ASTM D7083-2016 red 9060 Standard Practice for Determination of Monomeric Plasticizers in Poly (Vinyl Chloride) (PVC) by Gas Chromatography《采用气相色谱法测定聚氯乙烯 (PVC) 中单体增塑剂的标准实施规程》.pdf
《ASTM D7083-2016 red 9060 Standard Practice for Determination of Monomeric Plasticizers in Poly (Vinyl Chloride) (PVC) by Gas Chromatography《采用气相色谱法测定聚氯乙烯 (PVC) 中单体增塑剂的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D7083-2016 red 9060 Standard Practice for Determination of Monomeric Plasticizers in Poly (Vinyl Chloride) (PVC) by Gas Chromatography《采用气相色谱法测定聚氯乙烯 (PVC) 中单体增塑剂的标准实施规程》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7083 04 (Reapproved 2010)1D7083 16Standard Practice forDetermination of Monomeric Plasticizers in Poly (VinylChloride) (PVC) by Gas Chromatography1This standard is issued under the fixed designation D7083; the number immediately following the designation indicates the year oforiginal a
2、doption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1 NOTEReapproved with editorial changes in July 2010.1. Scope*1.1 This practice p
3、rovides for the separation and identification of monomeric plasticizers in poly (vinyl chloride) (PVC)compounds by gas chromatography (GC).1.2 The text of this practice references notes and footnotes which provide explanatory material. These notes and footnotes(excluding those in Tables and Figures)
4、 shall not be considered as requirements of this standard.1.3 Test Method D2124 is an alternative infrared procedure.1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.5 This standard does not purport to address all of the
5、safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.NOTE 1There is no known ISO equivalent to this standard.2. Referenced Docu
6、ments2.1 ASTM Standards:2D883 Terminology Relating to PlasticsD1600 Terminology for Abbreviated Terms Relating to PlasticsD2124 Test Method for Analysis of Components in Poly(Vinyl Chloride) Compounds Using an Infrared SpectrophotometricTechniqueD3465 Test Method for Purity of Monomeric Plasticizers
7、 by Gas ChromatographyD7823 Test Method for Determination of Low Level, Regulated Phthalates in Poly (Vinyl Chloride) Plastics by ThermalDesorptionGas Chromatography/Mass SpectrometryE355 Practice for Gas Chromatography Terms and RelationshipsE594 Practice for Testing Flame Ionization Detectors Used
8、 in Gas or Supercritical Fluid ChromatographyIEEE/ASTM SI-10 Practice for Use of the International System of Units (SI), the Modernized Metric System3. Terminology3.1 Definitions:3.1.1 For definition of plastic terms used in this standard, see Terminologies D883 and D1600.3.2 For units, symbols, and
9、 abbreviations used in this standard refer to Practices E594, E355, or IEEE/ASTM SI-10.3.3 Abbreviations:3.3.1 DOABis (2-ethylhexyl) adipate3.3.2 DBPDibutyl phthalate3.3.3 DOPBis (2-ethylhexyl) phthalate3.3.4 FTIRFourier Transform Infrared Spectroscopy1 This test method is under the jurisdiction of
10、ASTM Committee D20 on Plastics and is the direct responsibility of Subcommittee D20.70 on Analytical Methods.Current edition approved July 1, 2010May 1, 2016. Published October 2010May 2016. Originally approved in 2004. Last previous edition approved in 20042010 asD7083 - 04.D7083 - 04(2010)1. DOI:
11、10.1520/D7083-04R10E01.10.1520/D7083-16.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not
12、an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate.
13、 In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.3.
14、5 GCGas Chromatography3.3.6 GC/MSGas Chromatography/Mass Spectrometry3.3.7 GPCGel Permeation Chromatography3.3.8 HPLCHigh Performance Liquid Chromatography3.3.9 PVCPoly (Vinyl Chloride)3.3.10 TCPTricresyl phosphate3.3.11 TOPTris (2-ethylhexyl) phosphate3.3.12 TOTMTrioctyl trimellitate4. Summary of T
15、est Method4.1 A PVC sample is extracted in accordance with Test Method D2124 and the extract residue is re-dissolved in a solvent. Theresulting solution is then analyzed by GC to determine the identity of each plasticizer component. The plasticizer components areidentified by retention time, or chro
16、matographic fingerprint, or both.5. Significance and Use5.1 Separation and identification of plasticizer components in PVC is necessary to correlate performance properties withpolymer composition. This test method provides a means of determining monomeric plasticizers including adipates, azelates,be
17、nzoates, citrates, phthalates, sebacates, and trimellitates.5.2 Other methods successfully used to analyze plasticizers are column chromatography, HPLC, GPC, FTIR, and GC/MS.5.3 This method is not applicable to plasticizers with molecular weights over 700 g/mol including epoxidized soybean oil andpo
18、lymeric plasticizers.6. Interferences6.1 Retention times for GC are dependent on several variables and it is quite possible to have two or more components withidentical retention times. The GC operator shouldshall take the necessary steps to insure that adequate separation of the plasticizercomponen
19、ts is achieved.6.2 A source of interference can be from solvent impurities. Run a solvent blank prior to analysis of an extract.7. Apparatus7.1 Gas chromatograph equipped with a flame ionization detector and capable of operating in the 250 to 350C range.7.2 A capillary or packed gas chromatographic
20、column capable of operating in the 250 to 350C range such as a 30-metre 100% poly (dimethylsiloxane) phase fused silica open tubular capillary column; 0.32 mm ID with a 0.25 m film thickness, or astainless steel packed column; 1.83 m long with an outside diameter of 6.4 mm, and filled with Chromosor
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD70832016RED9060STANDARDPRACTICEFORDETERMINATIONOFMONOMERICPLASTICIZERSINPOLYVINYLCHLORIDEPVCBYGASCHROMATOGRAPHY

链接地址:http://www.mydoc123.com/p-524451.html