《ASTM D6634-2001(2006) Standard Guide for the Selection of Purging and Sampling Devices for Groundwater Monitoring Wells《地下水监测井用净化和取样选择的标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6634-2001(2006) Standard Guide for the Selection of Purging and Sampling Devices for Groundwater Monitoring Wells《地下水监测井用净化和取样选择的标准指南》.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 6634 01 (Reapproved 2006)Standard Guide forthe Selection of Purging and Sampling Devices for Ground-Water Monitoring Wells1This standard is issued under the fixed designation D 6634; the number immediately following the designation indicates the year oforiginal adoption or, in the cas
2、e of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide describes the characteristics and operatingprinciples of purging and sampling d
3、evices available for use inground-water monitoring wells and provides criteria for select-ing appropriate devices for specific applications. The selecteddevice(s) should be capable of purging the well and providingvalid representative samples of ground water and any includeddissolved constituents. T
4、he scope does not include proceduresfor purging or collecting samples from monitoring wells,sampling devices for non-aqueous phase liquids, diffusion-typesampling devices or sampling from devices other than moni-toring wells.1.2 This guide reviews many of the most commonly useddevices for purging an
5、d sampling ground-water monitoringwells. The practitioner must make every effort to ensure thatthe purging and sampling methods used, whether or not theyare addressed in this guide, are adequate to satisfy themonitoring objectives at each site.1.3 This guide offers an organized collection of informa
6、tionor a series of options and does not recommend a specific courseof action. This document cannot replace education or experi-ence and should be used in conjunction with professionaljudgement. Not all aspects of this guide may be applicable inall circumstances. This ASTM standard is not intended to
7、represent or replace the standard of care by which the adequacyof a given professional service must be judged, nor should thisdocument be applied without consideration of the many uniqueaspects of a project. The word “Standard” in the title of thisdocument means only that the document has been appro
8、vedthrough the ASTM consensus process.1.4 This standard does not purport to address all of thesafety problems, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory li
9、mitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 5088 Practices for Decontamination of Field EquipmentUsed at Waste SitesD 6452 Guide for Purging Methods for Wells Used forGround-Water Quality Investigations3. Summary of Guide3.1 The primary objective of ground-water sampling pro-
10、grams is to collect representative samples of ground water.Depending on the purging and sampling protocol, this mayrequire that the well is purged of all stagnant water, or untilpre-determined purging criteria are met. Therefore, device(s)selected for use in ground-water sampling programs must becap
11、able of purging the well as needed and/or delivering to thesurface, a sample representative of in-situ ground-water con-ditions. A number of factors can influence whether or not aparticular sample or set of samples is representative, and one ofthe significant elements of sample collection protocols
12、is thesampling mechanism (1, 2, 3).33.2 In selecting a purging and/or sampling device for use ina ground-water monitoring well, a number of factors must beconsidered. Among these are 1) outside diameter of the device;2) materials from which the device and associated equipmentare made; 3) overall imp
13、act of the device on ground-watersample integrity with respect to the analytes of interest; 4)ability to control the discharge rate of the device; 5) depth towater; 6) ease of operation and servicing; 7) reliability anddurability of the device; 8) portability of the device and1This guide is under th
14、e jurisdiction ofASTM Committee D18 on Soil and Rockand is the direct responsibility of Subcommittee D18.21 on Ground Water andVadose Zone Monitoring.Current edition approved July 1, 2006. Published July 2006. Originally approvedin 2001. Last previous edition approved in 2001 as D 6634 01.2For refer
15、enced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The boldface numbers in parentheses refer to a list of references at t
16、he end ofthis standard.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.required accessory equipment, if applicable; 9) other opera-tional limitations of the device; and 10) initial and operatingcost of the device and accessory equipm
17、ent. Based on theseconsiderations, each of the devices available for purging and/orsampling ground water from monitoring wells has its ownunique set of advantages and limitations.4. Significance and Use4.1 Appropriate purging and sampling equipment must beused to ensure that samples collected from m
18、onitoring wellsrepresent the ground-water chemistry of the desired waterbearing zone.4.2 This guide is intended to be a common reference forpurging and sampling devices. It can be applied to ground-water quality sampling from monitoring wells used for ground-water contamination evaluation, water sup
19、ply characterization,and research.4.3 This guide includes a number of general guidancestatements that are not directly related to the operating prin-ciples or characteristics of the equipment. These statements aregiven to assist the user in understanding the application of theequipment, which could
20、ultimately affect the selection process.5. Objectives of Well Purging and Sampling5.1 The primary objective of ground-water sampling pro-grams is to obtain samples that are representative of existingground-water conditions retaining the physical and chemicalproperties of the ground water in a specif
21、ic water-bearingzone.46. Criteria for Selection of Purging and SamplingDevices6.1 When selecting purging and/or sampling device(s), anumber of criteria must be evaluated as discussed below. Basedon these criteria, each device has a unique set of advantagesand limitations that define suitability to s
22、ite-specific applica-tions.6.2 Outside Diameter of the Device If the well(s) to bepurged and sampled is (are) already in place, the initialconsideration in selecting a device is whether or not the well(s)will accommodate the device. It is important to consider thatthe wells may not be plumb, may hav
23、e constrictions in thecasing (i.e. at joints), or may contain other obstructions thatmake the effective inside diameter of the well smaller than theinside diameter of the casing. Alternately, if the monitoringwells are not in place, it may be more prudent to first select adevice that meets the requi
24、rements of the sampling programand then select the size of the casing to be used in the wells.The smaller the inside diameter of the well, the more limitedthe selection of devices becomes. The majority of ground-water monitoring wells installed at various types of sites aresmall-diameter wells, or w
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD663420012006STANDARDGUIDEFORTHESELECTIONOFPURGINGANDSAMPLINGDEVICESFORGROUNDWATERMONITORINGWELLS

链接地址:http://www.mydoc123.com/p-523108.html