1、Designation: D8016 15Standard Test Method forSilica, Precipitated, HydratedSears Number1This standard is issued under the fixed designation D8016; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number
2、in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method is used to determine the number ofsilanol groups on the surface of silica by titration according toa method as developed by S
3、ears. This test method is suitablefor characterizing rubber-grade silicas.1.2 UnitsThe values stated in SI units are to be regardedas the standard. No other units of measurement are included inthis standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated w
4、ith its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D6738 Test Method for Precipitated SilicaVolatile Con-tent3. Summ
5、ary of Test Method3.1 An ion exchange reaction in silica is possible based onthe acidic character of the surface silanol groups. According toSears,3it is possible to determine the surface area of colloidalsilica on the basis of this ion exchange mechanism, aftercertain preliminary treatments, by tit
6、ration with a basic solu-tion. The initial preliminary treatment step consists of exposureof the silica to a sufficiently concentrated solution of sodiumchloride (NaCl). After this the suspension of silica and NaCl isback-titrated with sodium hydroxide solution.3.2 A 1.5 g sample of silica is weighe
7、d into a 250 cm3beaker containing 150 cm3NaCl solution adjusted to pH 3. Thesuspension is stirred for 3 min and brought to 25C. Thesuspension is titrated first to pH 4 and then to pH 9 using asodium hydroxide solution (c = 0.1 mol/dm3). The volume ofsodium hydroxide solution that is reacted between
8、pH 4 and pH9 is calculated and corrected with the volatile matter deter-mined according to Test Method D6738. The consumption ofsodium hydroxide solution minus the blank reading withoutsilica is defined as the Sears Number given in cm3/1.5 g. Thespecific consumption of sodium hydroxide solution in a
9、 silicasuspension depends primarily on the silica surface area, thedensity of the silanol groups, and the degree of hydrophobicity.4. Significance and Use4.1 The rubber-filler interaction needed in silica technologyfor the rubber industry is based on the use of silane-couplingagents that react with
10、the silanol groups on the surface of thesilica during the processing step called silanization. Silane-coupling agents are multifunctional molecules able to createmolecular bridges between the elastomer or rubber matrix andthe silica surface.5. Apparatus5.1 Precision Balance, 0.01 g sensitivity.5.2 A
11、utomatic Titration Apparatus, capable of performing avolumetric endpoint titration based on pH, as well as equippedwith data storage and calculation modules.45.2.1 Burette, to titrate hydrochloric acid (c = 0.1 mol/dm3),and5.2.2 Burette, to titrate sodium hydroxide standard solution(c = 0.1 mol/dm3)
12、.5.3 pH electrode.5.4 Printer (optional).5.5 Beakers, glass, 250 cm3.5.6 Laboratory Grinder, for example, electro-mechanical.5.7 Wire Mesh Sieve, 75 m (200 mesh).5.8 Thermostated water bath.5.9 Titration Beaker, 150 cm3for determination of the actualconcentration of the sodium hydroxide standard sol
13、ution.5.10 Analytical Balance, 0.1 mg sensitivity.5.11 Magnetic Stirrer with Stir Bar.1This test method is under the jurisdiction of ASTM Committee D11 on Rubberand is the direct responsibility of Subcommittee D11.20 on Compounding Materialsand Procedures.Current edition approved Nov. 1, 2015. Publi
14、shed December 2015. DOI:10.1520/D8016-15.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3G. W. Sears, Anal.
15、Chem., 1981-1983, 1956.4Appropriate devices are commercially available.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15.12 Graduated Cylinder, 250 cm3.5.13 Beaker, glass, 2 dm3.5.14 Volumetric Flask, 2dm3.6. Reagents and Materials6.1
16、 Purity of ReagentsReagent-grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents conform to the specifications of the Committee onAnalytical Reagents of the American Chemical Society wheresuch specifications are available.5Other grades may be used,pro
17、vided it is first ascertained that the reagent is of sufficientlyhigh purity to permit its use without lessening the accuracy ofthe determination.6.2 NaCl SolutionDissolve 400 g analytical grade NaCl inapproximately 1.75 dm3deionized water ina2dm3beaker.Adjust the solution to pH 3 (60.1) with hydroc
18、hloric acid, c =1 mol/dm3, and transfer the solution toa2dm3volumetricflask. When the temperature has reached 25C, fill the volu-metric flask to the calibration mark and mix well using thestirrer bar and the magnetic stirrer.6.3 Hydrochloric Acid (HCl), 0.1 mol/dm3.6.4 Sodium Hydroxide Standard Solu
19、tion (NaOH), 0.1 mol/dm3.6.5 Deionized Water.6.6 Buffer Solutions, pH of 4, 7, and 9.6.7 Potassium Hydrogen Phthalate, primary standard.7. Procedure7.1 Grind an appropriate quantity of silica sample in alaboratory grinder for 60 s. Approximately 6 to8garerecommended for a determination of the Sears
20、Number induplicate or in triplicate, respectively.7.2 Pass ground sample (see 7.1) through a wire mesh sieve75 m (200 mesh). This can be accomplished manually ormechanically. Discard fraction retained on sieve. The fraction75 m (200 mesh) is used for the determination of the SearsNumber.7.3 Determin
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD801620154363STANDARDTESTMETHODFORSILICAPRECIPITATEDHYDRATEDX2014SEARSNUMBER 沉淀 水合 二氧化硅 标准 试验 方法

链接地址:http://www.mydoc123.com/p-526640.html