《ASTM E102-1993(2003)e1 Standard Test Method for Saybolt Furol Viscosity of Bituminous Materials at High Temperatures《高温下沥青材料的赛氏厚油粘性的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E102-1993(2003)e1 Standard Test Method for Saybolt Furol Viscosity of Bituminous Materials at High Temperatures《高温下沥青材料的赛氏厚油粘性的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 102 93 (Reapproved 2003)e1Standard Test Method forSaybolt Furol Viscosity of Bituminous Materials at HighTemperatures1This standard is issued under the fixed designation E 102; the number immediately following the designation indicates the year oforiginal adoption or, in the case of r
2、evision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.e1NOTEThis test method was made SI-dominant in August 2003.1. Scope1.1 This test method covers the empirical
3、 procedures fordetermining the Saybolt Furol viscosities of bituminous mate-rials at specified temperatures between 120 and 240C (248and 464F).1.2 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.3 This standard does not purpo
4、rt to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. See 8.1.2. Referenced Documents2.1 ASTM Standa
5、rds:D 88 Test Method for Saybolt Viscosity2D 92 Test Method for Flash and Fire Points by ClevelandOpen Cup Tester3D 140 Practice for Sampling Bituminous Materials4E 1 Specification for ASTM Thermometers5E 11 Specification for Wire Cloth and Sieves for TestingPurposes63. Terminology3.1 Definitions:3.
6、1.1 Furolan acronym of “Fuel and road oils.”3.1.2 Saybolt Furol viscositythe corrected efflux time inseconds of 60 mL of sample flowing through a calibrated Furolorifice under specified conditions. The viscosity value isreported in Saybolt Furol seconds, abbreviated SFS, at aspecified temperature.4.
7、 Summary of Test Method4.1 The efflux time in seconds of 60 mL of sample, flowingthrough a calibrated orifice, is measured under carefullycontrolled conditions. The time is corrected by an orifice factorand reported as the viscosity of the sample at that temperature.5. Significance and Use5.1 This t
8、est method is useful in characterizing certainbituminous materials, as one element in establishing unifor-mity of shipments and sources of supply.5.2 This test method is an extension of Test Method D 88.6. Apparatus6.1 Saybolt Furol Viscometer and Bath, as shown anddescribed in Test Method D 88, Fig
9、. 1 and Annex 1. Anexternal heater may also be used, but if so, it shall be more than51 mm (2 in.) from the viscometer. An aluminum-block,constant-temperature bath is also acceptable, and no stirringdevice is required with this type of bath.6.2 Displacement Ring, as shown in Fig. 1, constructed ofth
10、e same corrosion-resistant metal as the viscometer.6.3 CoverA metal cover for the viscometer, cylindricalwith a flat top, approximately 57 mm (214 in.) in diameter and7mm(14 in.) deep (Note 1). One hole slightly larger than thediameter of a viscosity thermometer shall be drilled in thecenter of the
11、cover, and two smaller holes to permit the verticalrods of the displacement ring to pass through the cover.NOTE 1The cover of a 90-mL (3-oz) Gill-style ointment box fulfillsthese requirements.6.4 Thermometer Support, as shown in Test Method D 88,Fig. 3.6.5 Saybolt Viscosity Thermometers, as listed i
12、n Table 1, forreading the temperature of the sample. Each thermometer shallconform to the requirements listed in Specification E 1 for thatASTM Thermometer Number.6.6 Bath ThermometersSaybolt Viscosity thermometers,or any other temperature-indicating means of equivalent accu-racy.6.7 Sieve, 850-m (N
13、o. 20), conforming to the requirementsof Specification E 11.6.8 Receiving Flask, as shown in Test Method D 88, Fig. 5.1This test method is under the jurisdiction of ASTM Committee D08 on Roofingand Waterproofing and is the direct responsibility of Subcommittee D08.05 onSolvent-Bearing Bituminous Com
14、pounds for Roofing and Waterproofing.Current edition approved Aug. 10, 2003. Published August 2003. Originallyapproved in 1954. Last previous edition approved in 1997 as E 102 93 (1997).2Annual Book of ASTM Standards, Vol 04.04.3Annual Book of ASTM Standards, Vol 05.01.4Annual Book of ASTM Standards
15、, Vol 04.03.5Annual Book of ASTM Standards, Vol 14.03.6Annual Book of ASTM Standards, Vol 14.02.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.6.9 Timer, graduated in fifths or tenths of a second, andaccurate to within 0.1 % when te
16、sted over a 60-min interval.Electric timers are acceptable if operated on a controlledfrequency circuit.6.10 Hot Plate, electric, approximately 200 mm (8 in.) indiameter, with a three-heat switch, rated at 1200 W at the highheat setting and 500 to 600 W at the medium heat setting.7. Sampling7.1 Samp
17、le the material in accordance with Practice D 140.8. Preparation of Apparatus8.1 Clean the viscometer thoroughly with xylene, removeall solvent from the viscometer and its gallery, and dry well.Clean the displacement ring and receiving flask in the samemanner. Xylene is a toxic and flammable solvent
18、; all workingareas shall be efficiently hooded and kept free of sparks andopen flames. If the viscometer is hot, vaporization of xylenecan be reduced by filling the tube rapidly and immediatelyallowing it to flow out through the orifice. A wooden toothpickmay be useful in cleaning the orifice.NOTE 2
19、The viscometer may be kept clean by filling with cylinder oilimmediately after each test and allowing the oil to remain in theviscometer for several minutes before draining and cleaning with xyleneas described above. If desired, the viscometer may be kept filled withcylinder oil between runs, draini
20、ng and cleaning with xylene just beforeeach test.8.2 Set up the viscometer and bath in an area where theywill not be exposed to drafts or rapid changes in air tempera-ture, and dust or vapors that might contaminate a sample.8.3 Place the receiving flask beneath the viscometer so thatthe graduation m
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME10219932003E1STANDARDTESTMETHODFORSAYBOLTFUROLVISCOSITYOFBITUMINOUSMATERIALSATHIGHTEMPERATURES 高温

链接地址:http://www.mydoc123.com/p-526841.html