drainage period is allowed.Capacity tolerances shall be within the limits given in Table 1.4.3 AnnealingThe maximum residual thermal stress shallbe such as to conform to Specification E671, except thattempered tips or tempered tops, or b
11、oth, may be supplied at theoption of the manufacturer. The tempered tip, when examinedin index oil that matches the refractive index of the glass beingused, shall have a temper between 75 and 220 nm.5. Design5.1 ShapeThe pipets shall be straight and of one-piececonstruction. Any cross section of a p
12、ipet taken in a planeperpendicular to the longitudinal axis shall be circular.5.2 Delivery TipsDelivery tips shall be made with agradual taper of 15 to 30 mm for capacities up to 5 mLinclusive, and 20 to 35 mm for 10 and 25 mL capacity pipets.The end of the tip shall be perpendicular to the longitud
13、inal1This specification is under the jurisdiction of ASTM Committee E41 onLaboratory Apparatus and is the direct responsibility of Subcommittee E41.01 onApparatus.Current edition approved Dec. 1, 2011. Published December 2011. Originallyapproved in 1985. Last previous edition approved in 2006 as E10
14、44 96 (2006).DOI: 10.1520/E1044-96R11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM Interna
15、tional, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.axis of the pipet. Sudden constriction at the orifice shall not beacceptable. The outside edge of the tip shall be bevelledslightly at the end, and the bevel shall be ground or firepol-ished.5.3 Zero Graduati
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME1044199620114375STANDARDSPECIFICATIONFORGLASSSEROLOGICALPIPETSGENERALPURPOSEANDKAHN 血清 玻璃 吸管 一般

链接地址:http://www.mydoc123.com/p-527803.html